Modelagem computacional da distribuição de variáveis ambientais em aviário ventilado à pressão negativa.

Mostrar registro simples

dc.creator.ID CUNHA, G. C. A. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/6749829919471640 pt_BR
dc.contributor.advisor1 LOPES NETO, José Pinheiro.
dc.contributor.advisor1ID LOPES NETO, J. P. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/1800101850675185 pt_BR
dc.contributor.referee1 FREIRE, Elias Antonio.
dc.contributor.referee1ID FREIRE, E. A. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/4090558218076955 pt_BR
dc.contributor.referee2 NASCIMENTO, José Wallace Barbosa do.
dc.contributor.referee2ID NASCIMENTO, J. W. B. pt_BR
dc.contributor.referee2Lattes http://lattes.cnpq.br/9274991135144621 pt_BR
dc.contributor.referee3 FURTADO, Dermeval Araújo.
dc.contributor.referee3ID FURTADO, D. A. pt_BR
dc.contributor.referee4 PEREIRA, Valéria Peixoto Borges.
dc.contributor.referee4ID PEREIRA, V. P. B pt_BR
dc.description.resumo No Brasil, o emprego de sistemas de condicionamento artificial em pressão negativa em galpões avícolas está se tornando cada vez mais comum e, na Paraíba, ainda que a passos mais lentos, vem sendo incorporado por viabilizar a correção do microclima no interior de aviários. No entanto, pesquisas desenvolvidas na área de Construções Rurais e Ambiência apontam para a necessidade de melhoria da eficiência desses sistemas vez que identificam a distribuição heterogênea do ar ao longo das instalações e a inadequação dos dados ambientais internos às faixas recomendadas para o conforto térmico de aves adultas, especialmente nos períodos mais quentes do dia. Diante do exposto, avaliou-se a eficiência de diferentes arranjos construtivos de aviários para frangos de corte, ventilados à pressão negativa, por meio da análise da distribuição da temperatura do ar (Tar), umidade relativa (UR) e velocidade do vento (Vv) e da caracterização do ambiente térmico em função do Índice de temperatura, umidade e velocidade do ar (ITUV). Para tanto, instrumentou-se um galpão para coleta de dados de campo e diagnóstico de suas instalações quanto ao conforto térmico interno; gerou-se um modelo computacional de referência baseado neste galpão, por meio do software Autodesk CFD 2016; validou-se esse modelo; testaram-se três diferentes arranjos de coberta (TiFiA- baseado no protótipo, com forro paralelo à cobertura inclinada e aletas, TiFisA- semelhante à TiFiA, excluindo-se as aletas e TiFh- similar à TiFisA, com forro horizontal); selecionou-se aquele mais eficiente e combinou-se à dois arranjos de painéis evaporativos (TiFisA20L e TiFisA40L, com 20% e 40% da área dos painéis voltadas à Leste, respectivamente). Concluiu-se que: segundo ITUV, o galpão instrumentado, entre 12 e 14 h, não proveu conforto às aves adultas alojadas, com valores de Tar, UR e Vv não pertinentes às faixas recomendadas; o modelo CFD para TiFisA foi validado com médias de Tar coletadas em campo de 27,75 ± 1,35 oC e simuladas de 27,85 ± 0,55 oC, médias de UR coletadas de 83% ± 12% e simuladas de 78% ± 3% e médias das Vv coletadas de 2,35 ± 1,35 m.s-1 e simuladas de 2,50 ± 1,50 m.s-1; dentre os tratamentos de coberta testados, TiFisA mostrou ser o mais adequado ao conforto das aves em função do padrão de distribuição da Tar e da Vv; e dentre todos os arranjos simulados, TiFisA mostrou ser o mais adequado ao conforto das aves em função do padrão de distribuição da Tar. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia de Agrícola pt_BR
dc.title Modelagem computacional da distribuição de variáveis ambientais em aviário ventilado à pressão negativa. pt_BR
dc.date.issued 2017-02
dc.description.abstract In Brazil, the use of artificial conditioning systems in negative pressure in poultry houses is becoming increasingly common and in Paraiba, although at a slower pace, has been incorporated for making possible the correction of the microclimate inside aviaries. However, researches developed in the area of Rural Constructions and Ambience indicate the need to improve the efficiency of these systems instead of identifying the heterogeneous distribution of air throughout the building and the inadequacy of internal environmental data to the recommended ranges for the thermal comfort of broilers especially in the hottest times of the day. For these reasons, the efficiency of different constructive arrangements was evaluated in broilers houses, ventilated at negative pressure, by analyzing the distribution of air temperature (Tar), relative humidity (UR) and wind speed (Vv) and characterization of the thermal environment using the Temperature, Humidity and Air Velocity Index (ITUV). For that, a poultry house was instrumented for field data collection and diagnosis of its internal thermal comfort facilities; a computer model of reference was generated based on this aviary, using the software Autodesk CFD 2016; this model was validated; Three different cover arrangements (TiFiA- based on the prototype, with ceiling parallel to the inclined cover and fins, TiFisA- similar to TiFiA, excluding fins and TiFh- similar to TiFisA, with horizontal ceiling) were tested; the most efficient cover arrangement was selected and combined with two evaporative panel arrangements (TiFisA20L and TiFisA40L, with 20% and 40% of the area of the panels facing the East, respectively). It was concluded that: according to ITUV, the instrumented aviary, between 12 and 14 h, did not provide comfort to the adult poultrys housed, with Tar, UR and Vv values not pertinent to the recommended ranges; the CFD model for TiFisA was validated with Tar averages of 27.75 ± 1.35 oC collected in the field and simulated ones were 27.85 ± 0.55 oC, UR mean values of 83% ± 12% collected and simulated ones of 78% ± 3% and Vv means values of 2.35 ± 1.35 m.s-1 collected and simulated ones were of 2.50 ± 1.50 m.s-1; among the tested cover treatments, TiFisA showed to be the most adequate to the comfort of the broilers according to the distribution pattern of Tar and Vv; and among all the simulated arrangements, TiFisA was shown to be the most suitable for the comfort of the broilers according to the Tar distribution pattern. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28076
dc.date.accessioned 2022-11-29T12:32:25Z
dc.date.available 2022-11-29
dc.date.available 2022-11-29T12:32:25Z
dc.type Tese pt_BR
dc.subject Aviário ventilado à pressão negativa pt_BR
dc.subject Negative pressure ventilated poultry house pt_BR
dc.subject Construções rurais e ambiência pt_BR
dc.subject Rural buildings and ambience pt_BR
dc.subject Modelagem computacional pt_BR
dc.subject Computational modeling pt_BR
dc.subject Variáveis ambientais - aviário pt_BR
dc.subject Environmental variables - aviary pt_BR
dc.subject Bioclimatologia pt_BR
dc.subject Bioclimatology pt_BR
dc.subject Conforto térmico pt_BR
dc.subject Thermal comfort pt_BR
dc.subject Instalações avícolas - ambiência pt_BR
dc.subject Poultry facilities - ambience pt_BR
dc.subject Ambiência nas instalações avícolas pt_BR
dc.subject Ambience in poultry facilities pt_BR
dc.subject Fisiologia da ave pt_BR
dc.subject Bird physiology pt_BR
dc.subject Sensores de vento pt_BR
dc.subject Wind sensors pt_BR
dc.subject Simulações CFD pt_BR
dc.subject CFD simulations pt_BR
dc.subject Arranjos construtivos pt_BR
dc.subject Constructive arrangements pt_BR
dc.subject Validação de modelos pt_BR
dc.subject Model validation pt_BR
dc.subject Avicultura - ambiência pt_BR
dc.subject Poultry - ambience pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator CUNHA, Gisele Caldas de Araújo.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Computational modeling of the distribution of environmental variables in negative pressure ventilated aviary. pt_BR
dc.identifier.citation CUNHA, Gisele Caldas de Araújo. Modelagem computacional da distribuição de variáveis ambientais em aviário ventilado à pressão negativa. 2017. 133f. (Tese de Doutorado) Programa de Pós-Graduação em Engenharia Agrícola, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Paraíba - Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28076 pt_BR