DSpace/Manakin Repository

Cone morse x hexágono externo, vantagens e desvantagens no aspecto clíico: revisão de literatura.

Mostrar registro simples

dc.creator.ID SILVA, R. M. M. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/4462337110259030 pt_BR
dc.contributor.advisor1 RODRIGUES, Rodrigo Araújo.
dc.contributor.advisor1ID RODRIGUES, R. A. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/7538420607868266 pt_BR
dc.contributor.referee1 RODRIGUES, Rachel de Queiroz Ferreira.
dc.contributor.referee1ID RODRIGUES, R. Q. F. pt_BR
dc.contributor.referee2 RIBEIRO, Rodrigo Alves.
dc.contributor.referee2ID RIBEIRO, R. A. pt_BR
dc.description.resumo Na odontologia, as questões estéticas estão cada vez mais importantes. Os implantes dentários modernos surgiram a partir de pesquisas de Branemark e estão cada vez mais presentes no dia-a-dia clínico da área, sendo os do tipo cone morse e hexágono externo bastante difundidos. Os implantes são peças de titânio que se unem ao osso por meio de um mecanismo chamado osseointegração e cada sistema traz suas vantagens e desvantagens. A peri-implantite é uma infecção causada nos tecidos adjacentes ao implante devido ao acúmulo de biofilme por má higienização, que pode ser modificada por outros fatores, causando perda óssea, afetando estética e função dos implantes. Além dela, problemas como afrouxamento de parafuso e fratura também podem acometer os diversos sistemas de implantes. Avaliando Cone Morse e Hexágono externo em seus aspectos clínicos, foi possível concluir que o sistema CM se sobressai, segundo a bibliografia consultada. A presente revisão foi realizada entre o período de novembro de 2017 a julho de 2018, incluindo pesquisas, casos clínicos e também outras revisões de literatura encontradas nas plataformas Bireme, Pubmed e Scielo. Ela visou comparar, de acordo com uma revisão literária, os aspectos clínicos entre os sistemas cone morse e hexágono externo de implantes dentários. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Odontologia pt_BR
dc.title Cone morse x hexágono externo, vantagens e desvantagens no aspecto clíico: revisão de literatura. pt_BR
dc.date.issued 2018-07-18
dc.description.abstract In dentistry, aesthetic issues are increasingly important. Modern dental implants have emerged from Branemark researches and are increasingly present in the clinical dayto- day of the area, with the cone morse and external hexagons being quite widespread. Implants are titanium pieces that attach to the bone through a mechanism called osseointegration and each system brings its advantages and disadvantages. The periimplantite is an infection caused in the tissues adjacent to the implant due to the accumulation of biofilm by poor hygiene, which can be modified by other factors, causing bone loss, affecting aesthetics and function of the implants. In addition, problems such as loosening and fracture can also affect the various implant systems. Evaluating Cone Morse and external Hexagon in its clinical aspects was possible to conclude that the CM system excels according to the bibliography consulted. The present review was conducted between November 2017 and July 2018, including research, clinical cases and other literature reviews found on the Bireme, Pubmed and Scielo platform. It aimed to compare, according to a literary review, the clinical aspects between the cone morse and external hexagon systems of dental implants. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/25819
dc.date.accessioned 2022-06-20T16:57:00Z
dc.date.available 2022-06-20
dc.date.available 2022-06-20T16:57:00Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Implantodontia pt_BR
dc.subject Morse pt_BR
dc.subject Titânia pt_BR
dc.subject Osseointegração pt_BR
dc.subject Implantes dentários pt_BR
dc.subject Estética dentária pt_BR
dc.subject Peri-implantite pt_BR
dc.subject Cone morse e hexágono externo pt_BR
dc.subject Implantology pt_BR
dc.subject Osseointegration pt_BR
dc.subject Dental implants pt_BR
dc.subject Dental aesthetics pt_BR
dc.subject Peri-implantitis pt_BR
dc.subject Morse cone and external hexagon pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Randerson Mattheus Moura da.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Morse taper x external hexagon, advantages and disadvantages in the clinical aspect: literature review. pt_BR
dc.identifier.citation SILVA, Randerson Mattheus Moura da. Cone morse x hexágono externo, vantagens e desvantagens no aspecto clíico: revisão de literatura. 2018. 39f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2018. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/25819 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta