DSpace/Manakin Repository

Aplicação de sistema de lodo ativado em bateladas sequenciais para a remoção biológica de nitrogênio do esgoto de um condomínio residencial.

Mostrar registro simples

dc.creator.ID MENEZES, G. A. pt_BR
dc.contributor.advisor1 HAANDEL, Adrianus Cornelius Van.
dc.contributor.advisor1ID HAANDEL, A. C. V. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4982723988716062 pt_BR
dc.contributor.referee1 COURA, Mônica de Amorim.
dc.contributor.referee2 SANTOS, Silvânia Lucas dos.
dc.description.resumo Com o crescimento da população e o desenvolvimento industrial dos últimos séculos, o volume de afluente produzido nos grandes e pequenos centros experimentou um crescimento exponencial, a humanidade tem então a sua atenção voltada para o destino final e prejuízos ambientais que este volume crescente causa, a curto e longo prazo. É partindo deste raciocínio que surge como alternativa mais viável o tratamento deste resíduo de esgoto e, como alternativa eficaz e a baixo custo, o tratamento biológico. Este trabalho apresenta a discussão da montagem e operação de um sistema de lodo ativado em regime de bateladas sequenciais, tendo em vista a obtenção de parâmetros satisfatórios para a remoção da matéria orgânica e nitrogênio oriundos de águas residuárias municipais, mais especificamente de um condomínio residencial em Campina Grande. Neste estudo foram calculadas e checadas as condições operacionais para um sistema operando nitrificação e desnitrificação em câmaras separadas por meio de dois reatores com capacidade de 500L que estavam interligados e, portanto compartilhavam de uma vazão de recirculação, fator este que se mostrou fundamental para atingirse o equilíbrio do sistema nas duas zonas e, com o auxílio de testes laboratoriais e da teoria, esta deverá se encontrar na faixa entre 250 e 280 L/h. Concluise que para o equilíbrio do sistema, o monitoramento laboratorial da razão entre nitrificação e desnitrificação, suas taxas e volumes presentes em cada reator, bem como da correta automatização das fases do sistema realizada por temporizadoresé assunto de fundamental importância. Por fim, verificase que o sistema operando para a montagem realizada apresenta potencial de tratamento favorável para remoção de nitrogênio e matéria orgânica desde que monitorado periodicamente e apresente condições para estabilização da biomassa. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil pt_BR
dc.title Aplicação de sistema de lodo ativado em bateladas sequenciais para a remoção biológica de nitrogênio do esgoto de um condomínio residencial. pt_BR
dc.date.issued 2018
dc.description.abstract With population growth and industrial development over the last few centuries, the volume of wastewater produced in large and small centers has grown exponentially, humanity is now focusing on the final destination and environmental damage that this increasing volume causes, in a short and a long term. On this reasoning,the treatment of wastewater appears as a more viable alternative and, as an effective alternative and at low cost, the biological treatment. This work presents the discussion of the assembly and operation of a sludge activated system in a sequential batch regime, in order to obtain satisfactory parameters for the removal of organic matter and nitrogen from municipal wastewater, more specifically from a residential condominium in Campina Grande. In this study, the operating conditions were calculated and checked for a system operating nitrification and denitrification in separate chambers by means of two reactors with capacity of 500L that were interconnected and, therefore, shared a recirculation flow, the balance of the system in the two zones and, with the aid of laboratory tests and theory, should be in the range between 250 and 280 L / h. It is concluded that for the equilibrium of the system the laboratorial monitoring of the ratio between nitrification and denitrification, its rates and volumes present in each reactor, as well as the correct automation of the phases of the system performed by timersis matter of fundamental importance. Finally, it is verified that the system operating for the assembly carried out presents favorable treatment potential for the removal of nitrogen and organic matter since it is monitored periodically and presents conditions for stabilization of the biomass. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23491
dc.date.accessioned 2022-02-11T19:15:20Z
dc.date.available 2022-02-11
dc.date.available 2022-02-11T19:15:20Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Esgoto pt_BR
dc.subject Sistema de lodo ativado pt_BR
dc.subject Bateladas sequenciais pt_BR
dc.subject Matéria orgânica pt_BR
dc.subject Desnitrificação pt_BR
dc.subject Nitrificação pt_BR
dc.subject Lodo ativado pt_BR
dc.subject Matéria orgânica pt_BR
dc.subject Águas residuárias pt_BR
dc.subject Saneamento básico pt_BR
dc.subject Reator de bateladas sequenciais pt_BR
dc.subject Sistema aeróbio - lodo ativado pt_BR
dc.subject Sistema aeróbio - lodo ativado pt_BR
dc.subject Cinética de nitrificação pt_BR
dc.subject Tratamento de esgoto residencial pt_BR
dc.subject Sewer pt_BR
dc.subject Activated sludge system pt_BR
dc.subject Sequential batches pt_BR
dc.subject Organic matter pt_BR
dc.subject Denitrification pt_BR
dc.subject Nitrification pt_BR
dc.subject Activated sludge pt_BR
dc.subject Organic matter pt_BR
dc.subject Wastewater pt_BR
dc.subject Basic sanitation pt_BR
dc.subject Sequential batch reactor pt_BR
dc.subject Aerobic system - activated sludge pt_BR
dc.subject Nitrification kinetics pt_BR
dc.subject Residential sewage treatment pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator MENEZES, Gabriel Alves de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Application of an activated sludge system in sequential batches for the biological removal of nitrogen from the sewage of a residential condominium. pt_BR
dc.identifier.citation MENEZES, Gabriel Alves de Menezes. Aplicação de sistema de lodo ativado em bateladas sequenciais para a remoção biológica de nitrogênio do esgoto de um condomínio residencial. 2018. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Engenharia Civil, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23491 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta