DSpace/Manakin Repository

Ajuste da curva de retenção de água do solo da camada de cobertura de uma célula experimental de resíduos sólidos urbanos.

Mostrar registro simples

dc.creator.Lattes http://lattes.cnpq.br/2914466087121393 pt_BR
dc.contributor.advisor1 MONTEIRO, Veruschka Escarião Dessoles.
dc.contributor.advisor1Lattes http://lattes.cnpq.br/6102407715279049 pt_BR
dc.contributor.referee1 LUCENA, Adriano Elísio de Figueiredo Lopes.
dc.contributor.referee1Lattes http://lattes.cnpq.br/4428634327768673 pt_BR
dc.contributor.referee2 ARAÚJO, Pabllo da Silva.
dc.contributor.referee2Lattes http://lattes.cnpq.br/9909741140351243 pt_BR
dc.description.resumo Os aterros sanitários necessitam de monitoramento constante de sua camada de cobertura visando melhorar sua capacidade de isolar os Resíduos Sólidos Urbanos (RSU) e evitar a exposição desses resíduos no meio ambiente. Os aterros sanitários, geralmente, possuem uma camada de cobertura impermeabilizante que restringe o contato desses resíduos com o meio externo, além de impedir que os gases gerados dentro da Célula entrem em contato com o ambiente e que a água da chuva percole para o interior Célula. A determinação do solo mais adequado para compor a camada de cobertura é de suma importância para o estudo dos aterros sanitários, tendo em vista a necessidade de isolar os resíduos que compõe o aterro. O presente trabalho consiste na análise da camada de cobertura de uma célula experimental, que simula uma célula de aterro sanitário, localizada na Universidade Federal de Campina Grande, Paraíba, objetivando avaliar a relação sucção/umidade do solo e comparála com a da camada de cobertura do aterro em escala real. Amostras indeformadas foram retiradas da camada de cobertura de solo compactado da célula experimental e levadas ao laboratório de Geotecnia Ambiental onde foi realizada a medição da sucção pelo método do papel filtro, possibilitando a obtenção dos dados necessários para construção da curva de retenção de água do solo. Utilizando o Software STATISTICA for Windows 8.0 foi possível ajustar a curva, obter os parâmetros necessários, sendo eles o Coeficiente de Determinação (R²), Soma dos Quadrados dos Resíduos (SQR) e o Critério de Informação AKAIKE (AIC), e assim determinar o modelo que melhor se adequa ao solo estudado. Os resultados encontrados mostraram que a curva de retenção de água do solo da camada de cobertura da célula experimental apresentava baixa retenção de água, caracterizando um solo arenoso, ao contrário da caracterização realizada anteriormente, que encontrou uma classificação para um solo argiloso, demonstrando que o solo estudado sofreu alterações com o tempo devido a intemperismos, lixiviação, variações de temperatura, possibilitando inconformidade com a relação sucção/umidade de um solo argiloso. A partir da curva ajustada, verificouse que a equação de Van Genuchten melhor representava o solo estudado devido aos parâmetros estatístico encontrados. Também foi possível determinar, a partir da análise da curva de retenção de água do solo, que o solo da camada de cobertura do aterro sanitário se mostrou mais eficaz para a finalidade de camada de cobertura, tendo em vista sua maior capacidade de retenção de água em comparação com o solo da camada de cobertura da célula experimental. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil pt_BR
dc.title Ajuste da curva de retenção de água do solo da camada de cobertura de uma célula experimental de resíduos sólidos urbanos. pt_BR
dc.date.issued 2017-09
dc.description.abstract Landfills require constant monitoring of their cover layer in order to improve their ability to isolate Urban Solid Waste (MSW) and to avoid exposure of these wastes to the environment. Sanitary landfills generally have a layer of waterproofing cover that restricts the contact of these residues with the external environment, in addition to preventing gases generated inside the cell from coming into contact with the environment and that the rainwater falls to the inside Cell. The determination of the most suitable soil to compose the cover layer is of paramount importance for the study of the sanitary landfills, considering the need to isolate the wastes that make up the landfill. The present work consists in the analysis of the cover layer of an experimental cell, which simulates a landfill cell, located at the Federal University of Campina Grande, Paraíba, to evaluate the suction / moisture ratio of the soil and to compare it with the layer landfill coverage. Undeformed samples were taken from the compacted soil cover layer of the experimental cell and taken to the Environmental Geotechnics laboratory where the suction measurement was carried out by the filter paper method, enabling the data required to construct the soil water retention curve. Using the STATISTICA for Windows 8.0 software, it was possible to adjust the curve to obtain the necessary parameters, such as the Determination Coefficient (R²), Sum of Squares of Residuals (SQR) and the AKAIKE Information Criterion (AIC). model that best suits the studied soil. The results showed that the soil water retention curve of the cover layer of the experimental cell presented low retention of water, characterizing a sandy soil, unlike the previous characterization, that found a classification for a clay soil, demonstrating that the soil studied underwent alterations with time due to weathering, leaching, temperature variations, allowing nonconformity with the suction / moisture ratio of a clay soil. From the adjusted curve, it was verified that the Van Genuchten equation better represented the studied soil due to the statistical parameters found. It was also possible to determine, from the soil water retention curve analysis, that the soil of the landfill cover layer was more effective for the cover layer purpose, considering its greater water retention capacity in comparison with the soil of the cover layer of the experimental cell. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23938
dc.date.accessioned 2022-03-21T12:02:39Z
dc.date.available 2022-03-21
dc.date.available 2022-03-21T12:02:39Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Resíduos sólidos urbanos pt_BR
dc.subject Célula experimental - resíduos sólidos urbanos pt_BR
dc.subject Curva de retenção de água pt_BR
dc.subject Sucção matricial pt_BR
dc.subject Aterros sanitários pt_BR
dc.subject Solos não saturados pt_BR
dc.subject Solo de aterro sanitário pt_BR
dc.subject Método do papel filtro pt_BR
dc.subject Urban solid waste pt_BR
dc.subject Experimental cell - municipal solid waste pt_BR
dc.subject Water retention curve pt_BR
dc.subject Matrix suction pt_BR
dc.subject Sanitary landfills pt_BR
dc.subject Unsaturated soils pt_BR
dc.subject Landfill soil pt_BR
dc.subject Filter paper method pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator TAVARES, Pedro Vítor Cartaxo.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Fitting the soil water retention curve of the cover layer of an experimental urban solid waste cell. pt_BR
dc.identifier.citation TAVARES, Pedro Vítor Cartaxo. Ajuste da curva de retenção de água do solo da camada de cobertura de uma célula experimental de resíduos sólidos urbanos. 2017. 44f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Engenharia Civil, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/23938 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta