DSpace Repository

análise estrutural em cobertura cônica de silo cilíndrico metálico pelo método dos elementos finitos

Show simple item record

dc.creator.ID RODRIGUES, H. C. S. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0161988131457910 pt_BR
dc.contributor.advisor1 NASCIMENTO, José Wallace Barbosa do.
dc.contributor.advisor1ID NASCIMENTO, J. W. B. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/9274991135144621 pt_BR
dc.contributor.referee1 LOPES NETO, José Pinheiro
dc.contributor.referee2 CALIL JÚNIOR, Carlito.
dc.contributor.referee3 CHEUNG, Andrés Batista.
dc.description.resumo No Brasil, as falhas estruturais de silos cilíndricos metálicos têm acontecido com uma frequência maior do que as falhas nas demais estruturas. Esses colapsos podem ter como causa a ausência de recomendações normatizadas, tanto para o cálculo das ações quanto para o cálculo da resistência dos elementos estruturais dos silos. Diante desse contexto, neste trabalho objetivou-se estabelecer modelos para estimar as ações em coberturas cônicas de silos metálicos para empregá-las em análises de estabilidade linear, dos esforços internos, e dimensionamento. Dessa forma, no cálculo da ação vento, os modelos para estimar os coeficientes de pressão externa da cobertura foram determinados com a série de Fourier a partir dos dados experimentais produzidos por Kabeli (2002). Para o cálculo das ações dos cabos de termometria foi estabelecido o modelo de Schwab et al. (1991). Com o software SCIA Engineer, o qual emprega o método dos elementos finitos, foram realizadas as análises de estabilidade linear para três estruturas. A primeira não possuía sistema de contraventamento, enquanto as demais foram avaliadas com tal sistema. O resultado dessas análises tornou evidente que os sistemas de contraventamento conferiram maior estabilidade as estruturas de coberturas cônicas. Na análise de estabilidade, foi notado que os menores valores dos fatores de carga foram calculados para a combinação das ações na qual a ação dos cabos de termometria atuou como ação variável principal. Os esforços internos foram determinados conforme preconiza a NBR 8800 (ABNT, 2008), a partir de análises de primeira e de segunda ordem. O dimensionamento das vigas radiais (longarinas) e das vigas poligonais (travessas), foram realizadas de acordo com as recomendações da norma NBR 14762 (ABNT, 2010). Nessas análises, respectivamente, o fator de verificação desses elementos foi igual a 0,94 (94%) e 0,52 (52%). pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Agrícola pt_BR
dc.title análise estrutural em cobertura cônica de silo cilíndrico metálico pelo método dos elementos finitos pt_BR
dc.date.issued 2022-01-18
dc.description.abstract In Brazil, structural failures of cylindrical steel silos have occurred more frequently than failures in other structures. These collapses may be caused by the absence of standardized recommendations, both for calculating the actions and for calculating the resistance of the structural elements of the silos. In this context, the objective of this work was to establish models to estimate the actions in conical roof of steel silos to use them in linear stability analyses, internal forces, and dimensioning. Thus, in the wind action calculation, the models to estimate the external pressure coefficients of the roof were determined with the Fourier series from the experimental data produced by Kabeli (2002). To calculate the actions of the thermometry cables, the model of Schwab et al. (1991) was established. With the SCIA Engineer software, which uses the finite element method, linear stability analyses were performed for three structures, the first without a bracing system, and the others with. The result of these analyses made it evident that the bracing systems provided greater stability to the conical roof structures. In the stability analysis, it was observed that the lowest values of the load factors were calculated for the combination of actions in which the action of the thermometry cables acted as the main variable action. The internal efforts were determined as recommended by NBR 8800 (ABNT, 2008) based on first and second order analyses. The design of the radial beams (stringers) and the polygonal beams (crossbeams) were carried out according to the recommendations of the NBR 14.762 (ABNT, 2010) standard. In these analyses, respectively, the verification factor of these elements was equal to 0.94 (94%) and 0.52 (52%). pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/40893
dc.date.accessioned 2025-03-06T13:03:44Z
dc.date.available 2025-03-06
dc.date.available 2025-03-06T13:03:44Z
dc.type Dissertação pt_BR
dc.subject SCIA Engineer pt_BR
dc.subject Análise de estabilidade linear pt_BR
dc.subject Análise de elementos finitos pt_BR
dc.subject Cabos de termometria pt_BR
dc.subject Ação do vento pt_BR
dc.subject Cobertura de silos pt_BR
dc.subject SCIA Engineer pt_BR
dc.subject Linear buckling analysis pt_BR
dc.subject Finite element analysis pt_BR
dc.subject Thermometry cables pt_BR
dc.subject Wind action pt_BR
dc.subject Roof of silos pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator RODRIGUES, Hygor Cesar Soares
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Structural Analysis in Conical Silo Roof cylindrical metal by the finite element method pt_BR
dc.description.sponsorship CNPq pt_BR
dc.identifier.citation RODRIGUES, Hygor Cesar Soares. Análise estrutural em cobertura cônica de silo cilíndrico metálico pelo método dos elementos finitos. 2024. 112 f. Dissertação (Mestrado em Engenharia Agrícola), Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Paraíba, Brasil, 2024. pt_BR