Avaliação de propriedades termomecânicas de fios de níquel-titânio aplicados na ortodontia.

Mostrar registro simples

dc.creator.ID OLIVEIRA, B. F. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/1908448824275615 pt_BR
dc.contributor.advisor1 MACENA, Maria Carolina Bandeira.
dc.contributor.advisor1ID MACENA, M. C. B. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0315428564273798 pt_BR
dc.contributor.referee1 CATÃO, Carmen Dolores de Sá.
dc.contributor.referee2 RODRIGUES, Rache de Queiroz Ferreira.
dc.description.resumo Em decorrência da diversidade de ligas disponíveis, com seus diversos métodos de fabricação, é importante ao ortodontista conhecer suas propriedades e as variáveis relacionadas, para planejar o tratamento e otimizar os resultados clínicos, assim como preservar a histofisiologia do periodonto do paciente. Dessa forma, o objetivo deste estudo foi avaliar e comparar in vitro as propriedades termomecânicas de fios ortodônticos superelásticos pré-contornados de níquel-titânio de duas marcas comerciais. Métodos: Foram utilizadas as marcas comerciais Morelli® (Grupo 1) e Orthometric® (Grupo 2), das quais obteve-se 5 amostras por grupo, onde foram submetidas aos ensaios de DMA (Análise Dinâmico-Mecânica) e DSC (Calorimetria Diferencial de Varredura). Os ensaios de DMA foram realizados no modo de flexão em três pontos, e os parâmetros utilizados foram: taxa de aquecimento de 5°C/min, na faixa de 30°C a 100°C, frequência de 1 Hz e amplitude de 5 μm. Para o DSC, os parâmetros foram: taxa de aquecimento/resfriamento de 5°C/min, na faixa de -60 °C a 120 °C, sob atmosfera dinâmica de ar e de nitrogênio (para resfriamento), com vazão de gás da ordem de 100 ml/min-1, sob pressão atmosférica. Após a realização dos ensaios, os dados obtidos foram tratados e analisados utilizando-se o software OriginPro 8.5®, obtendose, a partir do DMA, gráficos com as curvas de módulo de elasticidade e capacidade de amortecimento (tan δ) em função da temperatura e, a partir do DSC, gráficos mostrando as temperaturas de transformação de fase cristalina da liga. Para a análise das médias dos módulos de elasticidade das amostras, foi empregado o teste estatístico Teste-t de Student, com nível de significância de 5%. Resultados: O Teste-t de Student demonstrou que a diferença das médias dos módulos de elasticidade das amostras foi estatisticamente significante (p < 0,05). A rigidez de ambos os grupos aumentou em função do aumento da temperatura. À 37°C, temperatura normal intrabucal, o Grupo 1 evidenciou média de rigidez superior comparado ao Grupo 2, e ambos apresentaram-se na fase austenítica. Conclusões: Com os dados da pesquisa, pode-se concluir que mesmo as ligas com mesma característica de superelasticidade e ,possivelmente, semelhante composição química, houve diferença entre os módulos de elasticidade entre as marcas comerciais, sob as mesmas condições de estudo, onde o Grupo 1 apresentou maior rigidez quando comparado ao Grupo 2, característica essa que pode favorecer a um melhor desempenho clínico do primeiro grupo. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Odontologia pt_BR
dc.title Avaliação de propriedades termomecânicas de fios de níquel-titânio aplicados na ortodontia. pt_BR
dc.date.issued 2014
dc.description.abstract As a result of the diversity of available leagues, with his several manufacture methods, it is important to an ortodontista to know his properties and the connected variables, to plan the treatment and to optimize the clinical results, as well as to preserve the histofisiologia of the periodonto of the patient. In this form, the objective of this study valued and he compared in vitro the properties termomecânicas of threads ortodônticos superelastic daily pay gone of nickel-titanium of two commercial marks. Methods: The commercial marks Morelli® (Group 1) and Orthometric® (Group 2) were used, of which 5 samples were obtained by group, where they were subjected to the tests of DMA (Dynamical Mechanical Analysis) and DSC (Differencial Scanning Calorimetry). The tests of DMA were carried out in the flexing way in three points, and the used parameters were: tax of heating of 5°C/min, in the belt of 30°C to 100°C, 1 Hz frequency and amplitude of 5 μm. For the DSC, the parameters were: tax of heating/cooling of 5°C/min, in the belt of 60 °C to 120 °C, under dynamic atmosphere of air and of nitrogen (for cooling), with flow of gas of the order of 100 ml/min-1, under atmospheric pressure. After the realization of the tests, the obtained data were treated and analysed when is used the software OriginPro 8.5®, when printers are obtained, from the DMA, with the curves of module of elasticity and capacity of deadening (tan δ) in function of the temperature and, from the DSC, printers showing the temperatures of transformation of crystal clear phase of the league. For the analysis of the averages of the modules of elasticity of the samples, the statistical test was employed Test-t de Student, with level of signification of 5 %. Results: The Test-t de Student demonstrated that the difference of the averages of the modules of elasticity of the samples was statistically significant (p < 0,05). The rigidity of both groups increased in function of the increase of the temperature. To 37°C, intrabuccal normal temperature, the Group 1 showed average of superior rigidity up when 2 was compared to the Group, and both showed up in the austenitic phase. Conclusions: With the data of the inquiry, it is possible to end what even the leagues with the same characteristic of superelasticity and, possibly, similar chemical composition, existed difference between the elasticity modules between the commercial marks, under the same study conditions, where the Group 1 presented bigger rigidity when the Group 2, this characteristic that it can favor to a better clinical performance of the first group was compared to the group. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24823
dc.date.accessioned 2022-04-25T18:42:15Z
dc.date.available 2022-04-25
dc.date.available 2022-04-25T18:42:15Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Ortodontia pt_BR
dc.subject Pesquisa em Odontologia pt_BR
dc.subject Fios ortodônticos pt_BR
dc.subject Módulo de elasticidade pt_BR
dc.subject Ligas ortodônticas pt_BR
dc.subject Propriedades termomecânicas - fios ortodônticos pt_BR
dc.subject Orthodontics pt_BR
dc.subject Research in Dentistry pt_BR
dc.subject Orthodontic wires pt_BR
dc.subject Modulus of elasticity pt_BR
dc.subject Orthodontic alloys pt_BR
dc.subject Thermomechanical properties - orthodontic wires pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator OLIVEIRA, Bruno Firmino de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation of thermomechanical properties of nickel-titanium wires applied in orthodontics. pt_BR
dc.identifier.citation OLIVEIRA, Bruno Firmino de. Avaliação de propriedades termomecânicas de fios de níquel-titânio aplicados na ortodontia. 2014. 48f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2014. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/24823 pt_BR