Desenvolvimento de dispositivo para treinamento dos músculos do assoalho pélvico por manufatura aditiva

Show simple item record

dc.creator.ID MARTINS, K. Y. N. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0498620439645521 pt_BR
dc.contributor.advisor1 Rodrigues, John Kennedy Guedes
dc.contributor.advisor1ID RODRIGUES, J. K. G. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/7834302744515283 pt_BR
dc.contributor.advisor-co1 SILVA, Jorge Vicente Lopes da.
dc.contributor.advisor-co1ID DA SILVA, JORGE V.L. pt_BR
dc.contributor.advisor-co1Lattes http://lattes.cnpq.br/6139204122148876 pt_BR
dc.contributor.referee1 LIMA, Maria do Carmo Pinto.
dc.contributor.referee2 OLIVEIRA, Eduardo Jorge Valadares.
dc.contributor.referee3 GALDINO, Kátia Elizabete.
dc.contributor.referee4 NORITO, Pedro Yoshito.
dc.description.resumo A demanda por novos produtos aliada ao surgimento de novas técnicas de manufatura e à união de ciências promissoras possibilita o desenvolvimento de dispositivos customizados para a saúde feminina. Neste cenário, dispositivos de biofeedback mecânico que atuam como adjuvantes no tratamento das disfunções do assoalho pélvico, desenvolvidos com características customizadas utilizando novas tecnologias, podem fornecer informações durante o seu uso por meio de estímulos visuais e sensoriais. Diante disso, esta pesquisa teve como objetivo desenvolver um dispositivo mecânico para treinamento dos músculos do assoalho pélvico com uso da manufatura aditiva. O estudo realizado foi de caráter científico de natureza aplicada, com objetivo exploratório, de abordagem qualitativa, a partir do método de pesquisa-ação, sendo dividido em seis etapas: análise biomimética, desenvolvimento conceptivo, modelagem 3D, simulação computacional, fabricação por manufatura aditiva, teste de bancada e análise do protótipo por profissionais da saúde. Para o desenvolvimento conceitual e parametrização do dispositivo adotou-se a bioinspiração no caju e no canal vaginal, sendo utilizados recursos como o escaneamento 3D e imagens de TC para obtenção dos contornos, que serviram como base para modelagem do dispositivo em softwares CAD. A partir da simulação computacional de elementos finitos, o dispositivo foi aprovado para uso quanto à capacidade de permitir a realização de contrações voluntárias do assoalho pélvico durante o treinamento dos músculos do assoalho pélvico (TMAP). A fabricação feita por MA utilizando a tecnologia MJP 3 Polyjet foi satisfatória para validar o modelo do design. Ao submeter o dispositivo a prática simulada em modelo anatômico, constatou-se que os requisitos pretendidos na concepção inicial foram atendidos, com destaque para a visibilidade do dispositivo pela paciente, durante o uso, em posição de litotomia. O protótipo do dispositivo ao ser analisado por profissionais da saúde foi bem avaliado e considerado apropriado para uso. Desta forma, o estudo mostrou-se satisfatório em todas as suas fases, desde a concepção inicial até as etapas de modelagem, simulação e fabricação. O desenvolvimento de um dispositivo mecânico para TMAP utilizando MA tem o potencial de aprimorar o tratamento em ambiente clínico e facilitar a continuidade da terapia pela paciente em domicílio, oferecendo uma abordagem integrada e eficaz para o cuidado com a saúde. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA DE PROCESSOS pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia de Processos pt_BR
dc.title Desenvolvimento de dispositivo para treinamento dos músculos do assoalho pélvico por manufatura aditiva pt_BR
dc.date.issued 2024-03-27
dc.description.abstract The demand for new products combined with the emergence of new manufacturing techniques and the combination of promising sciences makes it possible to develop customized devices for women's health. In this scenario, mechanical biofeedback devices that act as adjuvants in the treatment of pelvic floor disorders, developed with customized characteristics using new technologies, can provide information during their use through visual and sensory stimuli. Therefore, this research aimed to develop a mechanical device for training the pelvic floor muscles using additive manufacturing. The study carried out was of a scientific nature of an applied nature, with an exploratory objective, with a qualitative approach, based on the action research method, being divided into six stages: biomimetic analysis, conceptual development, 3D modeling, computer simulation, manufacturing by additive manufacturing, bench testing and analysis of the prototype by healthcare professionals. For the conceptual development and parameterization of the device, bioinspiration was adopted from cashews and the vaginal canal, using resources such as 3D scanning and CT images to obtain the contours, which served as the basis for modeling the device in CAD software. Based on computational finite element simulation, the device was approved for use in terms of its ability to allow voluntary contractions of the pelvic floor during pelvic floor muscle training (PFMT). The manufacturing carried out by MA using MJP 3 Polyjet technology was satisfactory for validating the design model. When submitting the device to simulated practice in an anatomical model, it was found that the requirements intended in the initial design were met, with emphasis on the visibility of the device by the patient, during use, in the lithotomy position. The device prototype, when analyzed by health professionals, was well evaluated and considered appropriate for use. In this way, the study proved to be satisfactory in all its phases, from the initial conception to the modeling, simulation and manufacturing stages. The development of a mechanical device for PFMT using AM has the potential to improve treatment in a clinical environment and facilitate the continuation of therapy by the patient at home, offering an integrated and effective approach to healthcare. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/41140
dc.date.accessioned 2025-03-18T12:56:59Z
dc.date.available 2025-03-17
dc.date.available 2025-03-18T12:56:59Z
dc.type Tese pt_BR
dc.subject Dispositivo médico pt_BR
dc.subject Biomimética pt_BR
dc.subject Simulação por computador pt_BR
dc.subject Manufatura Aditiva pt_BR
dc.subject Distúrbios do assoalho pélvico pt_BR
dc.subject Equipment and Supplies pt_BR
dc.subject Biomimetics pt_BR
dc.subject Computer Simulation pt_BR
dc.subject Additive manufacturing pt_BR
dc.subject Pelvic floor disorders pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator MARTINS, Ketinlly Yasmyne Nascimento.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Development of a device for training pelvic floor muscles by additive manufacturing pt_BR
dc.description.sponsorship CNPq pt_BR
dc.description.sponsorship Capes pt_BR
dc.identifier.citation MARTINS, Ketinlly Yasmyne Nascimento. Desenvolvimento de dispositivo para treinamento dos músculos do assoalho pélvico por manufatura aditiva. 2024. 105 f. Tese (Doutorado em Engenharia de Processos) – Programa de Pós-Graduação em Engenharia de Processos, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande, Paraíba, Brasil,2024. pt_BR