Avaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020.

Mostrar registro simples

dc.creator.Lattes http://lattes.cnpq.br/2033392540252868 pt_BR
dc.contributor.advisor1 VILAR, Eudésio Oliveira.
dc.contributor.advisor1Lattes http://lattes.cnpq.br/6363257813968241 pt_BR
dc.contributor.referee1 ALVES, Jose Jailson Nicacio.
dc.contributor.referee1Lattes http://lattes.cnpq.br/7986759552135066 pt_BR
dc.contributor.referee2 SILVA, José Nilton.
dc.contributor.referee2Lattes http://lattes.cnpq.br/7853090239572747 pt_BR
dc.contributor.referee3 ARAÚJO, Bruno Allison
dc.contributor.referee3Lattes http://lattes.cnpq.br/0265579541739809 pt_BR
dc.contributor.referee4 LIMA, Juliana de Figueiredo
dc.contributor.referee4Lattes http://lattes.cnpq.br/6140386020886145 pt_BR
dc.description.resumo A fragilização por hidrogênio, de um metal ou liga, é um problema industrial que pode levar a danos estruturais, quando em condições ótimas acontecerá. Com base nesta premissa o presente estudo teve como objetivo estudar o efeito mitigador da permeação do hidrogênio, pela liga Zn-Ni eletrodepositada sobre Aço SAE 1020. Esta liga, com baixo teor de carbono, é um dos aços mais comumente utilizados na indústria de processo, com excelente relação custo benefício comparado com outros aços destinados ao mesmo propósito. Foram escolhidas duas metodologias para galvanizar este aço com a liga Zn- Ni; uma a base de cloretos e outra a base de sulfatos, com intuito de comparar seus efeitos à permeação de hidrogênio. Inicialmente, foi realizada uma caracterização da corrosão eletroquímica destes e sua análise morfológica, onde ficou constatado que estes revestimentos protegem o metal de base tanto à corrosão quanto a difusão de hidrogênio, porém o processo de eletrodeposição do Zn-Ni a base de sulfatos obteve uma maior concentração de níquel e melhor resistência a corrosão de acordo com os dados obtidos e permeação. Os revestimentos de Zn-Ni diminuíram a susceptibilidade do SAE 1020 à permeação por hidrogênio; onde o revestimento a base de sulfatos obteve razão de alongamento de 95%. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Química pt_BR
dc.title Avaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020. pt_BR
dc.date.issued 2021-09-23
dc.description.abstract The embrittlement by hydrogen, of a metal or an alloy, is an industrial problem that can lead to structural damage, when in optimal conditions it will happen. Based on this premise, the present study aimed to study the mitigating effect of hydrogen permeation, by the Zn-Ni alloy electrodeposited on SAE 1020 Steel. This alloy, with low carbon content, is one of the most commonly used steels in the process industry , with an excellent cost-benefit ratio compared to other steels intended for the same purpose. Two methodologies were chosen to galvanize this steel with the Zn-Ni alloy; one based on chlorides and the other based on sulfates, in order to compare their effects to hydrogen permeation. Initially, a characterization of the electrochemical corrosion of these and its morphological analysis was performed, where it was found that these coatings protect the base metal both to corrosion and hydrogen diffusion, but the Zn-Ni electrodeposition process based on sulfates obtained a higher nickel concentration and better corrosion resistance according to the obtained data and permeation. Zn-Ni coatings decreased the susceptibility of SAE 1020 to hydrogen permeation; where the coating based on sulfates obtained an elongation ratio of 95%. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/22655
dc.date.accessioned 2021-12-20T15:32:47Z
dc.date.available 2021-12-20
dc.date.available 2021-12-20T15:32:47Z
dc.type Tese pt_BR
dc.subject Fragilização por hidrogênio pt_BR
dc.subject Permeação por hidrogênio pt_BR
dc.subject Aço SAE 1020 pt_BR
dc.subject Eletrodeposição de Zn-Ni pt_BR
dc.subject Corrosão pt_BR
dc.subject Hydrogen embrittlement pt_BR
dc.subject hydrogen permeation pt_BR
dc.subject SAE 1020 steel pt_BR
dc.subject Zn-Ni electrodeposition pt_BR
dc.subject Corrosion pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator CARVALHO, João Paulo Dantas de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation of hydrogen permeation through the Zn-Ni alloy electrodeposited on SAE 1020 steel.
dc.description.sponsorship Capes pt_BR
dc.identifier.citation CARVALHO, João Paulo Dantas de. Avaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020. 121f. Tese (Doutorado em Engenharia Química) - Programa de Pós- Graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2021. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/22655 pt_BR