DSpace/Manakin Repository

Análise de conformidade de SPDA segundo a NBR 5419/2015: um estudo de caso.

Mostrar registro simples

dc.creator.ID SILVA, J. A. S. pt_BR
dc.contributor.advisor1 SOUZA, Ronimack Trajano de.
dc.contributor.advisor1ID SOUZA, R. T. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0855145610768901 pt_BR
dc.contributor.referee1 ARAÚJO, Jalberth Fernandes de.
dc.contributor.referee1ID ARAÚJO, J. F. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/6903049112797651 pt_BR
dc.description.resumo O estudo sobre descargas atmosféricas destaca que, embora não seja possível impedir sua ocorrência, é fundamental adotar medidas de proteção para minimizar seus impactos. O Brasil lidera o ranking mundial de incidência de raios, com cerca de 78 milhões de descargas anuais, resultando em 2.194 mortes entre os anos 2000 e 2019, conforme dados do INPE (2024). As descargas representam riscos significativos para estruturas, pessoas e equipamentos, o que torna essencial a implementação de Sistemas de Proteção contra Descargas Atmosféricas (SPDA), conforme orienta a NBR 5419/2015. O SPDA é composto por um sistema externo (captadores, condutores de descida e aterramento) e um sistema interno, que inclui Dispositivos de Proteção contra Surtos (DPS) para mitigar os efeitos elétricos das descargas. Além disso, o correto dimensionamento do aterramento é crucial para a segurança das instalações elétricas. No entanto, muitas instalações de SPDA não seguem as normas técnicas devido a falhas de planejamento, uso de materiais inadequados, falta de manutenção e profissionais não qualificados, o que aumenta os riscos à vida humana e ao patrimônio. Este trabalho visa analisar a conformidade e a eficiência de Sistemas de Proteção contra Descargas Atmosféricas (SPDA) instalados em edificações no município de Campina Grande, PB, e sugerir melhorias para corrigir falhas e aprimorar a segurança das instalações. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica pt_BR
dc.title Análise de conformidade de SPDA segundo a NBR 5419/2015: um estudo de caso. pt_BR
dc.date.issued 2024-10-10
dc.description.abstract The study on lightning discharges highlights that, although it is impossible to prevent their occurrence, it is essential to adopt protective measures to minimize their impacts. Brazil leads the global ranking in lightning incidence, with approximately 78 million discharges annually, resulting in 2,194 deaths between 2000 and 2019, according to data from INPE (2024). Lightning poses significant risks to structures, people, and equipment, making it crucial to implement Lightning Protection Systems (LPS) as guided by NBR 5419/2015. The LPS is composed of an external system (air terminals, down conductors, and grounding) and an internal system, which includes Surge Protection Devices (SPD) to mitigate the electrical effects of lightning strikes. Furthermore, proper grounding design is essential for the safety of electrical installations. However, many LPS installations do not comply with technical standards due to poor planning, the use of inadequate materials, lack of maintenance, and unqualified professionals, increasing risks to human life and property. This study aims to analyze the compliance and efficiency of Lightning Protection Systems (LPS) installed in buildings in the municipality of Campina Grande, PB, and suggest improvements to correct faults and enhance the safety of installations. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/38599
dc.date.accessioned 2024-10-18T22:32:36Z
dc.date.available 2024-10-18
dc.date.available 2024-10-18T22:32:36Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Proteção de Sistemas Elétricos pt_BR
dc.subject Sistemas de Proteção contra Descargas Atmosféricas (SPDA) pt_BR
dc.subject ABNT NBR 5419/2015 pt_BR
dc.subject Protection of Electrical Systems pt_BR
dc.subject Lightning Protection Systems (LPS) pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Járede Aguiar Sousa.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative SPDA compliance analysis according to NBR 5419/2015: a case study. pt_BR
dc.identifier.citation SILVA, Járede Aguiar Sousa. Análise de conformidade de SPDA segundo a NBR 5419/2015: um estudo de caso. 2024. 69 f. Monografia (Bacharelado em Engenharia Elétrica) - Universidade Federal de Campina Grande, Centro de Engenharia Elétrica e Informática, Campina Grande, Paraíba, Brasil, 2024. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta