DSpace/Manakin Repository

Análise das instalações elétricas de uma casa de farinha em Santana de Piauí e adequação à NBR 5410:2004.

Mostrar registro simples

dc.creator.ID ROCHA, J. M. L. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/6165974292610941 pt_BR
dc.contributor.advisor1 VILAR, Pablo Bezerra.
dc.contributor.advisor1ID VILAR, P. B. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0812402232984399 pt_BR
dc.contributor.referee1 SOUZA, Ronimack Trajano de.
dc.description.resumo As instalações elétricas nada mais são do que a infraestrutura responsável por permitir que os equipamentos elétricos recebam energia elétrica das concessionárias ou de outras fontes de energia. Para que os equipamentos elétricos funcionem adequadamente é necessário que as instalações elétricas estejam dimensionadas corretamente, do contrário, o funcionamento desses equipamentos estará comprometido e não só isso, toda a instalação elétrica em si poderá representar um risco à vida das pessoas. Para que as instalações elétricas de baixa tensão sejam dimensionadas (e possam ser executadas) adequadamente a Norma Brasileira Regulamentadora 5410 de 2004 (NBR 5410:2004) estabelece os requisitos que estas instalações devem atender. Entretanto, a maioria das instalações elétricas de baixa tensão do Brasil não obedece ao que estabelece a NBR 5410:2004. Nesse sentido, o presente trabalho analisou o estado das instalações elétricas de uma casa de farinha em Santana do Piauí/PI, verificando os principais pontos de não conformidades com a NBR 5410:2004. Além disso, foi elaborado um projeto elétrico como proposta de adequação para as não conformidades encontradas e o orçamento dos materiais necessários à adequação. A análise das instalações elétricas em estudo foi feita a partir de um levantamento de informações “in loco”. Verificou-se que a instalação elétrica apresenta diversos pontos de não conformidades com a NBR 5410:2004, tais como: ausência de medidas de proteção contra choques elétricos, ausência de dispositivos de proteção contra surtos elétricos, incorreta divisão dos circuitos terminais, etc. Os resultados obtidos evidenciam que a instalação elétrica em questão necessita de inúmeras correções. Evidenciam também que os projetos elaborados seguindo os requisitos estabelecidos pelas normas, evitam inúmeros transtornos aos donos das edificações. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Análise das instalações elétricas de uma casa de farinha em Santana de Piauí e adequação à NBR 5410:2004. pt_BR
dc.date.issued 2021
dc.description.abstract Electrical installations are nothing more than the infrastructure responsible for allowing electrical equipment to receive electrical energy from utilities or other sources of energy so that they can perform the functions for which they were designed. For the electrical equipment to function properly, it is necessary that the electrical installations are correctly sized, otherwise, the operation of this equipment will be compromised and not only that, the entire electrical installation itself may represent a risk to people's lives. In order for low voltage electrical installations to be dimensioned and properly executed, the Brazilian Regulatory Standard 5410 of 2004 (NBR 5410: 2004) establishes the requirements that these installations must meet. However, the majority of low voltage electrical installations in Brazil do not comply with NBR 5410: 2004. In this sense, the present work analyzed the state of the electrical installations of a flour mill in Santana do Piauí/PI, verifying the main points of non-conformities with NBR 5410: 2004. In addition, an electrical project was prepared as a proposal to adapt to the nonconformities found and their respective budget. The analysis of the electrical installations under study was made based on a survey of information “in loco”. It was found that the electrical installation presents several points of non-conformities such as NBR 5410: 2004, such as: the correct dimensioning of the protection devices, the division of the circuits and the section of the conductors. The results obtained show that the electrical installation in question needs numerous corrections. They also show that the project prepared by a qualified professional avoids numerous inconveniences to the building owners. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/21023
dc.date.accessioned 2021-09-08T18:00:11Z
dc.date.available 2021-09-08
dc.date.available 2021-09-08T18:00:11Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject NBR 5410:2004 pt_BR
dc.subject Instalações elétricas pt_BR
dc.subject Casa de farinha pt_BR
dc.subject Análise das não conformidades pt_BR
dc.subject Electrical installations pt_BR
dc.subject Flour house pt_BR
dc.subject Analysis of non-compliances pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator ROCHA, João Marcos Leal.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Analysis of the electrical installations of a flour house in Santana de Piauí and adaptation to NBR 5410:2004. pt_BR
dc.identifier.citation ROCHA, João Marcos Leal. Análise das instalações elétricas de uma casa de farinha em Santana de Piauí e adequação à NBR 5410:2004. 2021. 57f. (Trabalho de Conclusão de Curso - Monografia), Curso de Bacharelado em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba - Brasil, 2021. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/21023 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta