dc.creator.Lattes |
http://lattes.cnpq.br/2033392540252868 |
pt_BR |
dc.contributor.advisor1 |
VILAR, Eudésio Oliveira. |
|
dc.contributor.advisor1Lattes |
http://lattes.cnpq.br/6363257813968241 |
pt_BR |
dc.contributor.referee1 |
ALVES, Jose Jailson Nicacio. |
|
dc.contributor.referee1Lattes |
http://lattes.cnpq.br/7986759552135066 |
pt_BR |
dc.contributor.referee2 |
SILVA, José Nilton. |
|
dc.contributor.referee2Lattes |
http://lattes.cnpq.br/7853090239572747 |
pt_BR |
dc.contributor.referee3 |
ARAÚJO, Bruno Allison |
|
dc.contributor.referee3Lattes |
http://lattes.cnpq.br/0265579541739809 |
pt_BR |
dc.contributor.referee4 |
LIMA, Juliana de Figueiredo |
|
dc.contributor.referee4Lattes |
http://lattes.cnpq.br/6140386020886145 |
pt_BR |
dc.description.resumo |
A fragilização por hidrogênio, de um metal ou liga, é um problema industrial que pode
levar a danos estruturais, quando em condições ótimas acontecerá. Com base nesta
premissa o presente estudo teve como objetivo estudar o efeito mitigador da permeação
do hidrogênio, pela liga Zn-Ni eletrodepositada sobre Aço SAE 1020. Esta liga, com
baixo teor de carbono, é um dos aços mais comumente utilizados na indústria de processo,
com excelente relação custo benefício comparado com outros aços destinados ao mesmo
propósito. Foram escolhidas duas metodologias para galvanizar este aço com a liga Zn-
Ni; uma a base de cloretos e outra a base de sulfatos, com intuito de comparar seus efeitos
à permeação de hidrogênio. Inicialmente, foi realizada uma caracterização da corrosão
eletroquímica destes e sua análise morfológica, onde ficou constatado que estes
revestimentos protegem o metal de base tanto à corrosão quanto a difusão de hidrogênio,
porém o processo de eletrodeposição do Zn-Ni a base de sulfatos obteve uma maior
concentração de níquel e melhor resistência a corrosão de acordo com os dados obtidos e
permeação. Os revestimentos de Zn-Ni diminuíram a susceptibilidade do SAE 1020 à
permeação por hidrogênio; onde o revestimento a base de sulfatos obteve razão de
alongamento de 95%. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Ciências e Tecnologia - CCT |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Química |
pt_BR |
dc.title |
Avaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020. |
pt_BR |
dc.date.issued |
2021-09-23 |
|
dc.description.abstract |
The embrittlement by hydrogen, of a metal or an alloy, is an industrial problem that can
lead to structural damage, when in optimal conditions it will happen. Based on this
premise, the present study aimed to study the mitigating effect of hydrogen permeation,
by the Zn-Ni alloy electrodeposited on SAE 1020 Steel. This alloy, with low carbon
content, is one of the most commonly used steels in the process industry , with an
excellent cost-benefit ratio compared to other steels intended for the same purpose. Two
methodologies were chosen to galvanize this steel with the Zn-Ni alloy; one based on
chlorides and the other based on sulfates, in order to compare their effects to hydrogen
permeation. Initially, a characterization of the electrochemical corrosion of these and its
morphological analysis was performed, where it was found that these coatings protect the
base metal both to corrosion and hydrogen diffusion, but the Zn-Ni electrodeposition
process based on sulfates obtained a higher nickel concentration and better corrosion
resistance according to the obtained data and permeation. Zn-Ni coatings decreased the
susceptibility of SAE 1020 to hydrogen permeation; where the coating based on sulfates
obtained an elongation ratio of 95%. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/22655 |
|
dc.date.accessioned |
2021-12-20T15:32:47Z |
|
dc.date.available |
2021-12-20 |
|
dc.date.available |
2021-12-20T15:32:47Z |
|
dc.type |
Tese |
pt_BR |
dc.subject |
Fragilização por hidrogênio |
pt_BR |
dc.subject |
Permeação por hidrogênio |
pt_BR |
dc.subject |
Aço SAE 1020 |
pt_BR |
dc.subject |
Eletrodeposição de Zn-Ni |
pt_BR |
dc.subject |
Corrosão |
pt_BR |
dc.subject |
Hydrogen embrittlement |
pt_BR |
dc.subject |
hydrogen permeation |
pt_BR |
dc.subject |
SAE 1020 steel |
pt_BR |
dc.subject |
Zn-Ni electrodeposition |
pt_BR |
dc.subject |
Corrosion |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
CARVALHO, João Paulo Dantas de. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Evaluation of hydrogen permeation through the Zn-Ni alloy electrodeposited on SAE 1020 steel. |
|
dc.description.sponsorship |
Capes |
pt_BR |
dc.identifier.citation |
CARVALHO, João Paulo Dantas de. Avaliação da permeação do hidrogênio através da liga Zn-Ni eletrodepositada sobre o aço SAE 1020. 121f. Tese (Doutorado em Engenharia Química) - Programa de Pós-
Graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2021. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/22655 |
pt_BR |