DSpace/Manakin Repository

Sensores termo-resistivos e ultrassônicos na medição de fluxo respiratório com a técnica de oscilações forçadas.

Mostrar registro simples

dc.creator.ID ARAÚJO, G. A. L. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/8261564685433904 pt_BR
dc.contributor.advisor1 FREIRE, Raimundo Carlos Silvério.
dc.contributor.advisor1ID FREIRE, R. C. S. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4016576596215504 pt_BR
dc.contributor.advisor2 CATUNDA, Sebastian Yuri Cavalcanti.
dc.contributor.advisor2ID CATUNDA, S. Y. C. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/0873496251879638 pt_BR
dc.contributor.referee1 DÓI, Ioshiaki.
dc.contributor.referee2 BARROS, Allan Kardec Dualibe.
dc.contributor.referee3 SILVA, João Bosco de Aquino.
dc.contributor.referee4 LUCIANO, Benedito Antonio.
dc.description.resumo A técnica de oscilações forçadas é um método não invasivo de avaliação da mecânica pulmonar. Ela é usada para determinar a impedância do sistema respiratório que é calculada a partir de sinais de pressão e fluxo medidos próximos à boca do paciente. No sistema convencional estes sinais são induzidos a partir de sinais senoidais de pressão impostos por meio de um alto-falante e o transdutor de fluxo é um pneumotacômetro. Este equipamento mede a diferença de pressão entre dois pontos de um tubo que tem uma resistência mecânica interna, constituída de vários tubos capilares sobrepostos ou finas malhas metálicas. A tendência é que o pneumotacômetro seja bloqueado por saliva e condensação durante um uso prolongado, devido às partículas expelidas pelo paciente no processo respiratório. Isto aumenta a resistência efetiva do sensor de fluxo e conduz a erros. Visando encontrar métodos alternativos para a medição de fluxo respiratório com a técnica de oscilações forçadas, são utilizados outros tipos de sensores, tais como sensores termo-resistivos de fio de platina e sensores ultra-sônicos. São mostrados resultados experimentais da medição do fluxo respiratório com esses sensores e comparados com os obtidos com um pneumotacômetro. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica.
dc.title Sensores termo-resistivos e ultrassônicos na medição de fluxo respiratório com a técnica de oscilações forçadas. pt_BR
dc.date.issued 2007-05
dc.description.abstract The forced oscillations technique is a non invasive method to investigate lung mechanics. It is used to determine the impedance of the respiratory system that is derived from the pressure and flow signals recorded at the mouth of the patient. In the conventional setup these signals are induced starting from sinusoidal pressure signals imposed by means of a loudspeaker, and the flow transducer is a pneumotachometer. This equipment measures the pressure difference between two points on a tube with an inner mechanical resistance element consisting of a bundle of capillary tubes or a wire mash screen. The pneumotachometer tendency is to become clogged with mucous and condensations during prolonged use, due to the particles expelled by the patient in the respiratory process. This increases the effective resistance of the flow head and leads to errors. In order to find alternative methods for the measurement of the respiratory flow with the forced oscillations technique, other kinds of sensor are used, such as platinum wire termoresistive sensors and ultrasonic sensors. Experimental results of the respiratory flow measured with these sensors are showed and compared with the results obtained by a pneumotachometer. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3231
dc.date.accessioned 2019-03-25T17:11:38Z
dc.date.available 2019-03-25
dc.date.available 2019-03-25T17:11:38Z
dc.type Tese pt_BR
dc.subject Medição de Fluxo Respiratório
dc.subject Anemómetro a Fio Aquecido
dc.subject Anemómetro Ultrassônico
dc.subject Técnica de Oscilações Forçadas
dc.subject Measurement of Respiratory Flow
dc.subject Heated Wire Anemometer
dc.subject Ultrasonic Anemometer
dc.subject Technique of Forced Oscillations
dc.rights Acesso Aberto pt_BR
dc.creator ARAÚJO, Guilherme Augusto Limeira.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Thermo-resistive and ultrasonic sensors in the measurement of respiratory flow with the technique of forced oscillations. pt_BR
dc.identifier.citation ARAÚJO, Guilherme Augusto Lima. Sensores termo-resistivos e ultrassônicos na medição de fluxo respiratório com a técnica de oscilações forçadas. 2007. 113 f. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2007. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta