DSpace/Manakin Repository

Estudos para implantação de um modelo de ventilação sob demanda no complexo mineiro de Ipueira-Ferbasa, município de Andorinha-Bahia.

Mostrar registro simples

dc.creator.ID COSTA, J. C. A. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/5648923977269111 pt_BR
dc.contributor.advisor1 GRILO, Marcelo Bezerra.
dc.contributor.advisor1ID GRILO, M. B. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/9758227561901031 pt_BR
dc.contributor.referee1 LIMA, Antônio Gilson Barbosa de.
dc.contributor.referee2 BONATES, Eduardo Jorge Lira.
dc.contributor.referee3 LIMA, Aarão de Andrade.
dc.contributor.referee4 VIDAL, Francisco Wilson Hollanda.
dc.description.resumo Este trabalho apresenta o desenvolvimento de uma pesquisa para a implantação de um modelo de ventilação sob demanda em uma mina subterrânea de grande porte. Trata-se da mina Ipueira, pertencente ao Grupo Ferbasa, localizada no Estado da Bahia, Região Nordeste do Brasil. O processo de ventilação sob demanda (VOD) é o resultado de estudos recentes, que tiveram um maior impulso na última década, e que consiste em variar o suprimento de ar nas diversas áreas da mina de acordo com as necessidades exigidas em cada setor em um dado momento. As quantidades de ar requeridas sofrem modificações de acordo com as alterações dos diversos fatores (concentração de gases, temperatura, poeira, etc.) que dependem, por sua vez, da operação executada, do número de pessoas envolvidas e do tipo e quantidade de equipamentos a diesel solicitados. Os sistemas de ventilação tradicionais tendem a operar com sua capacidade máxima, necessária para manter o suprimento de ar requerido, que por questões de segurança, normalmente é calculado com base em um cenário o mais pessimista possível. Por esse motivo, apresentam forte tendência para um maior consumo de energia em relação aos sistemas de ventilação sob demanda. Isso também justifica o interesse crescente pelo tema e o consequente aumento do número de estudos e aplicações do modelo em minas do mundo inteiro. Pela constatação de que esses estudos e suas aplicações são pouco difundidos no Brasil, a presente pesquisa se propõe a contribuir para uma mudança desse quadro. A metodologia, proposta pela pesquisa, tem por base a elaboração de diagnóstico completo do sistema de ventilação existente na mina Ipueira, principalmente no que se refere ao seu consumo de energia. Esse diagnóstico torna-se necessário, tanto para a adoção de medidas cabíveis, como para se estabelecer comparações entre os resultados anteriores e posteriores à implantação do modelo. As simulações realizadas, além de todos os levantamentos e testes necessários, apontam para um resultado bastante otimista no que se refere à economia obtida com a redução do consumo energético pelo sistema de ventilação. A economia mensal, de todo o sistema de ventilação da mina Ipueira, após a implantação do modelo de ventilação sob demanda, ficou prevista em torno de 26%. Esse resultado pode atingir contornos ainda mais significativos com a adoção de outras medidas de aperfeiçoamento do sistema, conforme indicado no corpo da presente tese. por
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA DE PROCESSOS pt_BR
dc.publisher.initials UFCG pt_BR
dc.title Estudos para implantação de um modelo de ventilação sob demanda no complexo mineiro de Ipueira-Ferbasa, município de Andorinha-Bahia. pt_BR
dc.date.issued 2017-02-24
dc.description.abstract This work presents the development of a research for the implementation of a model of ventilation on demand (VOD) in a large underground mine. This is the Ipueira mine belonging to the Ferbasa Group, located in the State of Bahia, Northeastern Brazil. The ventilation on demand (VOD) process is the result of recent studies, which have been boosted in the last decade, and it consists in varying the air supply in the various areas of the mine according to the needs of each sector at a given time. The amounts of air required are modified according to the changes in the various factors (gas concentration, temperature, dust, etc.) which in turn depend on the operation performed, the number of personnel involved and the type and quantity of diesel equipment in operation.Traditional ventilation systems tend to operate at their maximum capacity, necessary to maintain the required air supply, which for safety reasons is usually calculated based on the most pessimistic scenario possible. For this reason, they have a strong tendency towards higher energy consumption compared to ventilation on demand systems. This also justifies the growing interest in the theme and the consequent increase in the number of studies and applications of the model in mines around the world. Based on the fact that these studies and their applications are not widespread in Brazil, the present research proposes to contribute to a change in this situation. The methodology, proposed by the research, is based on the elaboration of a complete diagnosis of the existing ventilation system at the Ipueira mine, mainly in terms of its energy consumption. This diagnosis is necessary, both for the adoption of appropriate measures, and to establish comparisons between the results before and after the implantation of the VOD model. The simulations carried out, in addition to all the necessary surveys and tests, point to a very optimistic result regarding the economy obtained by reducing the energy consumption by the ventilation system. The monthly savings of the entire ventilation system at the Ipueira mine after the implementation of the ventilation on demand model was estimated at around 26%. This result can reach even more significant levels with the adoption of other system improvement measures, as indicated in the body of the present thesis. eng
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/368
dc.date.accessioned 2018-04-12T15:28:43Z
dc.date.available 2018-04-12
dc.date.available 2018-04-12T15:28:43Z
dc.type Tese pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator COSTA, José César de Albuquerque.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.identifier.citation COSTA, Jose César de Albuquerque. Estudos para implantação de um modelo de ventilação sob demanda no Complexo Mineiro de Ipueira-Ferbasa, município de Andorinha-Bahia . 2017. 95 f. Tese (Doutorado em Engenharia de Processos) – Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2017. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/368 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta