DSpace/Manakin Repository

Uma metodologia baseada em modelo para geração de recomendações de controle do balão intra-aórtico.

Mostrar registro simples

dc.creator.ID LUCENA, M. C. pt_BR
dc.creator.ID COSTA LUCENA, MATEUS. pt_BR
dc.creator.ID LUCENA, MATEUS C. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/9694230124879374 pt_BR
dc.contributor.advisor1 LIMA, Antonio Marcus Nogueira.
dc.contributor.advisor1ID LIMA, A. M. N. pt_BR
dc.contributor.advisor1ID Lima, A.M.N. pt_BR
dc.contributor.advisor1ID LIMA AMN. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/2237395961717699 pt_BR
dc.contributor.advisor2 CORDEIRO, Thiago Damasceno.
dc.contributor.advisor2ID CORDEIRO, T. D. pt_BR
dc.contributor.advisor2ID CORDEIRO, THIAGO. pt_BR
dc.contributor.advisor2ID CORDEIRO, T.D. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/2971153330790431 pt_BR
dc.contributor.referee1 QUEIROZ, Wamberto José Lira.
dc.contributor.referee1ID QUEIROZ, Wamberto José Lira de pt_BR
dc.contributor.referee1ID Queiroz, Wamberto J. L. pt_BR
dc.contributor.referee1ID Queiroz, Wamberto J L. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/7663004390139625 pt_BR
dc.contributor.referee2 SANTOS, João Batista Morais dos.
dc.contributor.referee2ID SANTOS, J. B. M. pt_BR
dc.contributor.referee2Lattes http://lattes.cnpq.br/4011086761146410 pt_BR
dc.description.resumo O balão intra- aortico (BIA) é um desportivo mecânica de assistência cardíaca (DMAC), de aplicabilidade temporária, utilizando para aumentar o fluxo de sangue nas artérias do músculo cardíaco (artérias coronária). O BIA é indicado principalmente para assistência em quadros de falência ventricular esquerda e choque cardiogênico ( incapacidade do músculo cardíaco em fornecer debido adequado às necessidades do organismo). Os sistemas de controle do BIA monitoram a condição do paciente, calculam um índice de desempenho e aplicam continuamente um algoritmo de controle capaz de levar funcionamento do sistema a um ponto ótimo de operação. Para avaliar a corretude fisiológica de operação BIA, os sistemas de controle observam tipicamente os níveis de pressão diastólica. O presente trabalho propõe uma metodologia baseada em modelos 0D que permite avaliar a associação de índices de pulsatilidade na qualificação de desempenho fisiológico relativa á utilização do BIA. Os resultados obtidos sugerem que os índices de Pulsatilidade PP,DP e EEP podem ser utilizados para gerar opções de controle em compromisso com objetivos clínicos do BIA. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica pt_BR
dc.title Uma metodologia baseada em modelo para geração de recomendações de controle do balão intra-aórtico. pt_BR
dc.date.issued 24-04-2019
dc.description.abstract The intra-aortic balloon (IAB) is a mechanical sport of cardiac assistance (DMAC), of temporary applicability, used to increase the flow of blood in the arteries of the cardiac muscle (coronary arteries). The BIA is mainly indicated for assistance in cases of left ventricular failure and cardiogenic shock (inability of the heart muscle to supply adequate debt to the body's needs). BIA control systems monitor the patient's condition, calculate a performance index, and continuously apply a control algorithm capable of bringing the system to an optimal operating point. To assess the physiological correctness of BIA operation, control systems typically look at diastolic pressure levels. The present work proposes a methodology based on 0D models that allows evaluating the association of pulsatility indices in the qualification of physiological performance related to the use of BIA. The results obtained suggest that the PP, DP and EEP Pulsatility indices can be used to generate control options in line with the clinical objectives of the BIA. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26830
dc.date.accessioned 2022-08-31T23:24:18Z
dc.date.available 2022-08-31
dc.date.available 2022-08-31T23:24:18Z
dc.type Dissertação pt_BR
dc.subject Engenharia Elétrica pt_BR
dc.subject Balão Intra-Aórtico pt_BR
dc.subject Processamento da Informação pt_BR
dc.subject Indices de Pulsatilidade pt_BR
dc.subject Electrical engineering pt_BR
dc.subject Intra-Aortic Balloon pt_BR
dc.subject Processing of Information pt_BR
dc.subject Pulsatility Indices pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator LUCENA, Mateus Costa.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative A model-based methodology for generating intra-aortic balloon control recommendations. pt_BR
dc.identifier.citation LUCENA, Mateus Costa. Uma metodologia baseada em modelo para geração de recomendações de controle do balão intra-aórtico. 2019. 99 fl. Dissertação (Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2019. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta