DSpace/Manakin Repository

Estudo da fluidodinâmica do processo de separação partícula sólida/água via hidrociclone filtrante: modelagem e simulação.

Mostrar registro simples

dc.creator.ID CAVALCANTE, D. C. M. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/3791681900826752 pt_BR
dc.contributor.advisor1 FARIAS NETO, Severino Rodrigues de.
dc.contributor.advisor1ID FARIAS NETO, S. R. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/5029314237107938 pt_BR
dc.contributor.referee1 LIMA, Antonio Gilson Barbosa de.
dc.contributor.referee2 SOUZA, Josedite Saraiva de.
dc.contributor.referee3 FARIAS, Fabiana Pimentel Macêdo.
dc.contributor.referee4 CAVALCANTI, Wilma Sales.
dc.description.resumo Os hidrociclones convencionais são equipamentos versáteis, devido a elevada capacidade de processamento, baixo custo de manutenção. Vários são os estudos que visam alterar a estrutura típica do hidrociclone convencional de modo alterar seu desempenho e objetivo. Assim surgiu os hidrociclones filtrantes no qual se diferencia do hidrociclone convencional pela substituição da parede cônica ou cilíndrica por uma membrana porosa. Durante o funcionamento desse separador, além das correntes tradicionalmente observadas (alimentação, underflow e overflow), há uma corrente líquida proveniente do processo de filtração, normalmente denominado filtrado. O presente trabalho propõe estudar hidrociclones filtrantes baseados no trabalho de Façanha (2012), a partir do estudo numérico do processo de separação água/partícula sólida realizado com auxílio do “software” comercial ANSYS CFX® Release 15.0. O modelo matemático usado considera escoamento tridimensional, turbulento, estacionário, baseado na abordagem Euleriana-Euleriana e modelo de turbulência SST “Shear Stress Transport”. Foram avaliados estudos da dinâmica do escoamento, Efeito da porosidade, efeito da permeabilidade e efeito da matriz porosa. Os resultados demonstram que a vazão do filtrado é menor em relação as outras saídas, altera o escoamento no interior do hidrociclone filtrante tanto em relação a porosidade, permeabilidade e efeito da posição do meio filtrante. O aumento da porosidade e permeabilidade alterou a distribuição de pressão, razão do líquido e eficiência total no interior do hidrociclo cilíndrico filtrante. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA DE PROCESSOS pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Ciências pt_BR
dc.title Estudo da fluidodinâmica do processo de separação partícula sólida/água via hidrociclone filtrante: modelagem e simulação. pt_BR
dc.date.issued 2017-08-24
dc.description.abstract Conventional hydrocyclones are versatile equipment due to high processing capacity and low maintenance costs. Several studies are aimed at changing the typical structure of conventional hydrocyclone in order to alter its performance and purpose. In this way the hydrocyclones filtering in which it differs from the conventional hydrocyclone by the replacement of the conical or cylindrical wall by a porous membrane. During the operation of this separator, in addition to the traditionally observed currents (feed, underflow and overflow), there is a liquid stream coming from the filtration process, usually called filtrate. The present work proposes to study filtering hydrocyclones based on the work of Façanha (2012), based on the numerical study of the water / solid particle separation process performed with the commercial software ANSYS CFX® Release 15.0. The mathematical model used considers three-dimensional, turbulent, stationary flow, based on the Eulerian-Eulerian approach and SST turbulence model "Shear Stress Transport". Studies of flow dynamics, porosity effect, permeability effect and porous matrix effect were evaluated. The results show that the flow rate of the filtrate is lower in relation to the other outlets, it changes the flow inside the filter hydrocyclone in relation to the porosity, permeability and effect of the position of the filter medium. The increase in porosity and permeability altered the pressure distribution, liquid ratio and total efficiency inside the filter cylindrical hydrocyclones. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/314
dc.date.accessioned 2018-03-23T18:34:30Z
dc.date.available 2018-03-23
dc.date.available 2018-03-23T18:34:30Z
dc.type Tese pt_BR
dc.subject Fluidodinâmica pt_BR
dc.subject Hidrociclones pt_BR
dc.subject Membrana Porosa pt_BR
dc.subject ANSYS CFX pt_BR
dc.subject Hydrocyclones pt_BR
dc.subject Fluid Dynamics pt_BR
dc.subject Porous Membrane pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator CAVALCANTE, Daniel Cesar de Macedo.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.description.sponsorship Capes pt_BR
dc.identifier.citation CAVALCANTE, D. C de M. Estudo da fluidodinâmica do processo de separação partícula sólida/água via hidrociclone filtrante: modelagem e simulação. 2017. 113 f. Tese (Doutorado em Engenharia de Processos) – Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/314 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta