dc.description.resumo |
A câmara de reverberação é um ambiente de testes utilizado para avaliar a compatibilidade
eletromagnética de um equipamento eletrônico. No interior da câmara de
reverberação háumvolume chamado de zona de campo uniforme, onde o equipamento
sob teste é posicionado. Nesse volume, o valor do desvio padrão do campo elétrico
não pode ultrapassar 3 dB. A posição do equipamento sob teste pode elevar desvio
padrão do campo elétrico no interior da zona de campo uniforme. Nesse sentido, é importante
verificar, equalizar e reduzir os valores do desvio padrão de cada componente
do campo elétrico. O desvio padrão pode ser utilizado como métrica de desempenho,
porém para avaliar o desempenho da câmara de reverberação e dos agitadores é necessário
escolher um conjunto de métricas que possam caracterizar diferentes aspectos do
campo elétrico no interior da câmara, permitindo investigar a convergência dos resultados.
Cada métrica de desempenho é obtida por meio da medição do campo elétrico
em um ou mais vértices da zona de campo uniforme. Neste trabalho, foi empregado
um conjunto de métricas de desempenho mais comuns na literatura, como: coeficiente
de anisotropia, coeficiente de não-homogeneidade, desvio padrão e fator de qualidade.
Os resultados foram obtidos na faixa de 700 MHz a 3 GHz, permitindo comprovar
que a redução da área útil, a introdução de rugosidade e o emprego de ângulos de
abertura nas pás do agitador contribuem para o aumento da faixa de operação (em 150
MHz) da câmara de reverberação, redução e equalização do desvio padrão (na faixa de
frequências de 1,35 GHz a 3 GHz) no interior da zona de campo uniforme, permitindo
que o equipamento sob teste possa ser testado independente de sua posição. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Engenharia Elétrica e Informática - CEEI |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Elétrica. |
pt_BR |
dc.title |
Equalização do desvio padrão do campo elétrico em uma câmara de reverberação compacta. |
pt_BR |
dc.date.issued |
2017-12-22 |
|
dc.description.abstract |
A reverberation chamber is a test environment used to evaluate the electromagnetic
compatibility of electronic equipment. Inside the Reverb chamber there is a volume
called the uniform field zone where the equipment under test is positioned. In this
volume the value of the standard deviation of the electric field can not exceed 3 dB. The
position of the equipment under test may raise the standard deviation of the electric
field within the uniform field zone. In this sense, it is important to verify, equalize and
reduce the values of the electric field component standard. The standard deviation can
be used as a performance metric, but to evaluate the performance of the reverberation
chamber and the stirrers it is necessary to choose a set of metrics that can characterize
different aspects of the electric field without interior of the chamber, allowing to investigate
a convergence of the results. Each performance metric is obtained by measuring
the electric field at one or more vertices of the uniform field zone. In this work, we used
a set of performance metrics more common in the literature as: coefficient of anisotropy,
coefficient of non-homogeneity, standard pattern and quality factor. The results were
obtained in the range of 700 MHz to 3 GHz, allowing to prove that the reduction of
the working area, the introduction of roughness and the use of opening angles in the
blades of the agitator contribute to the increase of the operating range (in 150 MHz) of
the reverberation chamber, reduction and equalization of the standard deviation (from
1.35 GHz to 3 GHz) within the uniform field zone, allowing the equipment under test
to be tested regardless of its position. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187 |
|
dc.date.accessioned |
2021-07-22T16:51:43Z |
|
dc.date.available |
2021-07-22 |
|
dc.date.available |
2021-07-22T16:51:43Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Estágio em Engenharia Elétrica |
pt_BR |
dc.subject |
Câmara de reverberação |
pt_BR |
dc.subject |
Campo elétrico - anisotropia |
pt_BR |
dc.subject |
Equalização do desvio padrão |
pt_BR |
dc.subject |
Agitador de modos |
pt_BR |
dc.subject |
Anisotropia do campo elétrico |
pt_BR |
dc.subject |
Equações de Maxwell |
pt_BR |
dc.subject |
Cavidade retangular ressonante |
pt_BR |
dc.subject |
Motor de passo |
pt_BR |
dc.subject |
Internship in Electrical Engineering |
pt_BR |
dc.subject |
Reverberation chamber |
pt_BR |
dc.subject |
Electric field - anisotropy |
pt_BR |
dc.subject |
Standard deviation equalization |
pt_BR |
dc.subject |
Mode shaker |
pt_BR |
dc.subject |
Electric field anisotropy |
pt_BR |
dc.subject |
Maxwell's Equations |
pt_BR |
dc.subject |
Resonant rectangular cavity |
pt_BR |
dc.subject |
Stepper motor |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
PEDRO, Haslan José Gonçalves. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Standard deviation equalization of the electric field in a compact reverb chamber. |
pt_BR |
dc.identifier.citation |
PEDRO, Haslan José Gonçalves. Equalização do desvio padrão do campo elétrico em uma câmara de reverberação compacta. 2017. 81f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/20187 |
pt_BR |