DSpace/Manakin Repository

Determinação dos parâmetros fisiológicos e utilização da câmera termográfica para diagnosticar lesões em equinos de salto na cidade de João Pessoa - PB.

Mostrar registro simples

dc.creator.ID MENDONÇA, M. F. F. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0972447649131333 pt_BR
dc.contributor.advisor1 MIRANDA NETO, Eldinê Gomes de.
dc.contributor.advisor1ID MIRANDA NETO, E. G. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2248342061308865 pt_BR
dc.contributor.advisor2 ROBERTO, José Vinícius Barbosa.
dc.contributor.advisor2ID ROBERTO, J. V. B. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/0804265970839014 pt_BR
dc.contributor.referee1 MEDEIROS, Gildenor Xavier.
dc.contributor.referee1ID MEDEIROS, G. X. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/3745442405782063 pt_BR
dc.contributor.referee2 ASSIS, Daniel de Medeiros.
dc.contributor.referee2ID ASSIS, D. M. pt_BR
dc.contributor.referee2Lattes http://lattes.cnpq.br/0843544055382775 pt_BR
dc.description.resumo O presente trabalho teve com objetivo determinar os parâmetros fisiológicos de cavalos utilizados em provas de hipismo clássico no município de João Pessoa, no estado da Paraíba- PB, como também empregar a termografia de infravermelho para diagnosticar possíveis lesões causadas pelo treinamento físico, promovendo assim, um protocolo de treinamento mais adequado a esses animais de forma a atender exigências do esporte. Para isto, foram determinados os seguintes parâmetros: frequência cardíaca (FC), frequência respiratória (FR), temperatura retal (TR) e em seguida realizaram-se nove projeções de cada animal com o auxilio da câmera termográfica, obtendo-se a temperatura superficial (TS). Essas variáveis foram mensuradas antes do treino (AT), após o treino (PT) e duas horas após o treino (2h PT). Foram utilizados 10 equinos atletas, das raças Brasileiro de Hipismo (BH), Sela Francesa, Westphalen Alemão, Sela Argentina, e Sem Raça Definida (SRD), sendo oito machos e duas fêmeas, com idades variando de 5 a 14 anos, alojados na hípica Thuany. Todos os animais encontravam-se saltando provas do circuito paraibano de hipismo com alturas de obstáculo que variam de acordo com cada categoria, compreendendo a marca de 1m a 1,30m, os quais foram divididos em dois grupos, G1 e G2. O estudo foi realizado no período de outubro de 2013 a maio de 2014 com total de cinco coletas. Os valores médios encontrados da variável FC para G1 foram: AT 33bpm; PT 62bpm; e 2h PT 34bpm. Para G2 foram: AT 31bpm; PT 65bpm; e 2h PT 35bpm. Os resultados médios para FR do G1 foram: AT 23mpm; PT 57mpm; e 27mpm. Para o G2 foram: AT 24mpm; PT 71mpm; e 2h PT 26mpm. A média da variável TR do G1 foi: AT 37,4ºC; PT 38,9ºC; e 2h PT 37,7ºC, já para G2 foi: AT 37,4ºC; PT 39,1ºC; e 2h PT 37,7ºC. A variável TS foi dividida em: Avaliações dos membros, no qual foi detectada uma provável lesão; e a termorregulação, onde indicou que os animais encontravam-se em desconforto térmico por calor. Diante dos resultados obtidos, pode-se concluir que o estabelecimento dos parâmetros fisiológicos e a utilização da câmera termográfica são importantes para balizarem o nível de esforço do treinamento a ser empregado em cavalos de salto e no auxilio da prevenção de futuras lesões. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Medicina Veterinária pt_BR
dc.title Determinação dos parâmetros fisiológicos e utilização da câmera termográfica para diagnosticar lesões em equinos de salto na cidade de João Pessoa - PB. pt_BR
dc.date.issued 2014-06
dc.description.abstract This study aimed to determine the physiological parameters of horses used in tests of classic show jumping in João Pessoa, Paraíba (PB), as well as use infrared thermography to diagnose possible lesions caused by physical training, thus promoting a training protocol best suited to these animals in order to attend the demands of the sport. For this, the following parameters were measured: heart rate (HR), respiratory rate (RR), rectal temperature (RT), and then nine projections were conducted on each animal with the help of the thermographic camera, resulting in the surface temperature (ST). These variables were measured before training (BT), after training (AT) and two hours after training (2h AT). Ten athletes’ equines were used, with the breeds Brasileiro de Hipismo (BH), French Saddle (FS), German Westphalen, Argentine Saddle and Mongrel, of which eight were males and two were females, aged 5-14 years old, staying in Hípica Thuany. All animals were jumping at the show jumping circuit in Paraiba with obstacle heights that vary according to each category, from 1 m to 1,30 m, which were divided in two groups, G1 and G2. The study was undertaken from September 2013 to May 2014 with a total of five surveys. The average values of the variable FC to G1 were: BT 33bpm; AT 62bpm; and 2h AT 34bpm. For G2 were: BT 31bpm; AT 65bpm; and 2h AT 35bpm. The average results for the FR G1 were: BT 23mpm; AT 57mpm; and 2h AT 27mpm. For G2 were: BT 24mpm; AT 71mpm; and 2h AT 26mpm. The mean TR G1 was variable: BT 37.4 º C; AT 38.9 ° C; 2h AT and 37.7 º C, as was to G2: BT 37.4 º C; PT 39.1 ° C; 2h AT and 37.7 º C. The TS variable was divided into: member evaluation, which was detected a probable injury; and thermoregulation, which indicated that the animals were in discomfort by heat. Based on these results, we can conclude that the establishment of the physiological parameters and the use of thermographic camera are important to quantify effort level of training to be used on horses jumping and assist in the prevention of future injuries. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24287
dc.date.accessioned 2022-04-04T13:04:39Z
dc.date.available 2014-04-04
dc.date.available 2022-04-04T13:04:39Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Equinos de salto - lesões pt_BR
dc.subject João Pessoa - PB - equinos de salto pt_BR
dc.subject Câmera termográfica pt_BR
dc.subject Lesões em equinos de salto pt_BR
dc.subject Cavalos atletas pt_BR
dc.subject Termografia pt_BR
dc.subject Hipismo pt_BR
dc.subject Injúrias musculoesqueléticas pt_BR
dc.subject Jumping horses - injuries pt_BR
dc.subject João Pessoa - PB - jumping horses pt_BR
dc.subject Thermographic camera pt_BR
dc.subject Injuries in jumping horses pt_BR
dc.subject Athletic horses pt_BR
dc.subject Thermography pt_BR
dc.subject Equestrianism pt_BR
dc.subject Musculoskeletal injuries pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator MENDONÇA, Múcio Fernando Ferraro de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Determination of physiological parameters and use of thermographic camera to diagnose lesions in jumping horses in João Pessoa – PB. pt_BR
dc.identifier.citation MENDONÇA, Múcio Fernando Ferraro de. Determinação dos parâmetros fisiológicos e utilização da câmera termográfica para diagnosticar lesões em equinos de salto na cidade de João Pessoa - PB. 2014. 51f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Medicina Veterinária, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24287 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta