Uso de tanque de cimento amianto como alternativa para medir evaporação.

Mostrar registro simples

dc.creator.ID SILVA, A. S. L. pt_BR
dc.contributor.advisor1 LEITÃO, Mário de Miranda Vilas Boas Ramos.
dc.contributor.advisor1ID LEITÃO, M. M. V. B. R. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/7305189524186801 pt_BR
dc.contributor.referee1 SOUSA, Francisco de Assis Salviano de.
dc.contributor.referee2 AMORIM NETO, Malaquias da Silva.
dc.description.resumo Esta pesquisa foi conduzida na Estação Meteorológica do Departamento de Ciências Atmosféricas do CCT da Universidade Federal da Paraíba - UFPB Campus II, no município de Campina Grande - PB (7°13'32" S; 35° 54'15" W; alt. 518,34 m), no período de 15 de novembro de 1999 à 01 de abril de 2000, tendo como principal objetivo avaliar a performance de tanques de cimento amianto como uma alternativa de substituição do tanque Classe A para medir evaporação. O experimento foi realizado em quatro etapas distintas, usando-se quatro tanques, sendo dois Classe A operados de acordo com os padrões da OMM e dois de cimento amianto (caixas d'água de 500 litros), nos quais foram construídos poços tranquilizadores com cano de PVC de 100 mm de diâmetro, para ter-se as mesmas condições de leitura do Classe A. Nas três primeiras fases do experimento os tanques foram operados no mesmo nível em relação ao solo: um Classe A (Cl) e um de cimento amianto (Al) em área gramada e os outros dois tanques C2 e A2 em uma área quase sem vegetação. O tanque A2 em cada fase foi operado de forma diferente, na primeira fase com uma lâmina d'água de 60cm, na segunda com lâmina de 40cm de água e 20cm de areia, na terceira com uma lâmina de 20cm de água e 40cm de areia, já na última fase o mesmo foi transferido para a área gramada, enterrado 45cm e operado com lâmina de 60cm. Também durante três fases experimentais foram efetuadas medidas de temperatura e umidade do ar, do saldo de radiação, da velocidade e direção do vento, bem como de temperatura da água nos quatro tanques. Para obtenção destas medidas utilizou-se um Micrologger 2IX, o qual foi programado para efetuar leituras a cada segundo e fazer médias a cada dez minutos, vinte e quatro horas por dia. Ao comparar-se as medidas obtidas nos dois tipos de tanques, verificou-se que nas três primeiras fases houve maior evaporação nos tanques de cimento amianto e que na primeira fase este índice chegou a erca de 16%. Já na última fase houve uma evaporação um pouco maior no tanque Classe A. Percebeu-se também que na medida em que a umidade do ar foi aumentando houve uma tendência de aproximação das medidas de evaporação. Quanto a temperatura, os tanques Classe A apresentaram-se sempre mais aquecidos do que os tanques de cimento amianto no período diurno, enquanto no período noturno ocorreu o inverso, os tanques de cimento amianto apresentaram-se mais aquecidos que os tanques Classe A. Observou-se ainda que o tanque Classe A resfriou-se muito rápido e aqueceu-se também muito rápido, e que em média sua água esteve apenas mais aquecida do que a do tanque de cimento amianto em cerca de sete horas durante o dia. As estimativas de evaporação pelo método Penman sobrestimaram os valores medidos nas três fases experimentais, apresentando uma maior defasagem em relação ao tanque Classe A, 32,2; 37,4 e 38,9%, respectivamente. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM METEOROLOGIA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Meteorologia. pt_BR
dc.subject.cnpq Ciências atmosféricas. pt_BR
dc.title Uso de tanque de cimento amianto como alternativa para medir evaporação. pt_BR
dc.date.issued 2000-10-31
dc.description.abstract This research was conducted at the Meteorological Station of the Department of Atmospheric Sciences of CCT of the Federal University of Paraiba - UFPB, Campus II, in the municipal district of Campina Grande - PB (7°13'32 " S; 35° 54*15 " W; alt. 518,34 m), during the period of November 15, 1999 to April 01, 2000, with the main objective of evaluating the performance of pans of cement amianthus as a substitution alternative of the pan Class A, to measure evaporation. The experiment was accomplished in four different stages, using four pans, two Class A pans being operated in agreement with the standards of WMO and two of cement amianthus (water pans of 500 liters), where still wells were built with pipe of PVC of lOOmm, to have the same conditions of the Class A pan. In the first three phases of the experiment the pans were operated at the same levei in relation to the soil: one of Class A (Cl) and one of cement amianthus (Al) in the area cevened with grass and the other two pans C2 and A2 in an area almost without vegetation. The pan A2 in each phase was operated in a different way, in the first phase with a layer of water of 60cm, in the second phase with a layer of 40cm of water and 20cm of sand, in the third phase with a layer of 20cm of water and 40cm of sand, already in the last phase, the same was transferred to the area covered with grass, buried 45cm and operated with a layer of 60cm. Also during the three experimental phases air temperature and humidity, net radiation, speed and direction the wind, as well as the temperature of the water in the four pans were measured. For obtaining these measurements a Micrologger 21X was used and is programmed to make readings to every second and to make averages every ten minutes, twenty-four hours a day. When comparing the values obtained in the two types of pans, it was verified that there was larger evaporation in the pans of cement amianthus in the first three phases and that in the first phase this index the attained 16%. Already in the last phase there was an evaporation a little larger in the pan Class A. It was also noticed that with the increase of humidity there was a tendency of increased evaporation. The temperature of the Class A pans was always warmer than the pans of cement amianthus during the day, while in the night period it happened the inverse, the pans of cement amianthus got heated up more than the Class A pans. It was observed that the Class A pan cooled rapidly and also became warm very fast, and that on the average its water was slightly warmer than that of the pan of cement amianthus for a period of seven hours during the day. The evaporation estimates by the Penman method superestimated the values measured in the three experimental phases, presented a larger lag in relation to the pan Class A, 32,2; 37,4 and 38,9%, respectively. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2096
dc.date.accessioned 2018-10-30T18:08:32Z
dc.date.available 2018-10-30
dc.date.available 2018-10-30T18:08:32Z
dc.type Dissertação pt_BR
dc.subject Tanque de cimento amianto pt_BR
dc.subject Evaporação pt_BR
dc.subject Medidas de evaporação pt_BR
dc.subject Estimativas de evaporação pt_BR
dc.subject Balanço de energia pt_BR
dc.subject Tanque classe A pt_BR
dc.subject Método Penman pt_BR
dc.subject Evaporation Estimates pt_BR
dc.subject Evaporation measures pt_BR
dc.subject Asbestos cement tank pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Andréa Socorro Lima.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Use of asbestos cement tank as an alternative to measure evaporation. pt_BR
dc.description.sponsorship Capes pt_BR
dc.identifier.citation SILVA, Andréa Socorro Lima. Uso de tanque de cimento amianto como alternativa para medir evaporação. 2000. 114f. (Dissertação de Mestrado em Meteorologia), Curso de Mestrado em Meteorologia, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba - Campus II - Campina Grande – Paraíba – Brasil, 2000. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2096 pt_BR