DSpace/Manakin Repository

Uso eficiente de água em campus universitário: o caso da Universidade Federal de Campina Grande.

Mostrar registro simples

dc.creator.ID GOMES, V. L. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/4808998049519275 pt_BR
dc.contributor.advisor1 RIBEIRO, Márcia Maria Rios.
dc.contributor.advisor1ID RIBEIRO, M. M. R. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4564679783610341 pt_BR
dc.contributor.advisor2 BARBOSA, Dayse Luna.
dc.contributor.advisor2ID BARBOSA, D. L. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/7376198442355112 pt_BR
dc.contributor.referee1 SIMÕES, Vicemário.
dc.contributor.referee2 FEITOSA, Patrícia Hermínio Cunha.
dc.description.resumo O consumo de água na zona urbana tem apresentado índice crescente devido, principalmente, ao aumento populacional seguido da falta de planejamento e infra-estrutura na ocupação territorial. Logo a conservação passa a ser ferramenta primordial no processo de gestão da demanda de água (GDA). Estudos afirmam que o desperdício de água ocasionado pelas perdas por vazamentos e pelo mau uso é de grande magnitude no setor público, no qual o usuário não é o responsável direto pelo pagamento da conta de água, não possuindo assim estímulo para o uso racional da água e dos equipamentos. Diversos empreendimentos públicos e privados já estão implantando programas de uso racional de água em suas instalações, motivados pela necessidade de reduzir o consumo e os custos. O objetivo deste trabalho é fornecer subsídios para um futuro planejamento do uso eficiente da água para o campus Campina Grande da Universidade Federal de Campina Grande (UFCG). Esta pesquisa, realizada no referido local, diagnosticou um crescimento demográfico de 67,5% em apenas nove anos e um acréscimo de 128,09% do volume de água consumido no mesmo período. A partir do levantamento de campo nas 135 edificações da Instituição, verificou-se que dos 1923 pontos de consumo de água, 11,02% dos aparelhos apresentam patologias devido à falta de manutenção nos sistemas prediais. Distinguindo as atividades desenvolvidas pela comunidade universitária, estimou-se o consumo mensal de água nos usos sanitários (3.588,82 m3), nas perdas ocasionadas pelos vazamentos (401,59 m3), limpeza das edificações (45,01 m3), cozinhas e Restaurante Universitário (RU) (1.265,00 m3) e no processo de destilação (77,84 m3), estando o excedente distribuído nas construções civis, consumo laboratorial, rega dos jardins, experimentos desenvolvidos nas estufas, entre outros. Devido à carência da medição setorizada e práticas de monitoração torna-se cada vez mais difícil a detecção de vazamentos internos e desperdícios expressivos. Portanto, devem ser instituídas medidas de gestão viáveis para os locais que apresentaram os maiores índices de consumo, possibilitando assim a elaboração de um plano de uso racional de água para a UFCG. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil. pt_BR
dc.title Uso eficiente de água em campus universitário: o caso da Universidade Federal de Campina Grande. pt_BR
dc.date.issued 2013
dc.description.abstract The water consumption in urban áreas has shown an increasing rate due mainly to population growth followed by lack of planning and infrastructure on land use. Conservation soon becomes the primary tool in the process of water demand management (WDM). Studies claim that the waste caused by the losses of leakage and misuse is of great magnitude in the public sector, where the user is not directly responsible for paying the water bill, have no incentive for the racional use of water and equipament. Several public and private enterprises are already implementing programs of rational use of water in their facilities, motivated by the need to reduce consumption and amounts spent. The objective of this work is provide subsidies for future planning of efficient use of water for Campina Grande campus of the Campina Grande Federal University (UFCG). This research, accomplished on the campus, diagnosed a population growth of 67.5% in just nine years and an increase of 128.09%) in the water consumed in the same period. In the field survey of the 135 buildings of the Institution, it was found that from 1923 points of water consumption, 11.02% of appliances show pathologies due to lack of maintenance on building systems. Distinguishing the activities of the university community, was estimated monthly consumption of water in sanitary uses (3588.82 m3), loss caused by leaks (401.59 m3), cleaning of buildings (45.01 m3), kitchens and University Restaurant (RU) (1265.00 m3) and the distillation process (77.84 m3), while the surplus distributed in civil construction, laboratory consumption, irrigation of gardens, experiments conducted in greenhouses, among others. Due to the lack of sectorial sub metering and monitoring it becomes increasingly difficult to detect internai leaks and significant waste. Therefore, measures should be imposed for viable management for sites that have the highest rates of consumption, thus enabling the development of the plan for the rational use of water for UFCG. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2737
dc.date.accessioned 2019-02-08T15:53:00Z
dc.date.available 2019-02-08
dc.date.available 2019-02-08T15:53:00Z
dc.type Dissertação pt_BR
dc.subject Uso eficiente de água pt_BR
dc.subject Campus universitário - uso da água pt_BR
dc.subject Universidade Federal de Campina Grande - Uso eficiente da água pt_BR
dc.subject Uso racional da água pt_BR
dc.subject Gestão da demanda de água pt_BR
dc.subject Desperdício de água pt_BR
dc.subject Manutenção em sistema hidráulico predial pt_BR
dc.subject Gerenciamento de demanda de água pt_BR
dc.subject Reuso de água pt_BR
dc.subject Programa Nacional de Combate ao Desperdício de Água pt_BR
dc.subject Consumo de água - universidade pt_BR
dc.subject Sistema de abastecimento de água - UFCG pt_BR
dc.subject Rational use of water pt_BR
dc.subject Water demand management pt_BR
dc.subject Waste of water pt_BR
dc.subject Water reuse pt_BR
dc.subject Water consumption - university pt_BR
dc.subject Maintenance in building hydraulic system pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator GOMES, Viviane Lucena.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Efficient use of water in university campuses: the case of the Federal University of Campina Grande. pt_BR
dc.description.sponsorship Capes pt_BR
dc.identifier.citation GOMES, Viviane Lucena. Uso eficiente de água em campus universitário: o caso da Universidade Federal de Campina Grande. 2013. 116f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Paraíba - Brasil, 2013. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/2737 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta