DSpace/Manakin Repository

Avaliação de conformidade de instalações elétricas com normas técnicas e de segurança em edifícios comerciais e residenciais no município de São Vicente do Seridó-PB.

Mostrar registro simples

dc.creator.ID SANTOS, J. V. O. pt_BR
dc.contributor.advisor1 SOUZA, Ronimack Trajano de.
dc.contributor.advisor1ID SOUZA, R. T. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/0855145610768901 pt_BR
dc.contributor.referee1 SILVA, Célio Anésio da.
dc.contributor.referee1ID SILVA, C. A. pt_BR
dc.contributor.referee1Lattes http://lattes.cnpq.br/6105337488345986 pt_BR
dc.description.resumo O amplo uso da energia elétrica no cotidiano, em seus variados cenários, acabam expondo usuários e/ou técnicos aos riscos inerentes à utilização da energia elétrica. Esses riscos são aumentados significativamente quando as instalações elétricas não foram projetadas e/ou executadas conforme as diretrizes das normas técnicas e norma regulamentadora nº 10, apresentando inconformidades que podem expor os usuários a acidentes, inclusive fatais. Este trabalho, por sua vez, propôs-se a realizar análises de conformidade nas instalações elétricas de residências e comércios no município de São Vicente do Seridó-PB, sob a luz das diretrizes estabelecidas na norma técnica NBR 5410:2004. Para tal, selecionou-se as unidades que teriam suas instalações elétricas inspecionas, totalizando dez unidades, sendo seis unidades residenciais e quatro unidades comerciais. Mediante as análises desenvolvidas, por meio de inspeções visuais às unidades em estudo, considerou-se as principais inconformidades e desenvolveu-se sugestões afim de solucioná-las e torná-las conforme com os itens propostos na norma em questão. O trabalho conclui-se sugerindo, além das devidas adequações aos itens propostos pelas normas de segurança, conforme citado anteriormente, medidas que possam ajudar na conscientização dos usuários da energia elétrica, visando dessa maneira, mitigar os riscos inerentes a utilização da eletricidade e reduzir ainda mais os números de acidentes ocasionados pela má utilização da mesma. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica pt_BR
dc.title Avaliação de conformidade de instalações elétricas com normas técnicas e de segurança em edifícios comerciais e residenciais no município de São Vicente do Seridó-PB. pt_BR
dc.date.issued 2024
dc.description.abstract The widespread use of electricity in daily life, across its various contexts, exposes users and/or technicians to the inherent risks associated with electricity use. These risks are significantly heightened when electrical installations are not designed and/or executed according to the guidelines of technical standards and Regulatory Norm No. 10, presenting non-compliances that can expose users to accidents, including fatal ones. This study aimed to conduct compliance analyses of the electrical installations in residences and businesses in the municipality of São Vicente do Seridó – PB, in light of the guidelines established in the technical standard NBR5410:2004. For this purpose, ten units were selected for inspection, comprising six residential units and four commercial units. Based on the analyses carried out through visual inspections of the units under study, the main non-compliances were identified, and suggestions were developed to address them and ensure compliance with the items proposed in the standard. The study concludes by recommending, in addition to the necessary adjustments to the items proposed by safety standards, measures that can help raise awareness among electricity users, thereby aiming to mitigate the inherent risks of electricity use and further reduce the number of accidents caused by its misuse. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/38603
dc.date.accessioned 2024-10-19T02:25:44Z
dc.date.available 2024-10-18
dc.date.available 2024-10-19T02:25:44Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Segurança Elétrica pt_BR
dc.subject NBR 5410/2004 pt_BR
dc.subject NR-10 pt_BR
dc.subject Instalações Elétricas pt_BR
dc.subject Eletricidade pt_BR
dc.subject Choque Elétricos – Proteção pt_BR
dc.subject Electrical Safety pt_BR
dc.subject Electrical Installations pt_BR
dc.subject Electricity pt_BR
dc.subject Electric Shocks – Protection pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SANTOS, João Venâncio Oliveira.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Assessment of compliance of electrical installations with technical and safety standards in commercial and residential buildings in the municipality of São Vicente do Seridó-PB. pt_BR
dc.identifier.citation SANTOS, João Venâncio Oliveira. Avaliação de conformidade de instalações elétricas com normas técnicas e de segurança em edifícios comerciais e residenciais no município de São Vicente do Seridó-PB. 2024. 56 f. Monografia (Bacharelado em Engenharia Elétrica) - Universidade Federal de Campina Grande, Centro de Engenharia Elétrica e Informática, Campina Grande, Paraíba, Brasil, 2024. pt_BR