DSpace/Manakin Repository

Sinterização de cerâmicas feldspáticas odontológicas utilizando energia de micro-ondas.

Mostrar registro simples

dc.creator.ID MEDEIROS, F. D. S. C. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/0015458283423542 pt_BR
dc.contributor.advisor1 MENEZES, Romualdo Rodrigues.
dc.contributor.advisor1ID MENEZES, R. R. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/1169292996645931 pt_BR
dc.contributor.advisor-co1 SANTANA, Lisiane Navarro de Lima.
dc.contributor.advisor-co1ID SANTANA, L. N. L.
dc.contributor.advisor-co1ID http://lattes.cnpq.br/4057799848801141
dc.contributor.referee1 NEVES, Gelmires de Araújo.
dc.contributor.referee2 CARTAXO, Juliana de Melo.
dc.contributor.referee3 DUARTE, Rosângela Marques.
dc.description.resumo Cerâmicas odontológicas são materiais conhecidos na odontologia por sua elevada dureza, biocompatibilidade e excelentes propriedades ópticas, que as tornam capazes de reproduzir artificialmente os dentes naturais. Estes materiais são sinterizados em fornos de queima rápida convencional em elevadas temperaturas e com rápidas taxas de aquecimento. A utilização da energia de microondas no aquecimento destes materiais é algo novo, sendo comprovada escassez de estudos na literatura. O objetivo deste trabalho foi avaliar e comparar propriedades e características de cerâmicas odontológicas de cobertura sinterizadas em forno convencional e através de energia de microondas. Neste estudo foram utilizadas cinco porcelanas dentárias: EX-3 (Noritake), Starlight Ceram (Dentsply), VMK 95, VM 7, e VM 13 (Vita) que foram inicialmente caracterizadas através das técnicas de difração de raio X (DRX), espectometria de fluorescência, granulometria a laser e microscopia eletrônica de varredura (MEV). Em seguida foram confeccionados corpos de prova de cada material (n=30), segundo a normalização ISO 6872 e indicações do fabricante. Dez corpos de prova foram sinterizados de forma convencional e os outros 20 sinterizados através de energia de microondas, sendo 10 sinterizados em um tempo estabelecido como ideal para cada material, e os outros 10 subdividos em dois grupos de 5 e sinterizados com variação de um minuto a menos e um minuto a mais. Em seguida, os corpos de prova foram submetidos à caracterização física e mecânica através de determinação da absorção de água, densidade e porosidade aparente, resistência à flexão e microdureza Vickers. A identificação de fases e características microestruturais dos materiais sinterizados foi realizada através de DRX e MEV, respectivamente. Os resultados foram submetidos a Análise de Variância (ANOVA), Teste de Tukey e Teste t, ao nível de 5% de probabilidade. Os resultados entre os tipos de sinterização (convencional e microondas no tempo ideal) mostraram para as cerâmicas EX-3, VMK 95 e VM7 valores de absorção de água e porosidade aparente semelhantes entre si, porém os valores de densidade aparente destes materiais foram significativamente maiores para sinterização convencional. Os valores de resistência à flexão e microdureza Vickers dos materiais avaliados foram semelhantes entre si (p<0,05), exceto a cerâmica EX-3 que apresentou melhor desempenho na sinterização convencional para resistência à flexão. Os materiais sinterizados através de energia de microondas com variação de tempo mostrou comprometimento de propriedades físicas e mecânicas. As análises dos materiais sinterizados através de DRX e MEV evidenciaram diferenças microestruturais entre os tipos de sinterização avaliados para todos os materiais. Pode-se concluir que a sinterização através de energia de microondas produziu peças com propriedades mecânicas similares àquelas obtidas pela sinterização convencional. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Ciências e Tecnologia - CCT pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM CIÊNCIA E ENGENHARIA DE MATERIAIS pt_BR
dc.publisher.initials UFCG pt_BR
dc.title Sinterização de cerâmicas feldspáticas odontológicas utilizando energia de micro-ondas. pt_BR
dc.date.issued 2013-02-28
dc.description.abstract Dental porcelains are known in dentistry due to high hardness, biocompatibility and excellent optical properties, which make them able to artificially reproduce the natural teeth. These materials are sintered in the conventional fast firing furnace at high temperatures and faster heating rates. The possibility of the microwave processing for heating these materials is something new, and proven lack of research in the literature. The purpose of this study was to evaluate and compare microstructure, mechanical and physical properties obtained by dental porcelains sintering in a conventional furnace versus microwave furnace. Five coverage dental porcelains were selected: EX-3 (Noritake), Starlight Ceram (Dentsply), VMK 95, VM 7, and VM 13 (Vita) that were characterized for X-ray diffraction (XRD), fluorescence spectrometry, granulometry and scanning electron microscopy (SEM). Thirty specimens of each material were prepared, according to ISO 6872 and directions of the manufacturer. Ten specimens were sintered in a conventional furnace and 20 sintered using microwave energy, which 10 sintered at a time established as optimal for each material, and the remaining 10 subdivided into two groups which five were sintered with variation less than one minute and one more minute. The specimens were submitted to physical and mechanical tests of determining water absorption, apparent density and porosity, flexural strength and Vickers microhardness. The phase composition was examined by using X-ray diffraction and microstructure characteristics were studied with scanning electron microscopy. Data were statistically analyzed using ANOVA, Tukey's test (α=0.05) and independent t test (α=0.05). The results of water absorption and apparent porosity showed similar values between conventional and optimal microwave sintering for the groups: EX-3, VMK 95 and VM7, however significant differences for the groups: Starlight ceram and VM 13. No significant differences for microhardness and flexural strength were found, except for EX-3 group flexural strength which was higher for conventional sintering. Microstructural differences between the types of microwave sintering were examined with scanning electron microscopy and XRD. The results showed that microwave sintering produced specimens with mechanical properties similar to those obtained by conventional sintering. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/7189
dc.date.accessioned 2019-09-20T14:10:41Z
dc.date.available 2019-09-20
dc.date.available 2019-09-20T14:10:41Z
dc.type Tese pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator SILVA, Fábia Danielle Sales Cunha Medeiros.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Sintering of dental feldspar ceramics using microwave energy. pt_BR
dc.identifier.citation SILVA, Fábia Danielle Sales Cunha Medeiros e. Sinterização de cerâmicas feldspáticas odontológicas utilizando energia de micro-ondas. 2013. 103 f. (Tese de Doutorado em Ciência e Engenharia de Materiais), Programa de Pós-graduação em Ciência e Engenharia de Materiais, Centro de Ciências e Tecnologia, Universidade Federal de Campina Grande - Paraíba - Brasil, 2013. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/7189 pt_BR