DSpace/Manakin Repository

Análise comparativa da precisão e confiabilidade de dois localizadores eletrônicos foraminais: um estudo in vitro.

Mostrar registro simples

dc.creator.ID NÓBREGA, W. F. S. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/1602521744449997 pt_BR
dc.contributor.advisor1 SARMENTO, Tássia Cristina de Almeida Pinto.
dc.contributor.advisor1ID SARMENTO, T. C. A. P. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/8780072808231578 pt_BR
dc.contributor.referee1 ROSENDO, Rosana Araújo.
dc.contributor.referee1ID ROSENDO, R. A. pt_BR
dc.contributor.referee2 RODRIGUES, Rachel de Queiroz Ferreira.
dc.contributor.referee2ID RODRIGUES, R. Q. F. pt_BR
dc.description.resumo Introdução: Atualmente, existe uma gama de localizadores eletrônicos disponíveis no mercado e, como era de se esperar, nem todos esses aparelhos são precisos na determinação do comprimento de trabalho. Objetivo: Realizar uma análise comparativa in vitro da precisão e confiabilidade de dois localizadores eletrônicos foraminais, na determinação do comprimento real do dente. Material e métodos: Foram utilizados no estudo 30 dentes extraídos. O comprimento real do dente foi mensurado com lima tipo K n°10 até o aparecimento da sua ponta rente ao forame, observado com lupa. Para mensuração eletrônica, foi utilizada base experimental preenchida com espuma floral e embebida em cloreto de sódio a 0,9%, na qual os dentes foram suportados. As mensurações foram realizadas com o Novapex e Joypex 5 em triplicata por dois examinadores previamente calibrados, tanto antes quanto após o preparo do terço cervical com brocas Gates Glidden. Os dados foram tabulados e analisados utilizando-se os testes t-Student e ANOVA one-way. Os localizadores foram classificados em Preciso, Aceitável, e Errôneo. Resultados: As médias de odontometria do Novapex e Joypex antes e após o preparo cervical diferiram minimamente entre si, não se observando diferenças estatísticas entre elas. A somatória dos escores preciso e aceitável, para o Novapex antes e após o preparo cervical foi de 79,9%, e para o Joypex, antes do preparo foi de 76,66% e após de 96,32, não havendo diferenças estatísticas entre os mesmos. Conclusão: Ambos os localizadores foram considerados capazes de determinar com precisão e confiabilidade o comprimento do canal radicular. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Saúde e Tecnologia Rural - CSTR pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Odontologia pt_BR
dc.title Análise comparativa da precisão e confiabilidade de dois localizadores eletrônicos foraminais: um estudo in vitro. pt_BR
dc.date.issued 2015-07-29
dc.description.abstract Introduction: Currently, there is a range of electronic locators on the market and, as was to be expected, not all of these devices are accurate in determining the working length. Objective: To conduct a comparative analysis in vitro accuracy and reliability of two electronic apex locators, in determining the real length of the tooth. Methods: Was used 30 extracted teeth in the study. The real length of the tooth was measured with a K file Nº 10 until the appearance of its tip close to the foramen, observed with magnifying glass. For electronic measurement was used experimental basis filled with floral foam and soaked in sodium chloride 0.9%, in which the teeth were supported. The measurements were made with Novapex and Joypex 5 in triplicate by two calibrated examiners, both before and after preparation of the cervical third with Gates Glidden drills. The data were tabulated and analyzed using the t-Student and ANOVA one-way tests. Locators were classified into Accurate, Acceptable, and Erroneous. Results: The average odontometry the Novapex and Joypex before and after cervical ripening differ minimally from each other, with no statistically significant differences between them. The sum of accurate and acceptable scores for Novapex before and after cervical ripening was 79.9%, and the Joypex before the preparation was 76.66% and after 96.32, with no statistical differences between the same. Conclusion: Both locators were considered capable of accurately and reliably determine the length of the root canal. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26045
dc.date.accessioned 2022-06-29T18:10:41Z
dc.date.available 2022-06-29
dc.date.available 2022-06-29T18:10:41Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Localizadores eletrônicos foraminais pt_BR
dc.subject Estudo in vitro pt_BR
dc.subject Odontometria pt_BR
dc.subject Endodontia pt_BR
dc.subject Ápice dentário pt_BR
dc.subject Electronic foraminal locators pt_BR
dc.subject In vitro study pt_BR
dc.subject Odontometry pt_BR
dc.subject Endodontics pt_BR
dc.subject Tooth apex pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator NÓBREGA, Waleska Fernanda Souto.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Comparative analysis of the accuracy and reliability of two electronic foraminal locators: an in vitro study. pt_BR
dc.identifier.citation NÓBREGA, Waleska Fernanda Souto. Análise comparativa da precisão e confiabilidade de dois localizadores eletrônicos foraminais: um estudo in vitro. 2015. 54f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26045 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta