Dépôt DSpace/Manakin

Estudo de parâmetros físico-químicos e bacteriológicos em piscinas dos municípios de Campina Grande e Boqueirão - Paraíba.

Afficher la notice abrégée

dc.creator.ID URTIGA, R. F. pt_BR
dc.contributor.advisor1 CEBALLOS, Beatriz Susana Ovruski de.
dc.contributor.advisor1ID CEBALLOS, B. S. O pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/9321950498637802 pt_BR
dc.contributor.referee1 MENDONÇA, Sérgio Rolim.
dc.contributor.referee2 PRASAD, Shiva.
dc.contributor.referee3 OLIVEIRA, Rui de.
dc.description.resumo A presente pesquisa teve como objetivo o estudo de parâmetros físico-químicos e bacteriológicos em piscinas públicas e privadas, para adultos e para crianças dos municípios de Campina Grande e Boqueirão, com afinalidade de se analisar os fatores que contribuem para a deterioração de suas águas e sugerir critérios para aplicação local de padrões sanitários. Foi também avaliada uma técnica de coleta de amostras para análises bacteriológicas. Este estudo foi realizado no período de julho a dezembro de 1987. As coletas foram feitas aos domingos e no horário de 11 às 15:30 horas, por ser o de maior frequência de usuários. Os parâmetros físico-químicos pesquisados foram: temperatura, pH, transparência, turbidez, visibilidade, cloro residual livre e combinado, cloretos, dureza e alcalinidade total. Os parâmetros bacteriológicos foram, coliformes fecais (CF), estreptococos fecais (EF), Staphyloccus spp (ST) com identificação de S. aureus, Pseudonomas aeruginosa (PA) e bactérias facultativas heterótrofas mesófilas (BFHM).Todas as piscinas dos clubes estudados apresentaram condições sanitárias deficientes, caracterizadas pela ausência frequente de cloro residual livre e combinado (quando presentes, suas concentrações eram inferior e são mínimo recomendado de 0,2-0,4 ppm), valores elevados de turbidez, pH, dureza, cloretos e alcalinidade total, ausência de recirculação e filtração nas horas de uso em 50% das piscinas, números elevados e frequência alta de isolamento de todos os indicadores bacteriológicos. As condições mais deficientes foram observadas nas piscinas infantis. Na maioria das piscinas houve associação entre aumento do número de banhistas e aumento do número de bactérias indicadoras, sendo que as piscinas sem recirculação e filtração apresentaram associação mais significativa. Foi concluído que a faixa padrão de turbidez de 1,0 a 5,0 NTU, utilizada para agua potável não pode ser aplicada em piscinas já que todas as amostras com turbidez superior a 3,0 NTU corresponderam a transparência negativa, fora dos padrões. Uma turbidez máxima de 1,5-2,0 NTU poderia ser mais adequada, visto que aproximadamente 60% das determinações; com esta turbidez corresponderam a transparência média. Foi observado que o valor padrão de 250 mg Cl- /l, não poderia ser aplicado em nossa região, já que a água que alimenta as piscinas contêm uma concentração média de 311 mg Cl-/l. Dentre as bactérias isoladas, foi observado que: os estafilococos, especialmente S. aureus, são bons indicadores da eficiência da desinfecção devido a sua alta resistência ao cloro. Os estreptococos fecais se mostraram mais resistente são condições ambientais que os coliformes fecais, e portanto são importantes indicadores de contaminação fecal, especialmente quando os coliformes fecais estão ausentes. Os resultados sugerem que as principais causas da deterioração da agua foram as deficiências do tratamento físico-químico, que favoreceram a presença das bactérias, introduzidas principalmente, pelos banhistas. Nas piscinas públicas foram verificadas acentuadas alterações bacteriológicas em relação à agua de alimentação. Por exemplo, os coliformes fecais aumentaram 20 vezes numa piscina do tipo encher e esvaziar e 235 vezes numa outra, de circulação continua. Não houve diferenças estatisticamente significativas entre os números de bactérias presentes nas amostras coletadas a 50cm da superfície e na coluna de água até 1,0 metro de profundidade. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil.
dc.title Estudo de parâmetros físico-químicos e bacteriológicos em piscinas dos municípios de Campina Grande e Boqueirão - Paraíba. pt_BR
dc.date.issued 1988-12-22
dc.description.abstract The present research had as objective the study of physico-chemical and bacteriological parameters in public and private swimming pools, for adults and for children of the municipalities of Campina Grande and Boqueirão, in order to analyze the factors that contribute to the deterioration of its waters and to suggest criteria for local application of sanitary standards. A sample collection technique was also evaluated for bacteriological analysis. This study was carried out from July to December 1987. The collections were made on Sundays and from 11:00 to 15:30 hours, since it is the one with the highest frequency of users. The physico-chemical parameters studied were: temperature, pH, transparency, turbidity, visibility, free and combined residual chlorine, chlorides, hardness and total alkalinity. The bacteriological parameters were: fecal coliforms (CF), fecal streptococci (EF), Staphylococcus spp (ST) with identification of S. aureus, Pseudonomas aeruginosa (PA) and heterophthroid facultative bacteria mesophilic (BFHM). (where present, their concentrations were lower and are minimum recommended of 0.2-0.4 ppm), high values ​​of turbidity, pH, hardness, chlorides and total alkalinity , absence of recirculation and filtration in the hours of use in 50% of the swimming pools, high numbers and high frequency of isolation of all the bacteriological indicators. The most deficient conditions were observed in children's pools. In most swimming pools there was an association between an increase in the number of bathers and an increase in the number of indicator bacteria, and the pools without recirculation and filtration had a more significant association. It was concluded that the standard turbidity range of 1.0 to 5.0 NTU used for potable water can not be applied in swimming pools since all turbid samples higher than 3.0 NTU corresponded to negative transparency, out of standards. A maximum turbidity of 1.5-2.0 NTU could be more adequate, since approximately 60% of the determinations; with this turbidity corresponded to the average transparency. It was observed that the standard value of 250 mg Cl- / l could not be applied in our region, since the water supplying the pools contain a mean concentration of 311 mg Cl- / l. Among the isolated bacteria, it was observed that: Staphylococci, especially S. aureus, are good indicators of disinfection efficiency due to their high resistance to chlorine. Fecal streptococci proved to be more resistant to environmental conditions than fecal coliforms, and therefore are important indicators of fecal contamination, especially when faecal coliforms are absent. The results suggest that the main causes of the deterioration of the water were the deficiencies of the physical-chemical treatment, which favored the presence of the bacteria, introduced mainly by the bathers. In the public swimming pools, there were marked bacteriological changes in relation to the feed water. For example, fecal coliforms increased 20-fold in a fill-and-empty pool and 235-fold in a continuous-flow pool. There were no statistically significant differences between the numbers of bacteria present in the samples collected at 50cm from the surface and at the water column up to 1.0 meter deep. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3152
dc.date.accessioned 2019-03-19T14:31:20Z
dc.date.available 2019-03-18
dc.date.available 2019-03-19T14:31:20Z
dc.type Dissertação pt_BR
dc.subject Solos Sódicos - Algodão Herbáceo
dc.subject Algodão Herbáceo - Cultura
dc.subject Recursos Hídricos
dc.subject Engenharia Civil
dc.subject Sodic Soils - Herbaceous Cotton
dc.subject Herbaceous Cotton - Culture
dc.subject Water Resources
dc.subject Civil Engineering
dc.rights Acesso Aberto pt_BR
dc.creator URTIGA, Rui Francisco.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Study of physico-chemical and bacteriological parameters in pools of the municipalities of Campina Grande and Boqueirão-Paraíba. pt_BR
dc.identifier.citation URTIGA, Rui Francisco. Estudo de parâmetros físico-químicos e bacteriológicos em piscinas dos municípios de Campina Grande e Boqueirão- Paraíba. 1988. 179f. Dissertação (Mestrado em Engenharia Civil), Curso de Pós-Graduação em Engenharia Civil, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba – Campus II - Campina Grande - PB - Brasil, 1988. pt_BR


Fichier(s) constituant ce document

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée

Chercher dans le dépôt


Recherche avancée

Parcourir

Mon compte