Dosagem de solo-cimento para reforço de base de fundações superficiais.

Mostrar registro simples

dc.creator.ID SILVA, J. C. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0710458134295111 pt_BR
dc.contributor.advisor1 SILVANI, Carina.
dc.contributor.advisor1ID SILVANI, C. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4898628325076026 pt_BR
dc.contributor.referee1 LOPES, Adriano Elísio de Figueiredo.
dc.contributor.referee1ID LOPES, A. E. F. pt_BR
dc.contributor.referee2 SOUZA JÚNIOR, Alexandre de.
dc.contributor.referee2ID SOUZA JÚNIOR, A. pt_BR
dc.description.resumo A estabilização com solo-cimento é uma das possibilidades para construção de edificações em regiões de solo com baixa capacidade de suporte. A mistura do solo local com cimento, devidamente dosada e compactada, adquiri resistência e apresenta durabilidade compatível com os critérios necessários para as construções. Neste trabalho, foi estudada a estabilização química de uma areia argilosa com o uso de cimento Portland de alta resistência inicial (CP V- ARI) aplicado como reforço de base de fundações superficiais do tipo sapata isolada através da metodologia de dosagem n/Civ. O estudo realizou o dimensionamento das fundações superficiais a partir do perfil geotécnico do solo, assim como ao cálculo da capacidade de carga do solo melhorado, por meio de métodos de cálculos obtidos na literatura e das curvas de dosagem n/Civ traçadas a partir dos resultados do ensaio de resistência a compressão simples realizados para o solo com 4%, 6% e 8% de cimento e peso específico de 14, 15 e 16kN/m³, e por fim, na definição do orçamento das sapatas assentadas em solo natural e melhorado. As sapatas foram dimensionadas para suportar uma carga de 187,3 toneladas centrada em um pilar de dimensão 80 x 35 cm, oriundos de dados da construção da escola técnica de Campina Grande-PB, onde foi adotado esse tipo de solução. Ambas as sapatas foram dimensionadas para assentamento a 2,00 m de profundidade. A sapata em solo natural exige dimensões de 190x80 cm para conseguir suportar a carga do pilar, enquanto a sapata em solo cimento necessita de dimensões abaixo do recomendado pela ABNT NBR 6122:2010, sendo adotado para este caso uma sapata de 140x60 cm, gerando uma redução de custos de 44%. Este resultado deve-se as menores dimensões necessárias para a sapata assentada em solo-cimento e consequente redução dos quantitativos de materiais. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil pt_BR
dc.title Dosagem de solo-cimento para reforço de base de fundações superficiais. pt_BR
dc.date.issued 2019
dc.description.abstract Stabilization with soil-cement is one of the possibilities for construction of buildings in regions of soil with low support capacity. The mixture of the local soil with cement, properly dosed and compacted, acquired resistance and presents durability compatible with the necessary criteria for the constructions. In this work, the chemical stabilization of a clayey sand with the use of Portland cement of high initial resistance (CP V - ARI) was studied as a base reinforcement of shallow foundations isolated by the methodology of /Civ. The study focused on the design of the shallow foundations from the geotechnical profile of the soil, as well as on the calculation of the natural and improved soil loading capacity, through calculation methods obtained in the literature and the /Civ dosage curves from the results of the unconfined compression test for soil with 4%, 6% and 8% of cement and dry density of 14, 15 and 16 kN / m³, and finally, in the definition of the budget of the shallow foundation seated in natural soil and improved soil. The shallow foundation was designed to withstand a load of 187.3 tons centered on a pillar of dimension 80 x 35 cm, coming from data of the construction of the technical school of Campina Grande-PB, where this type of solution was adopted. Both shallow foundations were dimensioned for settlement at 2.00 m depth. The shallow foundation over natural soil requires dimensions of 190x80 cm to be able to support the load of the abutment, while the shallow foundation over cemented soil needs dimensions below recommended by ABNT NBR 6122: 2010, being adopted for this case a shallow foundation of 140x60 cm, generating a cost reduction of 44%. This result is due to the smaller dimensions required for the shallow foundation seated in soil-cement and consequent reduction of the quantitative of materials pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23580
dc.date.accessioned 2022-02-16T11:08:08Z
dc.date.available 2022-02-16
dc.date.available 2022-02-16T11:08:08Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Fundações superficiais pt_BR
dc.subject Estabilização de solos pt_BR
dc.subject Solo-cimento - estabilização pt_BR
dc.subject Geotecnia pt_BR
dc.subject Sapata isolada pt_BR
dc.subject Orçamento de sapata isolada pt_BR
dc.subject Estabilização química de solos pt_BR
dc.subject Melhoramento do solo com cimento pt_BR
dc.subject Capacidade de cargas de fundações superficiais pt_BR
dc.subject Dimensionamento de fundações pt_BR
dc.subject Sondagem simples de reconhecimento pt_BR
dc.subject Teoria da capacidade de carga de Terzaghi pt_BR
dc.subject Cimento Portland pt_BR
dc.subject Cálculo da capacidade de carga do solo pt_BR
dc.subject Moldagem dos corpos de prova pt_BR
dc.subject Surface foundations pt_BR
dc.subject Soil stabilization pt_BR
dc.subject Soil-cement - stabilization pt_BR
dc.subject Geotechnics pt_BR
dc.subject Isolated shoe pt_BR
dc.subject Insulated shoe budget pt_BR
dc.subject Chemical soil stabilization pt_BR
dc.subject Soil improvement with cement pt_BR
dc.subject Surface foundation load capacity pt_BR
dc.subject Sizing of foundations pt_BR
dc.subject Simple recognition poll pt_BR
dc.subject Terzaghi's Carrying Capacity Theory pt_BR
dc.subject Portland cement pt_BR
dc.subject Calculation of soil carrying capacity pt_BR
dc.subject Molding of specimens pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Jucimara Cardoso da.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Soil-cement dosage for strengthening the base of shallow foundations. pt_BR
dc.identifier.citation SILVA, Jucimara Cardoso da. Dosagem de solo-cimento para reforço de base de fundações superficiais. 2019. 79f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Engenharia Civil, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2019. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23580 pt_BR