DSpace/Manakin Repository

Consumo hídrico de bananeira irrigada na região da chapada do Apodi.

Mostrar registro simples

dc.contributor.advisor1 SILVA, Bernardo Barbosa da.
dc.contributor.advisor1ID SILVA, B. B. da pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/8285693170429747 pt_BR
dc.contributor.advisor2 FISCH, Gilberto Fernando.
dc.contributor.advisor2ID Fisch, Gilberto F. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/0331228247415761 pt_BR
dc.contributor.referee1 AZEVEDO, Pedro Vieira de.
dc.contributor.referee2 ESPINOLA SOBRINHO, Jose.
dc.description.resumo A evapotranspiração (ETc) de um pomar de bananeiras cv. Pacovan Apodi (Musa sp., AAAB), irrigado por gotejamento, localizado na Fazenda Frutacor (5º 4’ 35”S; 37º 51’ 54”O; 131 m), em Quixeré-CE, foi obtida através do Método das Correlações Turbulentas durante o período de setembro de 2005 a setembro de 2006. Além disso, estimou-se também a evapotranspiração de referência (ETo) com o objetivo de determinar o coeficiente de cultura (Kc) do pomar. A eficiência do uso da água (EUA) foi determinada com base nos dados de produtividade e evapotranspiração do pomar. Empreendeu-se uma análise do balanço de energia da superfície vegetada que permitiu caracterizar a partição do saldo de radiação para os outros componentes, isto é, fluxo de calor latente, fluxo de calor sensível e fluxo de calor no solo, além de determinar o erro do fechamento da equação do balanço de energia. Os valores médios diários da ETc para todo o período experimental estiveram na faixa de 1,67 a 4,53 mm dia-1, com média de 3,40 mm dia-1. Os resultados do coeficiente de cultura mostraram um valor mínimo de 0,55 e um máximo de 1,0. Quanto à fração do saldo de radiação utilizada como fluxo de calor latente, esta variou entre 0,5 e 0,92 (adimensional), com valor médio de 0,68. Com relação ao fluxo de calor sensível, esta partição foi de 0,13 a 0,44, com média de 0,28 e valores na faixa de -0,04 a 0,12, com média de 0,03, foram utilizados como fluxo de calor no solo. O erro de fechamento da equação do balanço de energia, obtido através da correlação entre H + LE e Rn – G, foi de cerca de 20%, o qual é semelhante àqueles encontrados na literatura. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM METEOROLOGIA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Meteorologia pt_BR
dc.title Consumo hídrico de bananeira irrigada na região da chapada do Apodi. pt_BR
dc.date.issued 2007-06-25
dc.description.abstract The evapotranspiration (ETc) from a drip irrigated banana orchard cv. Pacovan Apodi (Musa sp., AAAB), located in Fazenda Frutacor (5° 4' 35'' S; 37° 51' 54'' W; 131m), in Quixeré-CE was measured using the Eddy Covariance Method from September 2005 to September 2006. Besides, it was also considered the reference evapotranspiration (ETo) to achieve the crop coefficient (Kc) of the orchard. Water use efficiency (WUE) was obtained from yield and crop evapotranspiration. It has been accomplished energy balance over canopy that allowed to define the net radiation partition for the others components, that are, latent and sensible heat flux and soil heat flux, besides energy balance closure error was obtained. Daily average values of ETc for whole experimental period were in the strip from 1,67 to 4,53 mm day-1, with average of 3,40 mm day-1. Minimum value of crop coefficient was 0,55 and maximum, 1,0. In regarding to net radiation partition used as the latent heat flux was between 0,5 and 0,92 (adimensional), with average value of 0,68. Fraction of sensible heat flux was 0,13 to 0,44, with average value 0,28, while fraction used in soil heat flux was 0,04 to 0,12, which its average achieved 0,03. Closure error of energy balance equation, attained through correlation between Rn – G and H + LE, was about 20%, which is similar to that found in others researches. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/6185
dc.date.accessioned 2019-08-26T10:53:16Z
dc.date.available 2019-08-26
dc.date.available 2019-08-26T10:53:16Z
dc.type Dissertação pt_BR
dc.subject Balanço de Energia pt_BR
dc.subject Calor Latente pt_BR
dc.subject Musa Sp pt_BR
dc.subject Correlações Turbulentas pt_BR
dc.subject Energy Balance pt_BR
dc.subject Latent Heat pt_BR
dc.subject Eddy Covariance pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator COSTA, Patricia Cordão.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Water consumption of irrigated banana in the region of chapada do Apodi. pt_BR
dc.description.sponsorship CNPq pt_BR
dc.identifier.citation COSTA, P. C. Consumo hídrico de bananeira irrigada na região da chapada do Apodi. 2007. 65 f. Dissertação (Mestrado em Meteorologia) – Pós-Graduação em Meteorologia, Centro de Tecnologia e Recursos Naturais, Universidade Federal de Campina Grande, Paraíba, Brasil, 2007. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/6185 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta