DSpace/Manakin Repository

Estratégia de controle e proteção das turbinas eólicas com geradores duplamente alimentados para suportabilidade a afundamentos de tensão.

Mostrar registro simples

dc.creator.ID SILVA, S. O. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/5496447230188739 pt_BR
dc.contributor.advisor1 NEVES, Washington Luiz Araújo.
dc.contributor.advisor1ID NEVES, W. L. A. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3107104665517286 pt_BR
dc.contributor.advisor2 MOTA, Wellington Santos.
dc.contributor.advisor2ID MOTA, W. S.
dc.contributor.advisor2Lattes http://lattes.cnpq.br/5452666875321325
dc.description.resumo A contínua incorporação de geração distribuída às redes de energia elétrica no mundo, a partir de fontes renováveis, tem contribuído positivamente no fornecimento de energia. Dentre as fontes renováveis, a energia eólica tem-se destacado por ser promissora devido a sua viabilidade econômica e rápido desenvolvimento tecnológico. Entretanto, o setor de energia eólica baseado em geradores de indução de dupla alimentação, tem sido seriamente desafiado pelas novas exigências dos códigos de rede. Para cumprir os requisitos cada vez mais rigorosos sem reduzir a vantagem econômica dos sistemas eólicos, novas estratégias de controle e proteção para afundamentos estão sendo estudados. Para o sistema eólico, o crowbar com resistência constante é uma abordagem popular que protege os aerogeradores e melhora o percurso de baixa tensão. No entanto, as respostas do sistema dependem do grau de queda de tensão, uma vez que a resistência constante do crowbar pode estar sub ou sobre-estimada, resultando em danos a máquina. Portanto, a resistência do crowbar é um parâmetro importante e deve ser selecionado levando em consideração os limites de sobrecorrentes do rotor e sobretensão do barramento. Assim, nesta Tese apresenta-se uma estratégia de controle que permite regular as potências ativa e reativa do gerador de indução duplamente alimentado de forma estável e independente, e um sistema de proteção de controle adaptativo para seleção da resistência do crowbar decorrente do grau de afundamento. É apresentada uma expressão analítica para a resistência, juntamente com a estratégia de controle. A eficácia do método proposto é validada por meio de análise teórica e simulações no Matlab/Simulinkr. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM LETRAS EM REDE PROFLETRAS (UFRN) pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica. pt_BR
dc.title Estratégia de controle e proteção das turbinas eólicas com geradores duplamente alimentados para suportabilidade a afundamentos de tensão. pt_BR
dc.date.issued 2020-04
dc.description.abstract The continuous integration of distributed generation into the world’s electricity networks, from renewable sources, has contributed positively to the generation of energy. Among the renewable sources, wind energy has stood out for being promising due to its economic viability and rapid technological development. To satisfy the increasingly stringent requirements without reducing the economic advantage of wind power systems, new control and protection strategies for sags are being studied. For the wind system, crowbar with constant resistance is a popular approach that protects aerogenerators and improves the low voltage path. However, the system’s responses depend on the degree of voltage drop, as the constant crowbar resistance may be under or overestimated, resulting in damage to the machine. Therefore, the crowbar resistance is an important parameter and should be selected taking into consideration the limits of rotor overcurrent and bus overvoltage. Thus, this Thesis presents a control strategy that allows regulating the active and reactive powers of the induction generator doubly fed in a stable and independent way, and an adaptive control protection system for selecting the crowbar resistance due to the degree of sag. An analytical expression for the resistance is presented together with the control strategy. The effectiveness of the proposed method is validated through theoretical analysis and simulations in Matlab/Simulinkr. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/21880
dc.date.accessioned 2021-11-08T12:21:24Z
dc.date.available 2021-11-08
dc.date.available 2021-11-08T12:21:24Z
dc.type Tese pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Stefânia de Oliveira.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Control and protection strategy for wind turbines with double-fed generators for withstand voltage sags. pt_BR
dc.description.sponsorship Capes pt_BR
dc.identifier.citation SILVA, Stefânia de Oliveira. Estratégia de controle e proteção das turbinas eólicas com geradores duplamente alimentados para suportabilidade a afundamentos de tensão. 2020. 128f. (Tese de Doutorado) Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2020. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/21880 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta