Aprimoramento da inspeção visual de isoladores poliméricos por termografia e campo elétrico.

Mostrar registro simples

dc.creator.ID DINIZ, L. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0970506061860633 pt_BR
dc.contributor.advisor1 COSTA, Edson Guedes da.
dc.contributor.advisor1ID COSTA, E. G. pt_BR
dc.contributor.advisor1ID COSTA, EDSON G. pt_BR
dc.contributor.advisor1ID COSTA, E.G. DA. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3930289115658143 pt_BR
dc.contributor.advisor2 FERREIRA, Tarso Vilela.
dc.contributor.advisor2ID FERREIRA, T. V. pt_BR
dc.contributor.advisor2ID FERREIRA, TARSO V. pt_BR
dc.contributor.advisor2ID FERREIRA, TARSO. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/9395719025602516 pt_BR
dc.contributor.referee1 FREIRE, Raimundo Carlos Silvério.
dc.contributor.referee1ID FREIRE, R. C. S. pt_BR
dc.contributor.referee1ID FREIRE, R. pt_BR
dc.contributor.referee1ID Freire, Raimundo C. S. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/4016576596215504 pt_BR
dc.contributor.referee2 GERMANO, André Dantas.
dc.contributor.referee2ID GERMANO, A. D. pt_BR
dc.contributor.referee2ID GERMANO, André Dantas. pt_BR
dc.contributor.referee2ID Germano, André D. pt_BR
dc.contributor.referee2Lattes http://lattes.cnpq.br/5861671113603396 pt_BR
dc.description.resumo Este trabalho apresenta uma investigação da correlação entre temperatura e campo elétrico para o aprimoramento da inspeção de isoladores poliméricos. Amostras de isoladores poliméricos de 138 kV, íntegras e com defeitos, foram submetidos a ensaios elétricos e medições termográficas. Isoladores retirados do campo foram submetidos a ensaios em sete níveis de tensão aplicada e as medições termográficas foram realizadas após o equilíbrio térmico ser estabelecido. Os isoladores poliméricos foram modelados e simulações computacionais de campo elétrico foram realizadas nas regiões de interesse. Os resultados das medições termográficas, realizadas durante os ensaios, mostraram elevações de temperatura maiores na região próxima ao terminal fase, quando os defeitos estão presentes. Os resultados das simulações computacionais dos isoladores sem defeitos externos não apresentaram distorções de campo elétrico. A análise dos isoladores com defeitos mostrou que o campo elétrico sofre distorções e sua intensidade depende da configuração do defeito e da posição dos defeitos, corroborando com as medições de temperatura. Os resultados indicam que existe uma tendência de crescimento da temperatura nos pontos onde o campo elétrico é mais intenso (furos superficiais). pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica pt_BR
dc.title Aprimoramento da inspeção visual de isoladores poliméricos por termografia e campo elétrico. pt_BR
dc.date.issued 2019-03-25
dc.description.abstract This work presents an evaluation of the correlation between temperature and electric field to the improvement of polymeric insulators inspection. Samples of 138 kV polymeric insulators, intact and defectives, were submitted to electrical tests and thermographic measurements. Thus, the insulators removed from transmission lines were submitted to seven level of applied voltage and the thermographic measurements were realized once thermal equilibrium was established. The polymeric insulators were modeled and computational simulations of electric field were performed in the regions of interest. The results of the thermographic measurements, performed during the tests, showed higher temperature increases near the phase, when the defects are present. The results of the computational simulations of the insulators without external defects showed no electric field distortions. The analysis of defective insulators revealed that the electric field is distorted and its intensity depends on the defects’ configuration and position, corroborating with the temperature measurements. The results indicate the existence of a growth trend of the temperature at the points where the electrical field is more intense (superficial holes). pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/26987
dc.date.accessioned 2022-09-06T20:04:13Z
dc.date.available 2022-09-06
dc.date.available 2022-09-06T20:04:13Z
dc.type Dissertação pt_BR
dc.subject Isoladores poliméricos pt_BR
dc.subject Termografia pt_BR
dc.subject Cálculo de campo elétrico pt_BR
dc.subject Inspeções termográficas pt_BR
dc.subject Inspeção visual pt_BR
dc.subject Processamento de Energia pt_BR
dc.subject Polymeric insulators pt_BR
dc.subject Thermography pt_BR
dc.subject Electric field calculation pt_BR
dc.subject Thermographic inspections pt_BR
dc.subject Visual inspection pt_BR
dc.subject Energy Processing pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator DINIZ, Larissa.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Improvement of visual inspection of polymeric insulators by thermography and electric field. pt_BR
dc.identifier.citation DINIZ, Larissa. Aprimoramento da inspeção visual de isoladores poliméricos por termografia e campo elétrico. 2019. 99 fl. Dissertação (Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2019. pt_BR