DSpace/Manakin Repository

Análise da carga orgânica em uma área alagada existente no Campus Sede da Universidade Federal de Campina Grande.

Mostrar registro simples

dc.creator.ID ARAÚJO, M. A. F. pt_BR
dc.contributor.advisor1 FEITOSA, Patrícia Hermínio Cunha.
dc.contributor.advisor1ID FEITOSA, P. H. C. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/8276706034302451 pt_BR
dc.contributor.advisor-co1 PEREIRA, Patrícia Alves.
dc.contributor.advisor-co1ID PEREIRA, P. A. pt_BR
dc.contributor.referee1 BARBOSA, Dayse Luna.
dc.contributor.referee1ID BARBOSA, D. L. pt_BR
dc.contributor.referee2 ROCHA, Elis Gean.
dc.contributor.referee2ID ROCHA, E. G. pt_BR
dc.description.resumo Foi realizada uma investigação ambiental em uma área alagada existente no Campus Sede da Universidade Federal de Campina Grande – UFCG, que recebe efluentes líquidos industriais e domésticos. Através do reconhecimento da área ao redor, do levantamento das atividades realizadas no entorno como potenciais fontes poluidoras e caracterizações físico-químicas das águas residuárias foi possível quantificar a carga orgânica existente nessa área. Em consequência disso, pôde-se relacionar ao tipo de efluente e sua origem em quatro pontos analisados. O objetivo deste trabalho foi avaliar a carga orgânica, a partir da análise de concentração de matéria orgânica na água. As análises de parâmetros pH, oxigênio dissolvido (OD), demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO), temperatura e pH, foram realizadas no Laboratório de Saneamento da própria universidade. Os poluentes lançados apresentam efeito negativo na qualidade da água da área em estudo, principalmente, quanto ao oxigênio dissolvido, onde devido a elevadas cargas orgânicas, podem ter consumido o oxigênio disponível, dificultando o processo de autodepuração da área. Os pontos analisados sofrem interferência de efluentes vindos de fora e de efluentes produzidos pelas atividades realizadas dentro da própria universidade. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil pt_BR
dc.title Análise da carga orgânica em uma área alagada existente no Campus Sede da Universidade Federal de Campina Grande. pt_BR
dc.date.issued 2018-03
dc.description.abstract The aim of this study was to evaluate the organic load in a flooded area at the Federal University of Campina Grande – UFCG, through the analysis of organic matter concentration in water. An environmental investigation was conducted in the flooded area which receives industrial and domestic liquid effluents. Through the recognition of the surrounded area, the survey of activities carried out in the environment as potentials source of pollution and physicochemical characterisation of wastewater, it was possible to quantify the organic load in the flooded area. Consequently, it was possible to relate the effluent type and its origin in four analysed points. Analysis of parameters such as pH, dissolved oxygen (DO), biochemical oxygen demand (BOD5), chemical oxygen demand (COD) and temperature were carried out in the Sanitation Laboratory of Federal University of Campina Grande. The released pollutants had a negative effect on the water quality of the flooded area, mainly in reason of to the dissolved oxygen, where due to high organic loads it may have consumed the available oxygen, hampering the process of self-purification of the area. The analysed points suffer interference from outside effluents and effluents produced by the activities conducted at the University. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23675
dc.date.accessioned 2022-02-22T19:11:35Z
dc.date.available 2022-02-22
dc.date.available 2022-02-22T19:11:35Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Universidade Federal de Campina Grande - Campus Sede - alagamentos pt_BR
dc.subject Alagamentos na UFCG pt_BR
dc.subject Área alagada - UFCG pt_BR
dc.subject Carga orgânica - área alagada - UFCG pt_BR
dc.subject Saneamento pt_BR
dc.subject Matéria orgânica - área alagada - UFCG pt_BR
dc.subject Autodepuração dos corpos d'água pt_BR
dc.subject Qualidade da água pt_BR
dc.subject Parâmetros físico-químicos da água - UFCG pt_BR
dc.subject Esgoto industrial pt_BR
dc.subject Efluentes líquidos industriais - UFCG pt_BR
dc.subject Poluição da água - áreas urbanas pt_BR
dc.subject Áreas úmidas em centros urbanos pt_BR
dc.subject Federal University of Campina Grande - Headquarters Campus - flooding pt_BR
dc.subject Flooding at UFCG pt_BR
dc.subject Flooded area - UFCG pt_BR
dc.subject Organic load - flooded area - UFCG pt_BR
dc.subject Sanitation pt_BR
dc.subject Organic matter - flooded area - UFCG pt_BR
dc.subject Self-purification of water bodies pt_BR
dc.subject Water quality pt_BR
dc.subject Physicochemical parameters of water - UFCG pt_BR
dc.subject Industrial sewage pt_BR
dc.subject Industrial liquid effluents - UFCG pt_BR
dc.subject Water pollution - urban areas pt_BR
dc.subject Wetlands in urban centers pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator ARAÚJO, Moama Arruda Felinto de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Analysis of the organic load in an existing flooded area on the Campus Sede of the Federal University of Campina Grande. pt_BR
dc.identifier.citation ARAÚJO, Moama Arruda Felinto de. Análise da carga orgânica em uma área alagada existente no Campus Sede da Universidade Federal de Campina Grande. 2018. 47f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Engenharia Civil, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23675 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta