DSpace/Manakin Repository

Avaliação da bioatividade de ligas de NiTi tratadas a laser para aplicação em implantes dentários.

Mostrar registro simples

dc.creator.ID MOREIRA, A. M. A. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/3827178942982194 pt_BR
dc.contributor.advisor1 CATÃO, Carmem Dolores de Sá.
dc.contributor.advisor1ID CATÃO, C. D. S. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/7173639352326441 pt_BR
dc.contributor.referee1 GUEDES, Maria Carolina Bandeira Macena.
dc.contributor.referee1ID GUEDES, M. C. B. M. pt_BR
dc.contributor.referee2 RODRIGUES, Rachel de Queiroz Ferreira.
dc.contributor.referee2ID RODRIGUES, R. Q. F. pt_BR
dc.description.resumo As ligas de NiTi são amplamente utilizadas em dispositivos da área odontológica, como na Implantodontia, devido as suas propriedades de biocompatibilidade, memória de forma e superelasticidade. Assim, o presente estudo teve como objetivo avaliar a bioatividade e as características morfológicas de liga de NiTi (45,3% de Ni e 54,7% de Ti), tratadas a laser com e sem recobrimento de apatita. Dessa forma, as ligas de NiTi foram obtidas pela técnica Plasma Skull Push Pull, posteriormente as amostras foram tratadas superficialmente a laser (Yb:YAG) e pelo método biomimético em SBF-0 e SBF-6 (Simulated Body Fluid), ambas a 1,5 M. A análise de bioatividade foi realizada por meio da pesagem, espectroscopia por energia dispersiva de raios X (EDS) e microscopia eletrônica de varredura (MEV). As espectroscopias revelaram aumento na concentração de oxigênio e carbono após a ablação, favorecendo a difusão de átomos de oxigênio e formação de óxidos de titânio. Após a deposição da apatita pelo método biomimético em SBF-0 e 6, o recobrimento apresentou uma razão molar de Ca/P de aproximadamente 1,0, caracterizando a formação de apatitas de baixa cristalinidade. Pôde-se constatar que a associação da irradiação a laser e deposição química de apatitas pelo método biomimético em SBF-6, embora tenha demonstrado um melhor desempenho quanto à bioatividade e topografia das ligas, o ganho de massa não foi estatisticamente significativo ao nível de 5%. Tais propriedades podem contribuir para maior interação do biomaterial com o meio biológico e possível redução no tempo de osseointegração. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Odontologia pt_BR
dc.title Avaliação da bioatividade de ligas de NiTi tratadas a laser para aplicação em implantes dentários. pt_BR
dc.date.issued 2014-08-13
dc.description.abstract NiTi alloys are widely used in devices for dentistry, as in dental implants, due to their biocompatible, shape memory and superelasticity. Thus, the present study aimed to evaluate the bioactivity and the morphological characteristics of NiTi alloy (45.3% Ni and 54.7% Ti), treated with laser and uncoated apatite. Thus, the NiTi alloys were obtained by the technique Plasma Skull Push Pull, the samples were subsequently treated superficially laser (Yb: YAG) and the biomimetic method in SBF-0 and SBF-6 (Simulated Body Fluid), both 1,5 M. The bioactivity analysis was performed by weighing spectroscopy, energy dispersive X-ray (EDS) and scanning electron microscopy (SEM). The spectroscopy revealed increased concentration of oxygen and carbon after ablation, favoring the diffusion of oxygen atoms and formation of titanium oxides. After the biomimetic apatite deposition method on SBF-0 and 6, the coating had a molar ratio of Ca/P ratio of 1,0, characterizing the formation of low crystalline apatite. It could be observed that the combination of laser irradiation and chemical deposition of apatite by biomimetic method in SBF-6, but has shown a better performance in terms of bioactivity and topography of the alloy, the mass gain was not statistically significant at 5 %. These properties may contribute to greater interaction of the biomaterial with the biological environment and possible reduction in the time of osseointegration. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24815
dc.date.accessioned 2022-04-25T17:44:58Z
dc.date.available 2022-04-25
dc.date.available 2022-04-25T17:44:58Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Ligas de NiTi pt_BR
dc.subject Implantes dentários pt_BR
dc.subject Apatitas pt_BR
dc.subject Osseointegração pt_BR
dc.subject Implantodontia pt_BR
dc.subject Plasma Skull Push Pull pt_BR
dc.subject NiTi alloys pt_BR
dc.subject Dental implants pt_BR
dc.subject Apatites pt_BR
dc.subject Osseointegration pt_BR
dc.subject Implantology pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator MOREIRA, Anny Mirene Alves.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Bioactivity evaluation of laser-treated NiTi alloys for application in dental implants. pt_BR
dc.identifier.citation MOREIRA, Anny Mirene Alves. Avaliação da bioatividade de ligas de NiTi tratadas a laser para aplicação em implantes dentários. 2014. 62f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24815 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta