Estimação de fasores baseada na transformada wavelet para uso na proteção de distância de linhas de transmissão.

Mostrar registro simples

dc.creator.ID SILVA, K. M. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/8795500242651581 pt_BR
dc.contributor.advisor1 SOUZA, Benemar Alencar de.
dc.contributor.advisor1ID SOUZA, B. A. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4987294390789975 pt_BR
dc.contributor.advisor2 NEVES, Washington Luiz Araújo.
dc.contributor.advisor2ID NEVES, W. L. A. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/3107104665517286 pt_BR
dc.contributor.referee1 COURY, Denis Vinicius.
dc.contributor.referee2 SILVEIRA, Paulo Márcio da.
dc.contributor.referee3 LEITÃO, José Júlio de Almeida Lins.
dc.contributor.referee4 MOTA, Wellington Santos.
dc.description.resumo Um novo algoritmo de estimação de fasores é proposto nesta tese, o qual utiliza filtros ortogonais de um ciclo em conjunto com um novo filtro mímico adaptativo. Os filtros ortogonais são projetados off-line por uma técnica inédita, a qual reúne as características de filtragem da transformada wavelet discreta redundante e do algoritmo dos mínimos quadrados. O filtro mímico adaptativo proposto é obtido, basicamente, de uma estratégia de ajuste adaptativo dos parâmetros do tradicional filtro mímico digital, a fim de eliminar a influência da componente DC de decaimento exponencial na estimação dos fasores. As respostas em frequência e no tempo do algoritmo proposto foram comparadas com as dos tradicionais algoritmos dos mínimos quadrados e de Fourier de um e de meio ciclo, que foram combinados com o tradicional filtro mímico digital. Para tanto, foram utilizados sinais referentes à faltas reais e simuladas em programas do tipo EMTP e em um simulador digital em tempo real de sistemas elétricos de potência. Os resultados obtidos indicam que o algoritmo proposto é, na maioria dos casos, mais imune à influência da componente DC de decaimento exponencial do que os algoritmos tradicionais. Ele também não é afetado pelas harmônicas presentes nos sinais, possui resposta transitória com menos oscilações e, em algumas situações, pode ser mais rápido do que os algoritmos tradicionais de um ciclo. Estas características, bem como sua implementação em tempo real, indicam a viabilidade da utilização deste algoritmo em relés de distância em escala comercial. Como contribuição adicional, ressalta-se que, não obstante o novo filtro mímico adaptativo tenha sido avaliado em conjunto com os filtros ortogonais projetados com a técnica proposta, ele pode ser empregado em conjunto com outros, a exemplo dos filtros de Fourier de um ciclo, a fim de eliminar a influência da componente DC de decaimento exponencial na estimação de fasores com estes filtros. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica.
dc.title Estimação de fasores baseada na transformada wavelet para uso na proteção de distância de linhas de transmissão. pt_BR
dc.date.issued 2009-04-17
dc.description.abstract A novel phasor estimation algorithm is proposed in this thesis, which uses full cycle orthogonal filters combined with a an adaptive digital mimic filter. The orthogonal filters are designed offline in advance using an innovative filter design technique, which takes into account the filtering characteristics of the maximum overlap discrete wavelet transform and the ones of the least error square algorithm. The proposed adaptive digital mimic filter is obtained using an adaptive strategy to compute the traditional digital mimic filter parameters, in order to eliminate the decaying DC component effect on phasor estimation. The time and frequency responses of the proposed algorithm are compared to the ones of the traditional least error square and the full cycle and half cycle Fourier algorithms, which are combined with the traditional digital mimic filter. In order to do that, actual fault data are used, as well as simulated fault data using an electromagnetic transients program and a power system real time digital simulator. The obtained results reveal that the proposed algorithm better rejects the decaying DC component in the majority of cases. In addition to that, the proposed algorithm rejects all harmonics, presents better transient responses and may be faster than the traditional full cycle algorithms in some cases. These characteristics and the real tim implementation of the proposed algorithm reveal the feasibility of its application in manufactured protective relays. As a byproduct, despite the adaptive digital mimic filter has been evaluated in conjunction with the designed orthogonal filters, another ones may be used too, such as the full cycle Fourier filters, in order to provide better decaying DC rejection in phasor estimation using these filters. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3267
dc.date.accessioned 2019-03-27T15:35:54Z
dc.date.available 2019-03-27
dc.date.available 2019-03-27T15:35:54Z
dc.type Tese pt_BR
dc.subject Proteção de Distância.
dc.subject Linhas de Transmissão.
dc.subject Estimação de Fasores.
dc.subject Filtro Mímico Adaptativo.
dc.subject Transformada Wavelet Discreta Redundante.
dc.subject Distance Protection.
dc.subject Transmission lines.
dc.subject Estimation of Phasors.
dc.subject Adaptive Mimic Filter.
dc.subject Discrete Wavelet Redundant Transform.
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Kleber Melo e.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Estimation of phasors based on the wavelet transform for use in the protection of transmission line distance. pt_BR
dc.identifier.citation SILVA, Kleber Melo e. Estimação de fasores baseada na transformada wavelet para uso na proteção de distância de linhas de transmissão. 2009. 203f. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2009. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta