dc.description.resumo |
As resinas compostas ou compósitos representam os materiais restauradores mais
utilizados para reabilitação de cavidades dentárias em dentes anteriores. Para tal
necessitam em sua composição de partículas de carga que proporcionem melhor
lisura superficial, facilitando os procedimentos de polimento, ao mesmo tempo que
contribuem para o aumento na resistência mecânica. O objetivo deste estudo foi
comparar duas unidades de fotopolimerização (LED Optilight ® - Gnatus – e LED
Olsen) de compósitos utilizadas na Clínica-Escola de Odontologia da UFCG/Patos
através da mensuração da resistência à compressão, variando a distância de
fotopolimerização. Foram confeccionados 60 corpos de prova, sendo 30 de cada
unidade estudada usando distâncias pré-determinadas, de acordo com ISO 4049, e
estes foram submetidos a mensuração da Dureza Vickers, após a polimerização,
variando a distância da ponteira do fotopolimerizador em relação ao corpo de
prova. Os dados foram tabulados e analisados no software SPSS (versão 21) e
após as análises não paramétricas de Kruskal-Wallis e testes de Mann-whitney,
aceitou-se como significante um p ≤ 0,05. Após a análise estatística, foi observada
diferença estatística significante para a unidade de fotopolimerização do tipo LED
Optilight ® (Gnatus), nos casos em que foi empregada para a distância de 3mm
(D3), nas comparações com D1 e D2. Sendo assim, pode-se concluir que o
afastamento da ponteira da unidade de fotopolimerização pode interferir
negativamente na dureza dos compósitos utilizados para procedimentos
restauradores. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Saúde e Tecnologia Rural - CSTR |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Odontologia |
pt_BR |
dc.title |
Avaliação da microdureza Vickers de um compósito variando a distância e a unidade de fotopolimerização. |
pt_BR |
dc.date.issued |
2015-11-03 |
|
dc.description.abstract |
Composite or composite resin restorative materials represent the most commonly
used for rehabilitation of dental cavities in anterior teeth. To this need in the
composition of filler particles which provide improved surface smoothness, making
the polishing procedure, while contributing to the increase in the mechanical strength.
The aim of this study was to compare two units ((LED Optilight ® - Gnatus – e LED Olsen) curing of composites used in the School Clinic of Dentistry UFCG / Ducks by
measuring the compressive strength, varying the distance curing. 60 specimens,
each being studied unit 30 using predetermined distances were prepared according
to ISO 4049, and these were subjected to measurement of Vickers hardness after
polymerization, varying the distance of the tip from curing to the body proof. Data
were analyzed with SPSS software (version 21) and after the nonparametric Kruskal-
Wallis analysis and Mann-Whitney tests, was accepted as significant, p ≤ 0.05.After
statistical analysis, statistically significant differences for unit type LED curing
Optilight® (Gnatus), where it was used for the distance of 3mm (D3), in comparison
with D1 and D2 was observed. Thus, it can be concluded that removal of the probe
unit photopolymerization can adversely affect the hardness of the composites used in
dentistry procedures. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26094 |
|
dc.date.accessioned |
2022-06-30T18:56:07Z |
|
dc.date.available |
2022-06-30 |
|
dc.date.available |
2022-06-30T18:56:07Z |
|
dc.type |
Trabalho de Conclusão de Curso |
pt_BR |
dc.subject |
Resinas compostas |
pt_BR |
dc.subject |
Microdureza Vickers |
pt_BR |
dc.subject |
Fotopolimerização do tipo LED |
pt_BR |
dc.subject |
Clínica Escola de Odontologia - CSTR UFCG |
pt_BR |
dc.subject |
Software SPSS |
pt_BR |
dc.subject |
Composite resins |
pt_BR |
dc.subject |
Vickers Microhardness |
pt_BR |
dc.subject |
LED-type light curing |
pt_BR |
dc.subject |
Dental School Clinic - CSTR UFCG |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
SIQUEIRA, Dayane de Souza. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Evaluation of Vickers microhardness of a composite varying the distance and the light curing unit. |
pt_BR |
dc.identifier.citation |
SIQUEIRA, Dayane de Souza. Avaliação da microdureza Vickers de um compósito variando a distância e a unidade de fotopolimerização. 2015. 47f. Trabalho de Conclusão de Curso (Artigo), Curso de Bacharelado em Odontologia, Centro de Saúde e Tecnologia Rural, Universidade Federal de Campina Grande - Patos - Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26094 |
pt_BR |