DSpace/Manakin Repository

Otimização do processamento da energia em sistemas de bombeamento fotovoltaico e conversão monofásica.

Mostrar registro simples

dc.creator.ID VITORINO, M. A. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/1945886683703701 pt_BR
dc.contributor.advisor1 CORRÊA, Maurício Beltrão de Rossiter.
dc.contributor.advisor1ID CORRÊA, M. B. R. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0041843905239864 pt_BR
dc.contributor.advisor2 BOROYEVICH, Dushan.
dc.contributor.advisor2ID BOROYEVICH, D. pt_BR
dc.contributor.referee1 LIMA, Antonio Marcus Nogueira.
dc.contributor.referee2 ANTUNES, Fernando Luiz Marcelo.
dc.contributor.referee3 JACOBINA, Cursino Brandão.
dc.contributor.referee4 CAVALCANTI, Marcelo Cabral.
dc.description.resumo Considerando as possibilidades para o uso da geração fotovoltaica, e objetivando contribuir para difusão de seu uso, o presente trabalho foi elaborado com base em duas vertentes: (I) otimização do processamento da energia para realização de bombeamento; e (II) otimização do processamento da energia em conversores monofásicos. No sistema de bombeamento a otimização consiste em diminuir as perdas no processamento da energia para se obter um maior volume de água bombeado. Além do estudo em torno do ponto de máxima eficiência de operação da bomba, também é realizada uma análise para maximizar a transferência de potência entre a geração fotovoltaica e a bomba centrífuga reduzindo as perdas em cada estágio do processamento da energia. Na outra vertente deste trabalho, a otimização visa reduzir a potência monofásica oscilatória que se propaga ao longo de um sistema de conversão de energia, onde esta potência oscilatória pode ser indesejável em sinais que necessitam possuir suas formas de ondas contínuas, por provocar vários problemas no conversor monofásico, tais como: dificuldade no seu controle; aumento no volume e diminui»c~ao de vida útil dos elementos que o compõem; e diminuição da vida útil dos dispositivos ligados ao seu lado CC e/ou CA. Neste trabalho é feito o estudo aprofundado nos conversores monofásicos, tanto o VSC quanto o CSC, operando nas trâs formas de conversão de energia aqui abordadas: conversão CA-CC, CC-CA e CA-CC-CA. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica.
dc.title Otimização do processamento da energia em sistemas de bombeamento fotovoltaico e conversão monofásica. pt_BR
dc.date.issued 2012-08-31
dc.description.abstract Considering the possibilities for using of photovoltaic generation and aiming to contribute with its propagation, this work was elaborated based in two parts: (I) optimization of the power processing to realize water pumping; and (II) optimization of the power processing in single-phase converters. In the photovoltaic pumping system the optimization consists in reducing the losses in the power processing to reach a bigger volume of water pumped. Besides the study of the operating maximum efficiency point of the pump, it is also realized an analysis to maximize the power transfer between the photovoltaic generation and the centrifugal pump to reduce the losses in each stage of the power processing. In the other part of this work, the optimization aims to mitigate the oscillating single-phase power that propagates through a power conversion system, where that oscillating power may be undesired in signals that need to have their waveform direct, promoting several problems in the single-phase converter, for exemple: difficulty in its control; increasing the size and decreasing the life time of the elements which make up it; and decreasing of the life time of the devices connected to its DC and/or AC side. In this work it is done a deep study of the single-phase converters, either the VSC or the CSC, working as the three kind of energy conversion addressed here: AC-DC, DC-AC and AC-DC-AC conversion. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/3273
dc.date.accessioned 2019-03-27T16:24:32Z
dc.date.available 2019-03-27
dc.date.available 2019-03-27T16:24:32Z
dc.type Tese pt_BR
dc.subject Bombeamento Fotovoltaico.
dc.subject Compensação da Potência Oscilatória.
dc.subject Conversor Fonte de Corrente.
dc.subject Conversor Fonte de Tensão.
dc.subject Monofásico.
dc.subject Photovoltaic Pumping.
dc.subject Oscillatory Power Compensation.
dc.subject Current Source Converter.
dc.subject Voltage Source Converter.
dc.subject Single Phase.
dc.rights Acesso Aberto pt_BR
dc.creator VITORINO, Montiê Alves.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Optimization of energy processing in photovoltaic pumping systems and single-phase conversion. pt_BR
dc.identifier.citation VITORINO, Montiê Alves. Otimização do processamento da energia em sistemas de bombeamento fotovoltaico e conversão monofásica. 2012. 302f. Tese (Doutorado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2012. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta