DSpace/Manakin Repository

Estudo da qualidade de água residuária doméstica pós-tratada em fluxo descendente intermitente.

Mostrar registro simples

dc.creator.ID SOUSA, E. P. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/3313918789109314 pt_BR
dc.contributor.advisor1 QUEIROZ, Manoel Moisés Ferreira de.
dc.contributor.advisor1ID QUEIROZ, M. M. F. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/1086060806081518 pt_BR
dc.contributor.advisor2 ARAÚJO, Alfredina dos Santos.
dc.contributor.advisor2ID ARAÙJO, A. S. pt_BR
dc.contributor.advisor2Lattes http://lattes.cnpq.br/3755167376239169 pt_BR
dc.contributor.referee1 MARACAJÁ, Patrício Borges.
dc.contributor.referee2 PEREIRA JUNIOR, Ednaldo Barbosa.
dc.description.resumo A presente pesquisa investigou o desempenho do pós-tratamento de efluente de tanque séptico em filtros de areia de fluxos intermitentes, visando obter um esgoto tratado com qualidade adequada para reuso na irrigação. O esgoto doméstico foi proveniente do bloco de aulas II do Centro de Ciências e Tecnologia Agroalimentar (CCTA), da Universidade Federal de Campina Grande (UFCG). O controle de entrada do fluxo no sistema também foi quantificado. O sistema experimental foi constituído de um tanque séptico, três filtros de areia com fluxo intermitente e uma caixa de armazenamento. Os três filtros aeróbios de areia foram preenchidos com brita e areia na seguinte proporção: 10 cm de brita nº 1 na base, 50 cm de areia na porção mediana e 5 cm de brita nº 0 na porção superior. A areia utilizada nos três filtros foi a mesma, sendo peneirada numa peneira com diâmetro de 0,50 mm. O primeiro filtro recebeu 200 L/dia (50 L a cada 6hs) de efluente do tanque séptico, o segundo filtro recebeu 150 L/dia (50 L a cada 8hs) e o terceiro filtro recebeu 100 L/dia (50 L a cada 12hs). Realizaram-se campanhas de medição, no período de Novembro/2014 a Fevereiro/2015 para caracterizar os efluentes nos aspectos físico-químicos e microbiológicos como indicadores de transformação da qualidade da água. Os parâmetros analisados foram: OD, temperatura, turbidez, pH, CE, cor, dureza total, Ca, Mg, cloretos, N, Na, K, P, DQO, DBO5, CT, CTT e E.coli. A análise de variância (ANOVA) foi realizada para comparar as concentrações de todos os parâmetros entre os efluentes, com nível de significância de 5%. Temperatura, turbidez, CE, cor, dureza total, Ca, Mg, cloretos, Na, K, P, DQO, DBO5, CT, CTT e E.coli não apresentaram diferenças estatísticas significantes. O OD apresentou significância. O N, muita significância e o pH, extrema significância estatística. Os filtros reduziram as concentrações de nutrientes, matéria orgânica e microorganismos patógenos, porém, com os reduzidos tempos de intermitências adotados não foi possível encontrar diferenças estatísticas entre os tratamentos. Os valores encontrados não foram compatíveis com os recomendados para uso na agricultura, segundo a Resolução do CONAMA. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia Agroalimentar - CCTA pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM SISTEMAS AGROINDUSTRIAIS pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Ciências Agrárias pt_BR
dc.title Estudo da qualidade de água residuária doméstica pós-tratada em fluxo descendente intermitente. pt_BR
dc.date.issued 2015
dc.description.abstract This research investigated the performance of the post-treatment of septic tank effluent sand filters intermittent flows, to obtain a treaty with sewage quality suitable for reuse in irrigation. The sewage was coming from the classes of block II of the Center for Science and Technology Agrifood (CCTA), the Federal University of Campina Grande (UFCG). The input flow control in the system was also quantified. The experimental system was composed of a septic tank of three sand filters with intermittent flow and a storage box. The three aerobic sand filters were filled with gravel and sand at the following ratio: 10 cm crushed base # 1, 50 cm in the middle portion sand and crushed stone No. 5 0 cm in the upper portion. The sand used in the three filters was the same, being sieved through a sieve with a diameter of 0.50 mm. The first filter received 200 L / day (50 L each 6am) of effluent from septic tank, the second filter received 150 L / day (50 L every 8h) filter and the third received 100 L / day (50 L each 12pm). There were measurement campaigns, from November / 2014 to February / 2015 to characterize the effluents in the physical, chemical and microbiological aspects as processing indicators of water quality. The parameters analyzed were: OD, temperature, turbidity, pH, EC, color, total hardness, Ca, Mg, chlorides, N, Na, K, P, COD, BOD 5, CT, CTT and E. coli. The analysis of variance (ANOVA) was performed to compare the concentrations of all the parameters in the effluent, at 5% significance level. Temperature, turbidity, EC, color, total hardness, Ca, Mg, chlorides, Na, K, P, COD, BOD 5, CT, CTT and E. coli showed no statistically significant differences. The OD showed significant. The N, much significance and the pH, extreme statistical significance. The filters reduced the concentrations of nutrients, organic matter and pathogenic microorganisms, but with reduced flickers adopted times could not find statistical differences between treatments. These values were not compatible with those recommended for agricultural use, according to CONAMA resolution. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/667
dc.date.accessioned 2018-05-14T19:03:21Z
dc.date.available 2018-05-14
dc.date.available 2018-05-14T19:03:21Z
dc.type Dissertação pt_BR
dc.subject Esgoto doméstico pt_BR
dc.subject Filtro intermitente de areia pt_BR
dc.subject Água residuária doméstica pt_BR
dc.subject Fluxo descendente intermitente pt_BR
dc.subject Pós-tratamento de efluente pt_BR
dc.subject Tanque séptico pt_BR
dc.subject Post-treated domestic wastewater pt_BR
dc.subject Domestic wastewater pt_BR
dc.subject Septic tank pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SOUSA, Eliana Pereira de.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Quality study of post-treated domestic wastewater in flow down flashing. pt_BR
dc.identifier.citation SOUSA, Eliana Pereira de. Estudo da qualidade de água residuária doméstica pós-tratada em fluxo descendente intermitente. 2015. 93f. . (Dissertação de Mestrado Profissional), Programa de Pós-graduação em Sistemas Agroindustriais, Centro de Ciências e Tecnologia Agroalimentar, Universidade Federal de Campina Grande – Pombal – Paraíba – Brasil, 2015. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta