DSpace/Manakin Repository

Equalização do desvio padrão do campo elétrico em uma câmara de reverberação compacta.

Mostrar registro simples

dc.creator.ID PEDRO, H .J. G. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/9620256708244128 pt_BR
dc.contributor.advisor1 FONTGALLAND, Glauco.
dc.contributor.advisor1ID FONTGALLAND, G. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4256595317953538 pt_BR
dc.contributor.advisor2 RODRIGUES, Raquel Aline Araújo.
dc.contributor.advisor2ID RODRIGUES, R. A. A. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/4655728179608279 pt_BR
dc.contributor.referee1 QUEIROZ, Wamberto José Lira de.
dc.contributor.referee2 CARVALHO, Joabson Nogueira de.
dc.description.resumo A câmara de reverberação é um ambiente de testes utilizado para avaliar a compatibilidade eletromagnética de um equipamento eletrônico. No interior da câmara de reverberação háumvolume chamado de zona de campo uniforme, onde o equipamento sob teste é posicionado. Nesse volume, o valor do desvio padrão do campo elétrico não pode ultrapassar 3 dB. A posição do equipamento sob teste pode elevar desvio padrão do campo elétrico no interior da zona de campo uniforme. Nesse sentido, é importante verificar, equalizar e reduzir os valores do desvio padrão de cada componente do campo elétrico. O desvio padrão pode ser utilizado como métrica de desempenho, porém para avaliar o desempenho da câmara de reverberação e dos agitadores é necessário escolher um conjunto de métricas que possam caracterizar diferentes aspectos do campo elétrico no interior da câmara, permitindo investigar a convergência dos resultados. Cada métrica de desempenho é obtida por meio da medição do campo elétrico em um ou mais vértices da zona de campo uniforme. Neste trabalho, foi empregado um conjunto de métricas de desempenho mais comuns na literatura, como: coeficiente de anisotropia, coeficiente de não-homogeneidade, desvio padrão e fator de qualidade. Os resultados foram obtidos na faixa de 700 MHz a 3 GHz, permitindo comprovar que a redução da área útil, a introdução de rugosidade e o emprego de ângulos de abertura nas pás do agitador contribuem para o aumento da faixa de operação (em 150 MHz) da câmara de reverberação, redução e equalização do desvio padrão (na faixa de frequências de 1,35 GHz a 3 GHz) no interior da zona de campo uniforme, permitindo que o equipamento sob teste possa ser testado independente de sua posição. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Equalização do desvio padrão do campo elétrico em uma câmara de reverberação compacta. pt_BR
dc.date.issued 2017-12-22
dc.description.abstract A reverberation chamber is a test environment used to evaluate the electromagnetic compatibility of electronic equipment. Inside the Reverb chamber there is a volume called the uniform field zone where the equipment under test is positioned. In this volume the value of the standard deviation of the electric field can not exceed 3 dB. The position of the equipment under test may raise the standard deviation of the electric field within the uniform field zone. In this sense, it is important to verify, equalize and reduce the values of the electric field component standard. The standard deviation can be used as a performance metric, but to evaluate the performance of the reverberation chamber and the stirrers it is necessary to choose a set of metrics that can characterize different aspects of the electric field without interior of the chamber, allowing to investigate a convergence of the results. Each performance metric is obtained by measuring the electric field at one or more vertices of the uniform field zone. In this work, we used a set of performance metrics more common in the literature as: coefficient of anisotropy, coefficient of non-homogeneity, standard pattern and quality factor. The results were obtained in the range of 700 MHz to 3 GHz, allowing to prove that the reduction of the working area, the introduction of roughness and the use of opening angles in the blades of the agitator contribute to the increase of the operating range (in 150 MHz) of the reverberation chamber, reduction and equalization of the standard deviation (from 1.35 GHz to 3 GHz) within the uniform field zone, allowing the equipment under test to be tested regardless of its position. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187
dc.date.accessioned 2021-07-22T16:51:43Z
dc.date.available 2021-07-22
dc.date.available 2021-07-22T16:51:43Z
dc.type Dissertação pt_BR
dc.subject Estágio em Engenharia Elétrica pt_BR
dc.subject Câmara de reverberação pt_BR
dc.subject Campo elétrico - anisotropia pt_BR
dc.subject Equalização do desvio padrão pt_BR
dc.subject Agitador de modos pt_BR
dc.subject Anisotropia do campo elétrico pt_BR
dc.subject Equações de Maxwell pt_BR
dc.subject Cavidade retangular ressonante pt_BR
dc.subject Motor de passo pt_BR
dc.subject Internship in Electrical Engineering pt_BR
dc.subject Reverberation chamber pt_BR
dc.subject Electric field - anisotropy pt_BR
dc.subject Standard deviation equalization pt_BR
dc.subject Mode shaker pt_BR
dc.subject Electric field anisotropy pt_BR
dc.subject Maxwell's Equations pt_BR
dc.subject Resonant rectangular cavity pt_BR
dc.subject Stepper motor pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator PEDRO, Haslan José Gonçalves.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Standard deviation equalization of the electric field in a compact reverb chamber. pt_BR
dc.identifier.citation PEDRO, Haslan José Gonçalves. Equalização do desvio padrão do campo elétrico em uma câmara de reverberação compacta. 2017. 81f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187 pt_BR