DSpace/Manakin Repository

Desempenho e eficiência térmica de placas tipo sanduíche e eva + resíduos como forro de cobertura.

Mostrar registro simples

dc.creator.ID COSTA, R. F. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/4757267267064742 pt_BR
dc.contributor.advisor1 LOPES NETO, José Pinheiro.
dc.contributor.advisor1ID LOPES NETO, J. P pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/1800101850675185 pt_BR
dc.contributor.referee1 MELO, Fernanda Fernandes de.
dc.contributor.referee2 BORGES, Valeria Peixoto.
dc.description.resumo O resíduo de polímeros de EVA (Etileno-Acetato de Vinila) possui características adequadas para propósito de reciclagem, transformando-os em agregados leves, que podem trazer benefícios ao ambiente construído, como, por exemplo, o seu aproveitamento na forma de isolante térmico para forros, como coberta. O presente trabalho foi desenvolvido com o objetivo de avaliar o desempenho e eficiência térmica de forros utilizando-se de partículas de EVA + resíduos como placas sanduíche em coberturas de modelos reduzidos. A pesquisa foi realizada na área experimental do LaCRA – Laboratório de Construções Rurais e Ambiência da UFCG, Campina Grande - PB, entre os meses de julho e dezembro de 2014. Foram construídos 5 modelos reduzidos, utilizando telhas de fibrocimento, associados a 4 tipos de forros, mas um sem uso de forro (tratamento testemunha). Os forros testados eram compostos de placas de EVA, placas de EVA + resíduos da indústria de papel e celulose (RPC), placas de EVA + resíduos da indústria madeireira (RM) e placas de EVA+ resíduos cerâmicos (RC). As variáveis coletadas foram “temperatura de bulbo seco e úmido” e “umidade relativa do ar”, através de termopares, armazenados em sistema de aquisição de dados Campbell CR1000; para as variáveis do ambiente externo, foram medidas as temperaturas do bulbo (seco e úmido) e a velocidade do ar. Foram analisadas as propriedades térmicas dos forros, através dos cálculos da resistência térmica, transmitância térmica, capacidade térmica, atraso térmico e do fator solar. Este estudo comprovou o bom desempenho térmico do forro composto apenas de EVA como isolante térmico, que apresentou elementos de alta resistência térmica em suas composições, através de resultados importantes como atraso térmico elevado, e, ao mesmo tempo, teve o menor valor de temperatura de globo negro no interior dos modelos, em relação aos forros compostos de EVA + resíduos. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia de Agrícola pt_BR
dc.title Desempenho e eficiência térmica de placas tipo sanduíche e eva + resíduos como forro de cobertura. pt_BR
dc.description.abstract The EVA polymers’ residue (Ethylene Vinyl Acetate) has suitable characteristics for recycling purposes, transforming them into lightweight aggregates, which may bring benefits to the constructed environment, such, for example, its exploitation in form of thermal insulator for liners, as a blanket. This work was developed with the objective of evaluating the performance and thermal efficiency of liners, using EVA particles + residues as sandwiches plates in coverings of reduced models. The research was held in the experimental area of LaCRA – Laboratory of Rural Constructions and Ambience of Federal University of UFCG (Federal University of Campina Grande, in Campina Grande city, Paraíba State, between the months of July and December 2014. 5 reduced models was constructed, using fiber cement tiles, associated with 4 types of liners, but one without use of liner (control treatment). The tested liners were composed of EVA plates, EVA plates + residues from the pulp and paper industry (PPR), EVA plates + residues from the timber industry (TI) and EVA plates + ceramic residues (CR). The collected variables were “dry and humid bulb temperature” and “relative air humidity”, through thermocouples, and stored in the Campbell CR1000 data acquisition system; for the external environment variables, bulb temperature (dry and humid) and air velocity were measured. The thermal properties of liners were analyzed by calculating thermal resistance, thermal transmittance, thermal capacity, thermal delay and solar factor. This study has proved the good thermal performance of the liner composed solely of EVA as thermal insulator, which showed high thermal resistance elements in its compositions, through important results as increased thermal delay, and, at the same time, had the lowest value of black globe temperature inside the models, in relation to liners composed of EVA + residues. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28125
dc.date.accessioned 2022-11-30T22:51:43Z
dc.date.available 2022-11-30
dc.date.available 2022-11-30T22:51:43Z
dc.type Tese pt_BR
dc.subject Construções rurais e ambiência pt_BR
dc.subject Eficiência Térmica - placa tipo sanduíche pt_BR
dc.subject Instalações zootécnicas pt_BR
dc.subject Cobertura em instalações rurais pt_BR
dc.subject Forros em edificações pt_BR
dc.subject Conforto térmico pt_BR
dc.subject Painéis sanduíches pt_BR
dc.subject Temperatura de bulbo seco pt_BR
dc.subject Temperatura de globo negro pt_BR
dc.subject Modelos reduzidos pt_BR
dc.subject Isolante térmico pt_BR
dc.subject Rural buildings and ambience pt_BR
dc.subject Thermal Efficiency - sandwich plate pt_BR
dc.subject Zootechnical facilities pt_BR
dc.subject Coverage in rural facilities pt_BR
dc.subject Ceilings in buildings pt_BR
dc.subject Thermal comfort pt_BR
dc.subject Sandwich panels pt_BR
dc.subject Dry bulb temperature pt_BR
dc.subject Black globe temperature pt_BR
dc.subject Reduced models pt_BR
dc.subject Thermal insulation pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator COSTA, Raniere Fernandes.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Performance and thermal efficiency of sandwich boards and EVA + waste as cover lining. pt_BR
dc.identifier.citation COSTA, Raniere Fernandes. Desempenho e eficiência térmica de placas tipo sanduíche e eva + resíduos como forro de cobertura. 2015. 120f. (Dissertação de Mestrado) Programa de Pós-Graduação em Engenharia Agrícola, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande - Paraíba - Brasil, 2015. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28125 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta