DSpace/Manakin Repository

Avaliação da adesão de profissionais da saúde às medidas de prevenção de infecção de corrente sanguínea relacionada ao cateter central.

Mostrar registro simples

dc.creator.ID DANTAS, G. D. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/8381149873275882 pt_BR
dc.contributor.advisor1 FIGUEIREDO, Danielle Samara Tavares de Oliveira .
dc.contributor.advisor1ID FIGUEIREDO, D.S.T.O. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/5852668941136839 pt_BR
dc.contributor.advisor2ID FIGUEIREDO, D.S.T.O. pt_BR
dc.contributor.referee1 PIMENTEL, Edlene Régis Silva.
dc.contributor.referee2 NOBRE, Amanda Manuella Dantas.
dc.description.resumo As infecções de corrente sanguínea caracterizam-se como um problema importante de segurança do paciente, principalmente nas Unidades de Terapia Intensiva, devido à realização de inúmeros procedimentos invasivos, com destaque para o uso do cateter venoso central (CVC). Objetivo: Avaliar a adesão dos profissionais da saúde às medidas de prevenção de infecções de corrente sanguínea relacionadas ao cateter venoso central (ICSR-CVC) em Unidades de Terapia Intensiva. Métodos: Estudo descritivo, com abordagem quantitativa, realizado na Unidade de Terapia Intensiva Adulto de um Hospital Escola em Campina Grande-PB, Brasil no período de janeiro a fevereiro de 2017. Compuseram a amostra quatro médicos, sete enfermeiros e quinze técnicos de enfermagem. A coleta de dados foi auxiliada por questionários estruturados e ocorreu em duas etapas - aplicação do instrumento aos profissionais e observação sistemática dos comportamentos do mesmos no cuidado ao paciente com CVC. A análise dos dados ocorreu mediante estatística descritiva. A pesquisa foi aprovada pelo Comitê de Ética em Pesquisa sob número de protocolo 1.869.315 conforme resolução nº 466/12. Resultados: Da equipe de enfermagem 16 (72,7%) não citaram as medidas de prevenção de ICSR-CVC recomendadas pelo Center for Desiese Control and Prevention e da Agencia Nacional de Vigilância Sanitária. No preparo de medicações, 13 (59,1%) afirmaram realizar a desinfecção de ampolas e frasco ampolas e nove (40,9%) disseram não realizar. Na administração de medicamentos, 21 (95,5%) afirmaram fazer a desinfecção do hub do cateter e um (4,5%) disse não praticar desinfecção das vias do CVC. No momento das observações, a desinfecção de ampolas e frasco ampolas não foi detectada e a desinfecção do hub do cateter também não foi visualizada. Ao serem observados durante a realização do curativo os profissionais não realizaram a higienização das mãos imediatamente antes de realizar o curativo. Com relação a equipe médica, dois (50%) não souberam citar as medidas de prevenção de ICSR-CVC, quatro (100%) citaram a veia subclávia como a de menor desenvolvimento de infecção e três (33,3%) mencionaram o S. aureus como principal microorganismo envolvido nas ICSR-CVC. Para realizar a inserção do CVC, três (75%) participantes da equipe médica disseram que lavam as mãos com água e sabão antes e um (33,3%) afirmou que além da higienização, realiza a fricção com álcool a 70%. Quanto as principais dificuldades que podem estar prejudicando as boas práticas na inserção e manuseio de CVC destacam-se as dúvidas de cunho teórico apresentadas pela equipe de enfermagem e o desconhecimento dos protocolos desenvolvidos pelo CDC e ANVISA por ambas as equipes. Conclusão: Conclui-se que a equipe de enfermagem participante desse estudo possui fragilidades na adesão às medidas de prevenção de ICSR-CVC. Não é possível descrever a adesão da equipe médica visto que não foi possível visualizar os momentos de inserção de CVC. Entretanto, ambas as equipes demonstraram possuir conhecimentos parciais acerca das medidas de prevenção de ICSR-CVC preconizadas pela ANVISA e CDC. Esses achados remetem a importância da implementação de intervenções educativas para a prevenção de ICSR-CVC para ambas as equipes no setor. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Educação e Saúde - CES pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Enfermagem de Saúde Pública pt_BR
dc.title Avaliação da adesão de profissionais da saúde às medidas de prevenção de infecção de corrente sanguínea relacionada ao cateter central. pt_BR
dc.date.issued 2017-03-24
dc.description.abstract Bloodstream infections are characterized as an important patient safety problem, especially in the Intensive Care Units, due to numerous invasive procedures, especially the use of the central venous catheter (CVC). Objective: To evaluate the adherence of health professionals to measures of prevention of central venous catheter-related infections (ICSR-CVC) in Intensive Care Units. Methods: This was a descriptive study, with a quantitative approach, carried out at the Adult Intensive Care Unit of the Alcides Carneiro University Hospital of the Federal University of Campina Grande, Campina Grande, Brazil, from January to February 2017. Four physicians, seven Nurses and fifteen nursing technicians. The data collection was aided by structured questionnaires and occurred in two stages - application of the instrument to the professionals and systematic observation of the behaviors of the same one in the care to the patient with CVC. Data analysis was performed using descriptive statistics. The research was approved by the Research Ethics Committee under protocol number 1,869,315 according to resolution nº 466/12. Results: Of the nursing team 16 (72.7%), they did not mention the measures of prevention of SCI-CVC recommended by the Center for Desertion Control and Prevention and of the National Agency of Sanitary Surveillance. In the preparation of medications, 13 (59.1%) reported disinfecting ampoules and vials and nine (40.9%) said they did not perform. In drug administration, 21 (95.5%) reported disinfecting the catheter hub and one (4.5%) said they did not disinfect the CVC pathways. At the time of observation, disinfection of ampoules and vial ampoules was not detected and disinfection of the catheter hub was also not visualized. When they were observed during the dressing, the professionals did not perform the hygiene of the hands immediately before performing the dressing. With regard to the medical team, two (50%) did not mention the ICSR-CVC prevention measures, four (100%) cited the subclavian vein as the one with the lowest infection development and three (33.3%) mentioned S . Aureus as the main microorganism involved in ICSR-CVC. In order to perform the CVC insertion, three (75%) participants of the medical team said that they washed their hands with soap and water before and one (33.3%) stated that besides the hygienization, it performs friction with alcohol at 70%. The main difficulties that may be hindering good practices in the insertion and manipulation of CVC are the theoretical doubts presented by the nursing team and the lack of knowledge of the protocols developed by CDC and ANVISA by both teams. Conclusion: It was concluded that the nursing team participating in this study has weaknesses in adherence to the measures of prevention of CVS-ICSR. It is not possible to describe the adhesion of the medical team since it was not possible to visualize the moments of insertion of CVC. However, both teams demonstrated partial knowledge about the measures of prevention of CVS-CVS advocated by ANVISA and CDC. These findings point to the importance of the implementation of educational interventions for the prevention of ICSR-CVC for both teams in the sector. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/7563
dc.date.accessioned 2019-10-01T12:05:31Z
dc.date.available 2019-10-01
dc.date.available 2019-10-01T12:05:31Z
dc.type Trabalho de Conclusão de Curso pt_BR
dc.subject Unidades de terapia intensiva pt_BR
dc.subject Infecção hospitalar pt_BR
dc.subject Infecções relacionadas a cateter pt_BR
dc.subject Cateterismo venoso central pt_BR
dc.subject Segurança do paciente pt_BR
dc.subject Intensive care units pt_BR
dc.subject Hospital infection pt_BR
dc.subject Catheter-related infections pt_BR
dc.subject Central venous catheterization pt_BR
dc.subject Patient safety pt_BR
dc.subject Unidades de cuidados intensivos
dc.subject Infección hospitalaria
dc.subject Infecciones relacionadas con el catéter
dc.subject Seguridad del paciente
dc.rights Acesso Aberto pt_BR
dc.creator DANTAS, Gisele Dias.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation of adherence of health professionals to measures to prevent central catheter-related bloodstream infection. pt_BR
dc.title.alternative Evaluación de la adherencia de los profesionales de la salud a las medidas de prevención de la infección del torrente sanguíneo relacionada con los catéteres centrales.
dc.identifier.citation DANTAS, Gisele Dias. Avaliação da adesão de profissionais da saúde às medidas de prevenção de infecção de corrente sanguínea relacionada ao cateter central. 2017. 72 fl. (Trabalho de Conclusão de Curso – Monografia), Curso de Bacharelado em Enfermagem, Centro de Educação e Saúde, Universidade Federal de Campina Grande, Cuité – Paraíba – Brasil, 2017. pt_BR
dc.description.resumen Las infecciones del torrente sanguíneo se caracterizan por ser un problema importante de seguridad del paciente, especialmente en las Unidades de Cuidados Intensivos, debido al desempeño de numerosos procedimientos invasivos, con énfasis en el uso de catéter venoso central (CVC). Objetivo: Evaluar la adherencia de los profesionales de la salud a las medidas para prevenir Infecciones del torrente sanguíneo relacionadas con el catéter venoso central (ICSR-CVC) en Unidades de cuidados intensivos. Métodos: Estudio descriptivo con enfoque cuantitativo, realizado en la Unidad de Cuidados Intensivos de Adultos de un Hospital Docente de Campinas Grande-PB, Brasil en el período de enero a febrero de 2017. La muestra estuvo compuesta por cuatro médicos, siete enfermeras y quince técnicos de enfermería. Se ayudó a la recopilación de datos mediante cuestionarios estructurados y se produjo en dos etapas: la aplicación del instrumento a profesionales y la observación sistemática de su comportamiento en el cuidado del paciente con CVC. El análisis de los datos se realizó mediante estadística descriptiva. La búsqueda fue aprobado por el Comité de Ética en Investigación con el número de protocolo 1.869.315 según Resolución No. 466/12. Resultados: Del equipo de enfermería, 16 (72,7%) no mencionaron la Medidas de prevención ICSR-CVC recomendadas por el Center for Desiese Control y Prevención y Agencia Nacional de Vigilancia Sanitaria. En la preparación de medicamentos, 13 (59,1%) declararon que realizaron la desinfección de ampollas y ampollas y nueve (40,9%) dijo que no actuara. En la administración de medicamentos, 21 (95,5%) afirmaron que estaban desinfección del conector del catéter y uno (4,5%) dijo que no practicaba la desinfección de las vías del CVC. En el momento de las observaciones, no se detectó la desinfección de ampollas y ampollas de viales y Tampoco se visualizó la desinfección del conector del catéter. Cuando se observa durante el vistiendo a los profesionales no realizaron higiene de manos de forma inmediata antes de aplicar el apósito. En cuanto al equipo médico, dos (50%) no pudieron nombrar el Medidas de prevención ICSR-CVC, cuatro (100%) citaron la vena subclavia como el menor desarrollo de la infección y tres (33,3%) mencionaron S. aureus como el principal microorganismo involucrado en ICSR-CVC. Para realizar la inserción CVC, tres (75%) Los participantes del personal médico dijeron que se lavan las manos con agua y jabón antes y (33,3%) afirmó que además de limpiar, también se frota con alcohol al 70%. En cuanto a principales dificultades que pueden estar obstaculizando las buenas prácticas en la inserción y manipulación de CVC, las dudas teóricas planteadas por el personal de enfermería y el desconocimiento de los protocolos desarrollados por los CDC y ANVISA por ambos equipos. Conclusión: Se concluye que el equipo de enfermería que participa en este estudio ha debilidades en la adherencia a las medidas de prevención ICSR-CVC. No es posible describir el adherencia del equipo médico ya que no fue posible visualizar los momentos de inserción de CVC. Sin embargo, ambos equipos demostraron tener un conocimiento parcial sobre el Medidas de prevención ICSR-CVC recomendadas por ANVISA y CDC. estos hallazgos se refieren a la importancia de implementar intervenciones educativas para la prevención de ICSR-CVC para ambos equipos del sector.


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta