CRUZ, Raimundo Leite.; MATOS, José de Arimatea de.; GOMES, Tamara Maria.
Resumo:
The aim of this work is to evaluate the GFT model Carborundum drip
field performance. This evaluation was made using four different methods for the
calculation of the water distribution uniformity estimation. Having a manufacturing
variation coefficient of 0.024 and working in a 150 kPa pressure, it was observed that the
uniformity coefficient varied from 84.29% to 90.76%, such valves classify the emitting