As manifestações patológicas presentes nas edificações remetem a um conjunto de
deficiências que ocorrem durante o processo construtivo da obra ou no decorrer do
tempo, como também da ausência de projetos. Desse modo, a patologia é a ciências
que estudar a origem, causa e mecanismo das manifestações patológica, com a
finalidade de garantir durabilidade e desempenho das construções. Assim, diante das
anomalias constatadas, deve-se realizar as intervenções corretivas acercas da origem
pela qual os problemas se desenvolveram. Nesse contexto, este trabalho tem como
objetivo identificar as manifestações patológicas constatadas na edificação unifamiliar
localizada na cidade de Pombal – PB, para assim, mediante os diagnósticos propor
orientações técnica de correção e reparos dos problemas. A metodologia adotada
para o desenvolvimento desse trabalho consiste na realização de uma vistoria,
associada ao método da norma de inspeção predial NBR 16747/2020 (ABNT, 2020)
e da matriz GUT (Gravidade, Urgência e Tendência). Diante dos resultados, pôde-se
categorizar as manifestações patológicas, no qual foram constatados problemas
como, fissuras, carbonatação, corrosão das armaduras, problemas relacionados a
umidade e eflorescência, problemas no revestimento argamassado e cerâmico,
problemas nas instalações hidráulicas e sanitárias, problemas nas instalações
elétricas, problemas com esquadrias e problemas na execução no piso do box dos
banheiros, e como isso propor medidas de prevenção e correção. A maiorias dessas
manifestações patológicas são provenientes da falha nas etapas de concepção e
execução da construção, que são 53%, ou seja, anomalia endógenas. Com relação
ao grau de risco (prioridade 1, prioridade 2 e prioridade 3), foi constatado, que, 20%
das anomalias apresenta prioridade 1 (nível crítico), 24% são prioridade 2 (nível
médio) e 56% prioridade 3 (nível mínimo). Assim, diante da análise efetuada,
possibilitou propor tratamentos para recuperação dos sistemas construtivos. Portanto,
com base na inspeção realizada, a edificação necessita de manutenção imediata dos
sistemas construtivos, aliado as vistorias periódicas, fiscalizada por profissionais
qualificado, garantido, assim, habitabilidade e segurança aos usuários. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Ciências e Tecnologia Agroalimentar - CCTA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Civil. |
pt_BR |
dc.title |
Inspeção predial: um estudo de caso em uma edificação unifamiliar localizada na cidade de Pombal – PB. |
pt_BR |
dc.date.issued |
2023-07-12 |
|
dc.description.abstract |
The pathological manifestations present in buildings refer to a set of
deficiencies that occur during the construction process of the work or during the
time, as well as the absence of projects. Thus, pathology is the science
to study the origin, cause and mechanism of the pathological manifestations, with the
purpose of ensuring durability and performance of constructions. So, in the face of
anomalies found, corrective interventions must be carried out regarding the origin
which the problems developed. In this context, this work aims to
objective to identify the pathological manifestations found in the single-family building
located in the city of Pombal - PB, so, through the proposed diagnoses
technical guidance for correcting and repairing problems. The adopted methodology
for the development of this work consists of carrying out an inspection,
associated with the method of the building inspection standard NBR 16747/2020 (ABNT, 2020)
and the GUT matrix (Severity, Urgency and Trend). In view of the results, it was possible to
categorize the pathological manifestations, in which problems were found
such as cracks, carbonation, reinforcement corrosion, problems related to
humidity and efflorescence, problems with mortar and ceramic coating,
problems in plumbing and sanitary installations, problems in installations
electrical, problems with frames and problems in the execution on the floor of the box of
bathrooms, and as a result propose preventive and corrective measures. most of these
pathological manifestations come from failure in the stages of conception and
construction execution, which are 53%, ie endogenous anomaly. regarding
to the degree of risk (priority 1, priority 2 and priority 3), it was found that 20%
of the anomalies have priority 1 (critical level), 24% are priority 2 (level
medium) and 56% priority 3 (minimum level). Thus, based on the analysis carried out,
made it possible to propose treatments for the recovery of constructive systems. Therefore,
based on the inspection carried out, the building needs immediate maintenance of the
construction systems, combined with periodic inspections, supervised by professionals
qualified, thus guaranteeing habitability and safety for users. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/31132 |
|
dc.date.accessioned |
2023-08-01T13:36:20Z |
|
dc.date.available |
2023-08-01 |
|
dc.date.available |
2023-08-01T13:36:20Z |
|
dc.type |
Trabalho de Conclusão de Curso |
pt_BR |
dc.subject |
Manifestações patológicas |
pt_BR |
dc.subject |
Pathological manifestations |
pt_BR |
dc.subject |
Matriz GUT |
pt_BR |
dc.subject |
GUT matrix |
pt_BR |
dc.subject |
Ensaios não destrutivos |
pt_BR |
dc.subject |
Non-destructive testing |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
SILVA, Anderson Ferreira da. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Building inspection: a case study in a single-family building located in the city of Pombal - PB. |
pt_BR |
dc.identifier.citation |
SILVA, Anderson Ferreira da. Inspeção predial: um estudo de caso em uma edificação unifamiliar localizada na cidade de Pombal – PB. 2023. 96 f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2023. |