DSpace/Manakin Repository

Biometria fetal pela ultrassonografia da 24a à 38a semanas de gestação no Nordeste do Brasil.

Mostrar registro simples

dc.creator.ID VASCONCELOS, L. M. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/1872643818586326 pt_BR
dc.contributor.advisor1 COSTA, Antônio Gadelha da.
dc.contributor.advisor1ID GADELHA-COSTA, A. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0388242608904648 pt_BR
dc.contributor.advisor-co1 GADELHA, Patricia Spara.
dc.contributor.advisor-co1ID GADELHA, P. S. pt_BR
dc.contributor.advisor-co1Lattes http://lattes.cnpq.br/1196217025300715 pt_BR
dc.contributor.advisor-co2 SOUSA, Jorge Alves de.
dc.contributor.advisor-co2ID SOUSA, J. A. pt_BR
dc.contributor.advisor-co2Lattes http://lattes.cnpq.br/0226886239142027 pt_BR
dc.contributor.referee1 SANTOS, Mayra Pereira dos.
dc.contributor.referee1ID SANTOS, Mayra Pereira dos. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/8723666472401082 pt_BR
dc.contributor.referee2 CATÃO, Carmem Dolores de Sá.
dc.contributor.referee2ID CATÃO, CARMEM DOLORES DE SÁ. pt_BR
dc.contributor.referee2Lattes http://lattes.cnpq.br/7173639352326441 pt_BR
dc.description.resumo O objetivo deste trabalho foi construir curvas da biometria fetal pela ultrassonografia na idade gestacional de 24 a 38 semanas de gestação na região Nordeste do Brasil, considerando que estes parâmetros podem variar a depender da população estudada, e são utilizados para cálculo de peso fetal e avaliação de crescimento intrauterino. Neste estudo, foram utilizados o diâmetro bi parietal (DBP), diâmetro occipital - frontal (DOF), circunferência cefálica (CC), diâmetro Antero-posterior do abdome (DAP), diâmetro transverso do abdome (DTA), circunferência abdominal (CA) e o comprimento do fêmur (CF), em estudo observacional, transversal, com análise retrospectiva, por meio da ultrassonografia bidimensional. Realizou-se análise estatística dos dados através de análise de regressão e equações foram elaboradas por método dos mínimos quadrados, com representação dos resultados através de gráficos e tabelas baseados em percentuais. Concluímos que, comparando com dados da literatura, houve melhor correlação entre valores de DBP e CF, porém maior discrepância quando analisados CC e CA. Dessa forma, nossos dados são importantes para a avaliação do crescimento fetal em pacientes do nordeste do Brasil. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências Biológicas e da Saúde - CCBS pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Medicina pt_BR
dc.title Biometria fetal pela ultrassonografia da 24a à 38a semanas de gestação no Nordeste do Brasil. pt_BR
dc.date.issued 2019-11-19
dc.description.abstract This study aimed to elaborate fetal biometry curves, by ultrasonography, comprising 24 to 38 weeks of gestation in Northeast Brazil, considering parameters may vary depending on the population being studied, and are used to calculate fetal weight and evaluate fetal intrauterine growth. In this study, we analyzed biparietal diameter (DBP), occipitofrontal diameter (DOF), head circumference (CC), abdominal anteroposterior diameter (DAP), abdominal transverse diameter (DTA), abdominal circumference (CA) and fêmur length (CF), in a cross-sectional, retrospective study, using bidimensional sonographic imaging. We performed analysis of the data, with representation of the results through graphs and tables based on percentiles. We created gestational age graphs through regression analysis and appropriate equations through minimum squares method for percentiles 5, 50 and 95 (p<0.05) We concluded that, comparing with literature data, there was a better correlation between DBP and CF values, but greater discrepancy between CA and CC. Our data is importante to create local references, and compare with literature references. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/30589
dc.date.accessioned 2023-07-07T14:47:52Z
dc.date.available 2023-07-07
dc.date.available 2023-07-07T14:47:52Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Ultrassonografia pt_BR
dc.subject Biometria fetal pt_BR
dc.subject Idade gestacional pt_BR
dc.subject Crescimento intrauterino pt_BR
dc.subject Ultrasound pt_BR
dc.subject Fetal biometry pt_BR
dc.subject Gestational age pt_BR
dc.subject Intrauterine growth pt_BR
dc.subject Ultrasonido pt_BR
dc.subject Edad gestacional pt_BR
dc.subject Crecimiento intrauterino pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator VASCONCELOS, Lucas Marinho.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Fetal biometry by ultrasonography from the 24th to the 38th gestational week in Northeastern Brazil. pt_BR
dc.title.alternative Biometría fetal por ultrasonografía de la semana 24 a la 38 de gestación en el Noreste de Brasil. pt_BR
dc.identifier.citation VASCONCELOS, Lucas Marinho. Biometria fetal pela ultrassonografia da 24a à 38a semanas de gestação no Nordeste do Brasil. 2019. 49 fl. (Trabalho de Conclusão de Curso – Monografia), Curso de Bacharelado em Medicina, Centro de Ciências Biológicas e da Saúde, Universidade Federal de Campina Grande – Paraíba – Brasil, 2019. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/30589 pt_BR
dc.description.resumen El objetivo de este trabajo fue construir curvas de biometría fetal por ultrasonido a la edad gestacional de 24 a 38 semanas de gestación en la región Nordeste de Brasil, considerando que estos parámetros pueden variar dependiendo de la población estudiada, y se utilizan para calcular el peso fetal y evaluar el crecimiento intrauterino. En esto estudio, el diámetro biparietal (BPD), diámetro occipito-frontal (DOF), perímetro cefálico (CC), diámetro anteroposterior del abdomen (DAP), diámetro transversus abdominis (DTA), circunferencia abdominal (AC) y longitud del fémur (FC), en un estudio observacional, transversal, con análisis retrospectivo, a través de la ultrasonido bidimensional. El análisis estadístico de los datos se llevó a cabo a través de El análisis de regresión y las ecuaciones se prepararon utilizando el método de mínimos cuadrados, con representación de los resultados a través de gráficos y tablas basados ​​en percentiles. Concluimos que, comparando con los datos de la literatura, hubo una mejor correlación entre Valores de PAD y CF, pero mayor discrepancia al analizar CC y AC. Por lo tanto, nuestros datos son importantes para la evaluación del crecimiento fetal. en pacientes del noreste de Brasil. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta