dc.description.resumo O acompanhamento de profissionais habilitados e qualificados é essencial na construção civil para evitar patologias e garantir a segurança das edificações. No entanto, nas cidades menores, é comum a prática da autoconstrução, o que pode levar a um nível significativo de periculosidade e o surgimento acelerado de patologias. Nesse contexto, a identificação das incoerências normativas é fundamental. Para realizar esse estudo, foi acompanhada a execução de uma residência unifamiliar em Pombal - PB durante o período de quatro meses (outubro de 2022 a fevereiro de 2023). Foram registrados os erros executivos nas peças estruturais e alvenarias, além de identificadas possíveis causas de manifestações patológicas nas falhas construtivas. Também foram realizados ensaios de resistência à compressão do concreto e dos blocos cerâmicos. Os resultados mostraram que o concreto utilizado nas superestruturas não atendeu à resistência mínima exigida pela NBR 6118 (ABNT, 2014). Além disso, houve falhas na execução das fundações, pilares, vigas e lajes, como dimensões inadequadas, aço de diâmetro menor que o requerido e falta de cumprimento de diversas normas relacionadas ao concreto armado. As alvenarias de vedação também apresentaram falhas executivas. Essas inconformidades indicam a existência de erros conceituais e executivos que podem levar ao surgimento de patologias. É importante ressaltar que tais manifestações tendem a se agravar ao longo do tempo e podem provocar o aparecimento de outras patologias associadas. Portanto, é imprescindível identificar essas manifestações o mais rápido possível para facilitar e reduzir os custos do processo de correção. A prática da autoconstrução, sem a observância das normas e o acompanhamento de profissionais adequados, portanto, pode ser responsável por diversas manifestações patológicas, comprometendo a segurança e o conforto dos usuários. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia Agroalimentar - CCTA pt_BR
dc.publisher.initials UFCG pt_BR
dc.title Identificação de incoerências normativas em uma residência autoconstruída no município de Pombal – PB. pt_BR
dc.date.issued 2023-07-12
dc.description.abstract The accompaniment of qualified and qualified professionals is essential in the construction to prevent pathologies and ensure the safety of buildings. At the However, in smaller cities, the practice of self-construction is common, which can lead to a significant level of dangerousness and the accelerated emergence of pathologies. In this context, the identification of normative inconsistencies is fundamental. To carry out this study, the execution of a single-family residence in Pombal - PB during the period of four months (October 2022 to February 2023). Executive errors were recorded in the parts structures and masonry, in addition to identifying possible causes of manifestations pathologies in constructive failures. Resistance tests were also carried out. compression of concrete and ceramic blocks. The results showed that the concrete used in the superstructures did not meet the minimum strength required by NBR 6118 (ABNT, 2014). In addition, there were flaws in the execution of the foundations, pillars, beams and slabs, such as inadequate dimensions, steel with a diameter smaller than the required and lack of compliance with various standards related to concrete armed. The sealing masonry also presented executive failures. These nonconformities indicate the existence of conceptual and executive errors that can lead to pathologies. It is important to emphasize that such manifestations tend to get worse over time and may cause the appearance of other associated pathologies. Therefore, it is essential to identify these manifestations as soon as possible to facilitate and reduce the costs of the correction process. A practice of self-construction, without observing the norms and monitoring appropriate professionals, therefore, may be responsible for several manifestations pathological conditions, compromising the safety and comfort of users. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/31607
dc.date.accessioned 2023-08-24T17:11:58Z
dc.date.available 2023-08-24
dc.date.available 2023-08-24T17:11:58Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Construção civil pt_BR
dc.subject Construction pt_BR
dc.subject Autoconstrução pt_BR
dc.subject Self-construction pt_BR
dc.subject Patologia pt_BR
dc.subject Pathology pt_BR
dc.subject Erro executivo pt_BR
dc.subject Error executive pt_BR
dc.subject Edificação unifamiliar pt_BR
dc.subject Single-family building pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator WOLMER, Wanzley Rafael De Sousa.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Identification of normative inconsistencies in a self-built residence in the municipality of Pombal - PB. pt_BR
dc.identifier.citation WOLMER, Wanzley Rafael De Sousa. Identificação de incoerências normativas em uma residência autoconstruída no município de Pombal – PB. 2023. 72 f. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) - Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande, Pombal, Paraíba, Brasil, 2023. pt_BR