Incerteza na medição de velocidade de fluido usando anemômetro com um único sensor aquecido.

Mostrar registro simples

dc.creator.ID SANTANA, D. V. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/1936763571544917 pt_BR
dc.contributor.advisor1 FREIRE, Raimundo Carlos Silvério.
dc.contributor.advisor1ID FREIRE, R. C. S. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4016576596215504 pt_BR
dc.contributor.advisor2 OLIVEIRA, Amauri.
dc.contributor.advisor2ID OLIVEIRA, A. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/3603816381832077 pt_BR
dc.contributor.referee1 LUCIANO, Benedito Antonio.
dc.contributor.referee2 DUPOUY, Emmanuel.
dc.description.resumo No anemómetro a fio quente convencional, o sensor aquecido sofre influências tanto da velocidade quanto da temperatura do fluido. Por este motivo, se faz necessária a utilização de um circuito auxiliar para medição da temperatura do fluido chamado de circuito de compensação. O anemómetro a fio quente com sensor único utiliza o chaveamento de resistores para compensar a temperatura do fluido, apresentando como vantagem a utilização de apenas um sensor, porém apresenta incerteza na medição de velocidade variável do fluido. O presente trabalho propõe um modelo matemático do CTA com sensor único e uma solução capaz de minimizar o erro na estimativa de velocidades variáveis. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.title Incerteza na medição de velocidade de fluido usando anemômetro com um único sensor aquecido. pt_BR
dc.date.issued 2010-12
dc.description.abstract In a conventional hot wire anemometer, the heated sensor is influenced both by the speed and the temperature of the fluid. For this reason, it is necessary to use an auxiliary circuit to measure the fluid temperature, so called compensation circuit. The single sensor hot wire anemometer switches the resistors to compensate the fluid temperature. Although this configuration has the advantage of using a single sensor, it has as a disadvantage the uncertainty in the measurement of variable fluid speeds. This paper proposes a mathematical model of the CTA with a single sensor and a solution that minimizes the error in the estimation of variable speeds. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/4176
dc.date.accessioned 2019-06-06T16:59:28Z
dc.date.available 2019-06-06
dc.date.available 2019-06-06T16:59:28Z
dc.type Dissertação pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SANTANA, Dennis Viana.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Uncertainty in measuring fluid velocity using anemometer with a single heated sensor. pt_BR
dc.identifier.citation SANTANA, Dennis Viana. Incerteza na medição de velocidade de fluido usando anemômetro com um único sensor aquecido. 2010. 62f. (Dissertação de Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Paraíba Brasil, 2010. pt_BR