dc.creator.ID BEZERRA, S. P. pt_BR
dc.contributor.advisor1 LUCENA, Francisco Barbosa de.
dc.contributor.advisor1ID LUCENA, F. B. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2428621932018732 pt_BR
dc.contributor.advisor2 BAUER, Gunter E.
dc.contributor.advisor2ID BAUER, G. E. pt_BR
dc.contributor.referee1 FERREIRA, Heber Carlos.
dc.contributor.referee2 TOLEDO FILHO, Romildo Dias.
dc.description.resumo Este trabalho apresenta um estudo comparativo da aplicação do SPT, da prova de carga sobre placas e do ensaio pressiométrico em projetos de fundações superficiais em solos arenosos, com o objetivo de mostrar a possibilidade do uso alternativo do pressiômetro de Briaud, em substituição à prova de carga e ao SPT, e suas vantagens. O campo experimental é um subsolo areno-siltoso situado na zona urbana de Campina Grande-PB, no qual executa-se sondagensSPT, provas de carga sobre placas apoiadas na superfície, provas de carga, em profundidade - com carregamentos verticais e horizontais - e ensaios pressiométricos em furos verticais e horizontais, além da verificação da densidade in situ e do teor de umidade natural, todos em um perfil com 1,90 m de profundidade. Comenta-se as vantagens e desvantagens dos ensaios realizados e verifica-se que a técnica pressiométrica - via pressiômetro de Briaud - apresenta muitas vantagens sobre a prova de carga e, ainda, que o SPT não deve, isoladamente, ser aplicado para estimar a capacidade de carga de fundações superficiais. Finalmente, conclui-se que os resultados obtidos evidenciam a possibilidade de aplicação do pressiômetro de Briaud, na determinação da capacidade de carga de fundações superficiais, em solos arenosos. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil. pt_BR
dc.subject.cnpq Geotecnia. pt_BR
dc.title Estudo comparativo entro o SPT, a prova de carga sobre placas e o ensaio pressiométrico, aplicado a fundações superficiais em solo arenoso - resultados preliminares. pt_BR
dc.date.issued 1990-04
dc.description.abstract This paper presents a comparative study of the application of the 5PT, of the plate load test, and of the pressuremeter test on shallow foundations projects in sandy soils, aiming at showing the possibility of alternative usage of the BRIAUD pressuremeter test as a substitute to both the plate load test and the 5PT, and their advantages. The experimental field is a silty-sand subsoil situated on the urban área of Campina Grande, Paraíba, where we carry out SPT soundings , plate load tests supported on the surface, plate load tests in depth - with vertical and horizontal loads - and pressuremeter tests in vertical and horizontal holes, besides the verification of the natural unit weight and the natural water content, ali of them in a profile of 1.90 meters deep. Following, we discuss the advantages and disadvantages of the experiments done and we get to know that the pressuremeter technique - throug the BRIAUD pressuremeter - offer many advantages concerning plate load tests; and, in addition, that the 5PT should not, in isolation, be applied to estimate the ultimate bearing capacity of shallow foundations. At the end, we conclude that the results reached give us proof of reasons to believe of the possibility of application of the BRIAUD pressuremeter in determining the bearing capacity of shallow foundations in sandy soils. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2164
dc.date.accessioned 2018-11-10T13:23:14Z
dc.date.available 2018-11-10
dc.date.available 2018-11-10T13:23:14Z
dc.type Dissertação pt_BR
dc.subject Carga sobre placas pt_BR
dc.subject Ensaio pressiométrico pt_BR
dc.subject Fundações superficiais pt_BR
dc.subject Solo arenoso - fundações pt_BR
dc.subject Pressiômetro Briaud pt_BR
dc.subject Surface foundations pt_BR
dc.subject Sand ground - foundations pt_BR
dc.subject Load on plates pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator BEZERRA, Sosthemar Pedrosa.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Comparative study between the SPT, the load test on plates and the pressiometric test, applied to surface foundations in sandy soil - preliminary results. pt_BR
dc.description.sponsorship CNPq pt_BR
dc.description.sponsorship Capes pt_BR
dc.identifier.citation BEZERRA, Sosthemar Pedrosa Bezerra. Estudo comparativo entro o SPT, a prova de carga sobre placas e o ensaio pressiométrico, aplicado a fundações superficiais em solo arenoso - resultados preliminares. 1990. 240f. (Dissertação de Mestrado em Engenharia Civil), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 1990. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2164 pt_BR