DSpace/Manakin Repository

Uso de geotecnologias na locação de torres para detecção de incêndios florestais.

Mostrar registro simples

dc.creator.ID ASSIS, F. R. V. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/2488286309033293 pt_BR
dc.contributor.advisor1 MENDONÇA, Izaque Francisco Candeia de.
dc.contributor.advisor1ID MENDONÇA, I. F. C. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0473200418393295 pt_BR
dc.contributor.referee1 SOUSA, Antônio Amador de.
dc.contributor.referee2 SILVA, Josuel Arcanjo da.
dc.description.resumo Os SIG’s constituem ótima ferramenta para implantação de torres para detecção de incêndios, pois possibilitam a manipulação de grande volume de informações. Neste sentido o objetivo do presente estudo foi identificar e gerar um mapa de risco de incêndios florestais, usar estas informações para identificar os locais ideais para implantação de torres de vigilância contra incêndios florestais e, por fim, avaliar a potencialidade do SIG (IDRISI Andes v. 15.0) para aplicação da metodologia proposta. O estudo foi realizado na microbacia do Rio do Saco, município de Santa Luzia – PB. Foram utilizados os softwares IDRISI Andes (Versão 15.0) e AutoCAD 2010, as imagens orbitais GLS 2005 do Landsat-5, sensor TM e ETM, ResourceSat, sensor “LIS3” e o Modelo Digital de Elevação do projeto ASTER GDEM. Os planos gerados foram os mapas de declividade, uso do solo e cobertura vegetal, orientação das encostas, altimetria, temperatura, precipitação e risco potencial de incêndio, que foi correlacionado com as cotas de maior altitude e a proximidade de estradas para alocação das torres. Os resultados mostraram que as três classes de maior risco de ocorrência de incêndios, quando somadas suas áreas de abrangência totalizaram 5863,1 ha (61,64 %), tendo a área um elevado potencial de risco de incêndio. Já com relação à locação das torres, a torre 1 (T1) proporcionou maior visualização (41,2 %) das áreas de risco alto, muito alto e extremo, relativo as demais torres individualmente. Já se tratando de duas torres simultâneas a combinação que apresentou maior área de visualização foi T1 + T5 (74,9%), com ganho de 20% se comparado à implantação apenas de T1. Os resultados traduzem êxito da metodologia na determinação dos locais ideais para instalação de torres de vigilância contra incêndios florestais, atendendo satisfatoriamente aos objetivos propostos, permitindo a indicação dos procedimentos metodológicos adotados em outras áreas da região semiárida do Nordeste brasileiro com características fisiográficas semelhantes à área avaliada nessa pesquisa. A utilização do SIG mostrou-se satisfatória, uma vez que suas rotinas foram capazes de atender, de forma rápida precisa, a todos os procedimentos requeridos para o trabalho. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Florestal pt_BR
dc.title Uso de geotecnologias na locação de torres para detecção de incêndios florestais. pt_BR
dc.date.issued 2013-02-27
dc.description.abstract The SIG's are a great tool for deployment of towers for fire detection, they allow the manipulation of large volumes of information. In this sense the objective of this study was to identify and generate a map of risk of forest fires, use this information to identify the ideal locations for deployment of watchtowers against wildfires and ultimately evaluate the potential of GIS (IDRISI Andes v . 15.0) for the proposed methodology. The study was conducted in the watershed of the Saco River in the city of Santa Luzia - PB. We used the IDRISI Andes software (Version 15.0) and AutoCAD 2010, 2005 GLS satellite images from Landsat-5, sensor TM and ETM, ResourceSat, sensor "LIS3" and Digital Elevation Model ASTER GDEM project. The plans were generated maps of slope, land use and vegetation cover, orientation of slopes, altitude, temperature, precipitation and potential fire hazard, which was correlated with the dimensions of higher altitude and proximity to roads for allocation of the towers. The results showed that the three classes of higher risk of fires, when added their coverage areas totaled 5863.1 ha (61.64%), with the area of high potential risk of fire. Now with regard to the lease of the towers, the tower 1 (T1) provided greater viewing (41.2%) of the areas of high risk, very high and extreme on the other towers individually. Already dealing with two towers simultaneous combination with the highest viewing area was T1 + T5 (74.9%), with a gain of 20% compared to the deployment of T1 only. The results reflect successful methodology in determining the ideal locations for installation of watchtowers against forest fires, satisfactorily meeting the proposed objectives, allowing the indication of the methodological procedures adopted in other areas of the semiarid region of northeastern Brazil with characteristics similar to the physiographic area evaluated this research. The use of GIS was satisfactory, since their routines were able to meet, quickly need in all procedures required for the job. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24754
dc.date.accessioned 2022-04-22T19:19:48Z
dc.date.available 2022-03-22
dc.date.available 2022-04-22T19:19:48Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Geotecnologias pt_BR
dc.subject Incêndios florestais pt_BR
dc.subject Torres - locação espacial pt_BR
dc.subject Geoprocessamento pt_BR
dc.subject Bacias hidrográficas pt_BR
dc.subject Sistema de informação geográfica pt_BR
dc.subject Torres de detecção de incêndio pt_BR
dc.subject Mapa de risco - incêndios florestais pt_BR
dc.subject Torres de vigilância - incêndios florestais pt_BR
dc.subject Software IDRISI Andes v.15.0 pt_BR
dc.subject Microbacia do Rio Saco - Santa Luzia - PB pt_BR
dc.subject Santa Luzia - PB - microbacia do Rio Saco pt_BR
dc.subject Rio Saco - Santa Luzia - PB pt_BR
dc.subject Imagens orbinais GLS 2005 pt_BR
dc.subject Landsat-5 pt_BR
dc.subject Geotechnologies pt_BR
dc.subject Forest fires pt_BR
dc.subject Towers - space lease pt_BR
dc.subject Geoprocessing pt_BR
dc.subject Watersheds pt_BR
dc.subject Geographic Information System pt_BR
dc.subject Fire detection towers pt_BR
dc.subject Risk map - forest fires pt_BR
dc.subject Watchtowers - forest fires pt_BR
dc.subject IDRISI Andes Software v.15.0 pt_BR
dc.subject Saco River Microbasin - Santa Luzia - PB pt_BR
dc.subject Santa Luzia - PB - Saco River microbasin pt_BR
dc.subject Saco River - Santa Luzia - PB pt_BR
dc.subject Orbinal Images GLS 2005 pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator ASSIS, Fellipe Ragner Vicente de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Using geotechnology on space towers for forest fire detection. pt_BR
dc.identifier.citation ASSIS, Fellipe Ragner Vicente de. Uso de geotecnologias na locação de torres para detecção de incêndios florestais. 2013. 43f. Trabalho de Conclusão de Curso (Monografia), Curso de Engenharia Florestal, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2013. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24754 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta