dc.description.resumo |
A água trata-se do constituinte mais característico e abundante da Terra. Bem comum e
indispensável à humanidade, destina-se aos mais diversos fins, desde ao consumo
humano até o uso industrial; podendo ser caracterizada como a forma de energia mais
essencial à vida e à manutenção dos ecossistemas. Apesar de sua imensa importância e
essencialidade à existência de vida na Terra verifica-se uma indolência inaceitável
quanto a gestão e conservação dos recursos hídricos do nosso planeta. Em virtude disto
busca-se melhorar a qualidade de vida e minimizar o problema de falta de água potável,
este trabalho tem como objetivo avaliar o processo de dessalinização via osmose inversa
usando energia solar fotovoltaica, seus consumos energéticos e custos. Para isso foi
desenvolvido e instalado no Laboratório de Referência em Dessalinização (LABDES),
na Universidade Federal de Campina Grande, um sistema constituído de duas
membranas de osmose inversa, alimentado por um conjunto de dezesseis painéis
fotovoltaicos. O desempenho do sistema foi avaliado com soluções de cloreto de sódio
com concentração variando de 1000, 1200, 1500 e 2000mg/L. As variáveis medidas,
como: pressão, tensão, corrente e vazão as quais foram obtidas através dos sensores
elétricos e armazenadas no computador pelo Software Data Aquisition permitiram
avaliar os seguintes parâmetros: corrente elétrica, tensão do motor, potência elétrica,
vazões do permeado e concentrado, recuperação e consumo de energia por m³ de água
produzida. As concentrações de água de alimentação e irradiação solar influenciam
consideravelmente a pressão, e conseqüentemente a produção de água permeada. O
sistema mostrou condições técnicas de produzir 0,17 m³/h de água dessalinizada a um
custo de R$ 6.78. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Ciências e Tecnologia - CCT |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA QUÍMICA |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.subject.cnpq |
Engenharia Química |
pt_BR |
dc.subject.cnpq |
Água |
pt_BR |
dc.title |
Avaliação de um dessalinizador via osmose inversa usando energia solar fotovoltaica: estudo do consumo energético e custos. |
pt_BR |
dc.date.issued |
2008-03-25 |
|
dc.description.abstract |
Water is the most characteristic and abundant constituent of the Earth. Well common
and essential to humanity, is the most diverse purposes, provided for human
consumption until the industrial use, can be characterized as a form of energy more
essential to life and the maintenance of ecosystems. Despite its enormous importance
and essentiality to the existence of life on earth there is an earnestness unacceptable as
the management and conservation of water resources of our planet. Because of this
quest is to improve the quality of life and minimize the problem of lack of drinking
water, this work aims at evaluating the process of desalination by reverse osmosis using
solar photovoltaics, their energy consumption and costs. For that has been developed
and installed at the Reference Laboratory in Desalination (LABDES), at the Federal
University of Campina Grande, a system consists of two membranes, reverse osmosis,
powered by a set of sixteen photovoltaic panels. The performance of the system was
evaluated with sodium chloride solutions with concentrations ranging from 1000, 1200,
1500 and 2000 mg/L. Variables measures such as: pressure, voltage, current flow and
which were obtained through the electric sensors and stored on the computer by the
Software Data Aquisition allowed to assess the following parameters: current, voltage
of the engine, electric power, flow rates of the permeate and concentrate , retrieval and
consumption of energy per m3 of water produced. Concentrations of water, food
irradiation and solar influence considerably the pressure, and consequently the
production of water permeate. The system showed technical conditions to produce 0.17
m³ / h of desalinated water at a cost of $ 6.78. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4017 |
|
dc.date.accessioned |
2019-05-29T20:14:29Z |
|
dc.date.available |
2019-05-29 |
|
dc.date.available |
2019-05-29T20:14:29Z |
|
dc.type |
Dissertação |
pt_BR |
dc.subject |
Água |
pt_BR |
dc.subject |
Dessalinização |
pt_BR |
dc.subject |
Osmose Inversa |
pt_BR |
dc.subject |
Painel Fotovoltaico |
pt_BR |
dc.subject |
Water |
pt_BR |
dc.subject |
Reverse Osmosis |
pt_BR |
dc.subject |
Desalination |
pt_BR |
dc.subject |
Photovoltaic Panel |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
SOARES, Ana Karla Crispim. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Evaluation of a desalinator via reverse osmosis using photovoltaic solar energy: study of energy consumption and costs. |
pt_BR |
dc.description.sponsorship |
Capes |
pt_BR |
dc.identifier.citation |
SOARES, A. K. C. Avaliação de um dessalinizador via osmose inversa usando energia solar fotovoltaica: estudo do consumo energético e custos. 2008. 97 f. Dissertação (Mestrado em Engenharia Química) – Programa de Pós-Graduação em Engenharia Química, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil, 2008. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4017 |
pt_BR |