Dépôt DSpace/Manakin

Avaliação ex vivo de diferentes designs de fixadores esqueléticos externos com polimetilmetacrilato em modelo experimental de úmero canino.

Afficher la notice abrégée

dc.creator.ID SILVA, L. F. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/4715392437008050 pt_BR
dc.contributor.advisor1 SÁ, Marcelo Jorge Cavalcanti de.
dc.contributor.advisor1ID SÁ, M. J. C. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2860610040748121 pt_BR
dc.contributor.referee1 GUEDES, Hitalo de Araújo.
dc.contributor.referee1ID GUEDES, H. A. pt_BR
dc.contributor.referee2 MEDEIROS, Lylian Karlla Gomes de.
dc.contributor.referee2ID MEDEIROS, L. K. G. pt_BR
dc.description.resumo Objetivou-se, avaliar as diferentes formas de utilizar os fixadores esqueléticos a partir uso do polimetilmetacrilato no intuito de reparar fratura em modelo experimental de úmero. Foram utilizado 15 peças, estudados modelos ósseos de úmero canino, os modelos foram coletados no Laboratório de Patologia Animal do Hospital Veterinário Universitário Prof. Dr. Ivon Macêdo Tabosa (HVUIMT), Universidade Federal de Campina Grande (UFCG), campus de Patos, Paraíba, Brasil. Foram dissecados úmeros de cães de médio porte encaminhados para exames de necrópsia, o critério adotado para inclusão no estudo foi o de animais entre 3 a 5 anos de idade, de ambos os sexos, sem raça definida, sem restrição de peso e que não apresentavam nenhuma alteração clínica endócrina, metabólica, infeciosa ou qualquer outra alteração que comprometesse a estrutura do esqueleto apendicular. Foram tomados cuidados para a coleta, dissecação e armazenamento dos ossos, causando o mínimo de alterações aos modelos ósseos para que o ensaio mimetizasse o mais próximo possível um ensaio mecânico com paciente in vivo, os mesmos autores ainda relatam que esses cuidados favorecem melhores resultados. Após este processo foi realizado fratura transversa em diáfise média de todos os ossos com auxílio de serra oscilatória, nesse momento os modelos ósseos foram divididos aleatoriamente em três grupos experimentais com cinco modelos ósseos cada: - Grupo 1 (G1): Foram confeccionados sistema de FEE do tipo I b, com dois pinos de Schunz de 4.5 mm inseridos no plano cranial do osso (um pino por fragmento ósseo) e conectados através de PMMA e dois pinos de Schunz de mesmo diâmetro inseridos no plano lateral do osso (um pino por fragmento ósseo) e conectados através de PMMA.-Grupo 2 (G2): Foram confeccionados sistema de FEE do tipo Tie-in, com quatro pinos de Schunz de 4.5 mm inseridos no plano lateral do osso (dois pinos por fragmento ósseo) e um pino intramedular de 4.5 mm, todos os pinos foram conectados com PMMA.-Grupo 3 (G3): Foram confeccionados sistema de FEE do tipo Tie-in, com dois pinos de Schunz de 4.5 mm inseridos no plano lateral do osso (um pino por fragmento ósseo) e um pino intramedular de 4.5 mm, todos os pinos foram conectados com PMMA. Durante o trabalho observou se que configurações de FEE do tipo I b possuem características mecânicas semelhantes a configurações do tipo Tie-in, sendo uma boa alternativa a morbidade pós-operatória observada em pacientes submetidos a designs Tie-in. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Medicina Veterinária pt_BR
dc.title Avaliação ex vivo de diferentes designs de fixadores esqueléticos externos com polimetilmetacrilato em modelo experimental de úmero canino. pt_BR
dc.date.issued 2019
dc.description.abstract Ex vivo evaluation of different designs of external skeletal fixators with polymethylmethacrylate in an experimental canine humerus model. The aim of this study was to evaluate the different ways of using skeletal fixators from the use of polymethylmethacrylate in order to repair a fracture in an experimental humerus model. Fifteen pieces were used, studying canine humerus bone models, the models were collected in the Laboratory of Animal Pathology of the Veterinary University Hospital Prof. Dr. Ivon Macêdo Tabosa (HVUIMT), Federal University of Campina Grande (UFCG), Patos campus, Paraíba, Brazil. Mice of medium-sized dogs referred for necropsy examinations were dissected, the criterion adopted for inclusion in the study was that of animals between 3 and 5 years of age, of both sexes, without a defined race, without weight restriction and that did not present no endocrine, metabolic, infectious, or any other change that compromises the structure of the appendicular skeleton. care was taken to the collection, dissection and storage of bones, causing minimal changes to the bone models for the test mimetizasse as close to a mechanical test in vivo patient, the same authors also report that this care promote better results. After this process was conducted in a transverse fracture shaft average of all bones with the aid of oscillating saw, at the moment the bone models were divided randomly into three groups of five each bone models: -Group 1 (G1): were prepared FEE system type Ib, with two Schunz pins of 4.5 mm inserted into the cranial level of the bone (a pin for bone fragment) and connected by PMMA and two Schunz pins of the same diameter inserted into the bone side view (a pin for fragment bone) and connected through PMMA. -Group 2 (G2): were prepared FEE system tie-in type with four pins Schunz 4.5 mm inserted into the bone side plane (two pins per bone fragment) and a 4.5 mm intramedullary pin, all the pins were connected with PMMA. -Group 3 (G3): were prepared FEE system of the type tie-in with two Schunz pins inserted into the 4.5mm bone side view (by a pin bone fragment) and a 4.5 mm intramedullary pin, all the pins were connected with PMMA. During the work, it was observed that FEE configurations of type I b have mechanical characteristics similar to Tie-in configurations, being a good alternative to postoperative morbidity o Tie-in, pino, fraturas bserved in patients submitted to Tie-in designs. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24638
dc.date.accessioned 2022-04-19T13:45:11Z
dc.date.available 2022-04-19
dc.date.available 2022-04-19T13:45:11Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Fraturas caninas pt_BR
dc.subject Fixadores esqueléticos externos pt_BR
dc.subject Pino pt_BR
dc.subject Biomaterias pt_BR
dc.subject Úmero canino pt_BR
dc.subject Hospital Veterinário CSTR UFCG pt_BR
dc.subject Ortopedia Veterinária pt_BR
dc.subject Polimetilmetacrilato pt_BR
dc.subject Canine fractures pt_BR
dc.subject External skeletal fixators pt_BR
dc.subject Pin pt_BR
dc.subject Biomaterials pt_BR
dc.subject Canine humerus pt_BR
dc.subject Veterinary Hospital CSTR UFCG pt_BR
dc.subject Veterinary Orthopedics pt_BR
dc.subject Polymethylmethacrylate pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Leonardo Flor da.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Ex vivo evaluation of different designs of external skeletal fixators with polymethylmethacrylate in an experimental canine humerus model. pt_BR
dc.identifier.citation SILVA, Leonardo Flor da. Avaliação ex vivo de diferentes designs de fixadores esqueléticos externos com polimetilmetacrilato em modelo experimental de úmero canino. 2019. 32f. Trabalho de Conclusão de Curso (Monografia), Curso de Bacharelado em Medicina Veterinária, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2019. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24638 pt_BR


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Chercher dans le dépôt


Recherche avancée

Parcourir

Mon compte