DSpace/Manakin Repository

Método de cálculo de fasores para linhas de transmissão com compensação em série.

Mostrar registro simples

dc.creator.ID FIGUEIREDO, A. C. C. Q. A. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/5379234567213432 pt_BR
dc.contributor.advisor1 NEVES, Washington Luiz Araujo.
dc.contributor.advisor1ID NEVES, W. L. A. pt_BR
dc.contributor.advisor1ID NEVES, WASHINGTON L.A. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3107104665517286 pt_BR
dc.contributor.advisor2 FERNANDES JÚNIOR, Damásio.
dc.contributor.advisor2ID FERNANDES Jr., D. pt_BR
dc.contributor.advisor2ID FERNANDES JR., DAMÁSIO. pt_BR
dc.contributor.advisor2ID FERNANDES, DAMASIO;JUNIOR. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/3630883713661678 pt_BR
dc.contributor.referee1 SOUZA, Benemar Alencar de.
dc.contributor.referee1ID SOUZA, B. A. pt_BR
dc.contributor.referee1ID DE SOUZA, BENEMAR ALENCAR. pt_BR
dc.contributor.referee1ID DE SOUZA, B. A. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/4987294390789975 pt_BR
dc.contributor.referee2 DANTAS, Karcius Marcelus Colaço.
dc.contributor.referee2ID DANTAS, K. M. C. pt_BR
dc.contributor.referee2ID DANTAS, KARCIUS M. C. pt_BR
dc.contributor.referee2Lattes http://lattes.cnpq.br/1881990103809201 pt_BR
dc.contributor.referee3 VIEIRA JÚNIOR, Jose Carlos de Melo.
dc.contributor.referee3ID VIEIRA JUNIOR, J. C. M. pt_BR
dc.contributor.referee3ID Vieira Jr, Jose Carlos M. pt_BR
dc.contributor.referee3Lattes http://lattes.cnpq.br/1047893003118791 pt_BR
dc.contributor.referee4 COSTA, Flavio Bezerra.
dc.contributor.referee4ID COSTA, F. B. pt_BR
dc.contributor.referee4ID COSTA, FLAVIO B. pt_BR
dc.contributor.referee4Lattes http://lattes.cnpq.br/7510091283933216 pt_BR
dc.description.resumo Apresenta-se aqui a proposição de um método de cálculo de fasores para ser utilizado na proteção de distância de linhas de transmissão com compensação capacitiva em série. O método proposto consiste no uso de cascatas de filtros digitais lineares não recursivos e invariantes no tempo. Os filtros utilizados foram projetados para eliminar componentes oscilatórias com decaimento exponencial. Esse tipo de componente está presente em linhas de transmissão com o tipo de compensação mencionado e convém se desvencilhar de sua influência pois ela pode provocar classificações indevidas do curto-circuito como pertencente à zona de proteção. Outros métodos de cálculos de fasores existentes na literatura voltados para uso em linhas de transmissão com compensação capacitiva em série utilizam métodos não lineares e o uso de filtros lineares e invariantes no tempo, como proposto nesta tese, é vantajoso porque facilita a análise do método. O filtro proposto nesta tese é estável, apresenta em exemplos mostrados uma resposta em frequência compatível e possui um tempo de atuação na proteção de distância compatível. Foram mostrados exemplos em que a trajetória de impedância do método proposto apresenta uma espiral reduzida ou não apresenta espiral em torno do valor final, enquanto outros métodos encontrados na literatura apresentam uma espiral acentuada para casos de curto- circuito na barra remota. Constatou-se que o método proposto tem um melhor desempenho na determinação se o curto-circuito pertence à primeira zona de proteção nas situações em que existe tendência a haver uma trajetória de impedância expansiva em torno do valor final. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica pt_BR
dc.title Método de cálculo de fasores para linhas de transmissão com compensação em série. pt_BR
dc.date.issued 2022-09-15
dc.description.abstract It is presented here the proposition of a phasor calculation method to be used in distance protection of capacitive series compensated transmission lines. The proposed method consists in the usage of cascades of non-recursive time invariant linear digital filters. The used filters were projected to eliminate oscillatory components with exponential decays. This kind of component is present in signals from transmission lines with the mentioned sort of compensation, and it is convenient to avoid its influence because it can cause wrong fault classifications as being in the protection zone. Other methods of phasor calculation existent in the literature presented as suitable to series compensated transmission lines are based in non- linear methods and the usage of time invariant linear filters, as proposed in this thesis, is an advantage because the analysis of the method is easier. The filter proposed in this thesis is stable, it has in some shown examples a compatible frequency response, and it has a compatible actuation time of distance protection. In some examples shown, the proposed method corresponds to an impedance trajectory with a reduced or absent spiral around the final value, when others methods proposed in the literature generate an expansive swirling trajectory. These examples are for short-circuits in the remote bus. It was noted that the proposed method has a better performance in determining whether the short-circuit belongs to the first protection zone in situations prone to a spiraling impedance trajectory around the final impedance calculated value. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28282
dc.date.accessioned 2022-12-12T17:50:53Z
dc.date.available 2022-12-12
dc.date.available 2022-12-12T17:50:53Z
dc.type Tese pt_BR
dc.subject Processamento da energia pt_BR
dc.subject Compensação capacitiva em série pt_BR
dc.subject Linhas de transmissão pt_BR
dc.subject Proteção de distância pt_BR
dc.subject Relés digitais pt_BR
dc.subject Energy processing pt_BR
dc.subject Transmission lines pt_BR
dc.subject Digital relays pt_BR
dc.subject Capacitive compensation in series pt_BR
dc.subject Distance protection pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator FIGUEIREDO, Arthur Cesar Claudino Queiroga de Abrantes.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Phasor calculation method for transmission lines with series compensation. pt_BR
dc.title.alternative Método de cálculo fasorial para líneas de transmisión compensadas en serie.
dc.identifier.citation FIGUEIREDO, Arthur Cesar Claudino Queiroga de Abrantes. Método de cálculo de fasores para linhas de transmissão com compensação em série. 2022. 131fl. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande - Paraíba - Brasil, 2022. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/28282 pt_BR
dc.description.resumen Se presenta aquí la proposición de un método de cálculo fasorial para ser utilizado en la Protección de distancia de líneas de transmisión con compensación capacitiva en serie. El método propuesto consiste en el uso de cascadas de filtros digitales lineales no recursivos e invariantes en el tiempo. Los filtros utilizados fueron diseñados para eliminar componentes oscilatorios con Decrecimiento exponencial. Este tipo de componente está presente en líneas de transmisión con el tipo de compensación mencionado y es recomendable deshacerse de su influencia ya que puede provocar una clasificación incorrecta del cortocircuito como perteneciente a la zona de protección. Otros métodos de cálculo fasorial existentes en la literatura destinados al uso en líneas eléctricas transmisión con compensación capacitiva en serie utilizan métodos no lineales y el uso de filtros lineales e invariantes en el tiempo, como se propone en esta tesis, es ventajoso porque facilita la análisis de métodos. El filtro propuesto en esta tesis es estable, se presenta en ejemplos mostrados una respuesta de frecuencia compatible y tiene un tiempo de actuación de protección de distancia compatible. Se mostraron ejemplos en los que la trayectoria de impedancia del método propuesto muestra una espiral reducida o ninguna espiral alrededor del valor final, mientras que otros encontrados en la literatura presentan una espiral acentuada para los casos de cortocircuito en el bus remoto. Se encontró que el método propuesto tiene una mejor rendimiento para determinar si el cortocircuito pertenece a la primera zona de protección en situaciones en las que tiende a haber una ruta de impedancia expansiva alrededor del valor final.


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta