DSpace/Manakin Repository

Estudo comparativo dos métodos contínuo e semicontínuo de determinação da taxa de consumo de oxigênio.

Mostrar registro simples

dc.creator.ID SANTOS, S. L. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/3125071417158010 pt_BR
dc.contributor.advisor1 HAANDEL, Adrianus Cornelius Van.
dc.contributor.advisor1ID HAANDEL, A. C. V. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4982723988716062 pt_BR
dc.contributor.referee1 OLIVEIRA, Rui de.
dc.contributor.referee2 PAIVA, Francisco Vieira.
dc.description.resumo A respirometria é utilizada em sistemas aeróbios de tratamento de águas residuárias para determinar a Taxa de Consumo de Oxigênio (TCO) pela massa de lodo bacteriano. Em princípio há dois métodos experimentais que se aplicam à determinação da TCO: o método semicontínuo muito atrativo pela sua praticidade e facilidade na execução dos testes, porém não é um método que possa de fato ser aplicado em sistemas operando em escala real, e o método contínuo, ainda em fase experimental, mas muito atrativo porque pode fornecer uma medida contínua da TCO. Dessa forma, visando contribuir para a aplicação mais efetiva da respirometria em sistemas de lodo ativado, foi realizado um estudo comparativo entre os dois métodos de determinação da TCO que teve como principal objetivo estabelecer o limite da aplicabilidade do método contínuo da TCO sob condições de repentinas variações da TCO com o tempo. Também foram avaliados os fatores que interferem na constante de transferência de oxigênio: concentração de lodo, surfactantes e temperatura, uma vez que esta se constitui como parâmetro fundamental para a aplicabilidade do método contínuo. O método semicontínuo consiste na definição de referências da concentração de oxigênio superior (ODmáx) e inferior (ODmin). Atingido o valor de ODmáx a aeração é interrompida e observada a diminuição da concentração de oxigênio devida ao consumo pelos microrganismos que é medida em função do tempo. Quando a referência inferior é alcançada o valor da TCO é calculado e inicia-se um novo ciclo. A TCO é a razão entre a diminuição da concentração de OD e o tempo necessário para ocorrer esta diminuição. O método contínuo se baseia na aplicação de aeração continuamente no reator e na observação da concentração do Oxigênio Dissolvido (OD) em função do tempo. Pela aplicação de uma equação simples é possível estimar os dados da TCO a partir do perfil do OD com o tempo, se a constante de transferência de oxigênio (Kla) for conhecida. Os resultados experimentais obtidos mostram boa precisão e acurácia para os dados obtidos pelos dois métodos. A análise estatística (ANOVA) aplicada a um nível de significância de 5% não mostrou diferença significativa entre os métodos testados, sendo então viável a sua aplicação. Diante desses resultados torna-se claro que a escolha do método a ser utilizado fica a critério do usuário. O método semicontínuo é mais facilmente aplicável e dá respostas mais rápidas, é uma boa alternativa para o desenvolvimento de ensaios laboratoriais e em pequena escala, mas não se aplica de maneira rotineira em sistemas em escala real. Se a finalidade é monitoração e operação de estações de tratamento de esgoto em escala real o método contínuo deve ser aplicado. De maneira geral as variáveis testadas para avaliar a influência da concentração de lodo, não mostraram condições que inviabilizassem a aplicabilidade do método contínuo, no entanto vale ressaltar que este é um estudo voltado para as condições da água residuária de Campina Grande podendo apresentar características diferenciadas em outros locais. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Civil e Ambiental
dc.title Estudo comparativo dos métodos contínuo e semicontínuo de determinação da taxa de consumo de oxigênio. pt_BR
dc.date.issued 2013-02-20
dc.description.abstract Respirometry is used in aerobic waste water treatment systems to determine the Oxygen Uptake Rate (OUR) by the bacterial sludges mass. In principle there are two experimental methods available that can be applied to determine the OUR: The semi continuous and the continuous method. The semi continuous method is attractive because of its practicality and its simplicity, but it cannot be applied routinely in full scale systems. The continuous method is not yet established but it can in principle it can furnish a continuous measurement of OUR in full scale systems. In an attempt to contribute to a more effective application of respirometry in full scale activated sludges systems, a comparative study was carried out with the two methods to determine the OUR. The study has as its main objective to establishe the limit of applicability of the continuous method when conditions were imposed of sudden and large variations of the OUR with time. Also experiments were carried out to determine the influence of several factors on the oxygen transfer constant: sludges concentration, surfactants and temperature. Knowledge of the value of the oxygen transfer constant is necessary to apply the continuous method form determination of OUR. The semi continuous method consists of defining of upper and lower set points of dissolved oxygen in the mixed liquor (ODmáx and (ODmin) respectively. When the ODmáx value is reached the aeration of the system is interrupted and the consequential decrease of the OD concentration as a consequence of the consumption by the microorganisms is observed as a function of time. When the lower set point is reached the OUR value is calculated and a new cycle is initiated. OUR is the ratio between the OD decrease and the time required for this decrease to take place. When the continuous method is used the aeration is constant and the OUR is calculated from variations of the DO concentration with time. For the calculation it is necessary that the oxygen transfer constant of the aeration system is known. The obtained experimental results show good precision and accuracy of the data obtained with both methods, since a statistical analysis with (ANOVA) applied at a significance level of 5% did not reveal significant differences in the obtained results with the two methods. Thus both methods may be applied in practice. With the obtained result it is clear that the choice of which method is to be used in a particular situation depends on the user of the respirometer. The semi continuous method is easier to apply and gives results more readily. It is a good alternative for small scale laboratory or pilot plant tests, but it cannot be applied routinely in full scale systems. If monitoring of systems operating at full scale is the aim, the continuous method must be preferred. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8131
dc.date.accessioned 2019-10-16T13:04:08Z
dc.date.available 2019-11-16
dc.date.available 2019-10-16T13:04:08Z
dc.type Dissertação pt_BR
dc.subject Gestão de Recursos Hídricos
dc.subject Tratamento de Águas Residuárias
dc.subject Respirometria
dc.subject Taxa de Consumo de Oxigênio
dc.subject Constante de Transferência de Oxigênio
dc.subject Método Contínuo
dc.subject Método Semicontínuo
dc.subject Water Resources Management
dc.subject Wastewater Treatment
dc.subject Respirometry
dc.subject Oxygen Consumption Rate
dc.subject Oxygen Transfer Constant
dc.subject Semi-continuous Method
dc.subject Continuous Method
dc.rights Acesso Aberto pt_BR
dc.creator SANTOS, Silvânia Lucas dos.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Comparative study of continuous and semicontinuous methods of determination of oxygen consumption rate. pt_BR
dc.identifier.citation SANTOS, Silvânia Lucas dos. Estudo comparativo dos métodos contínuo e semicontínuo de determinação da taxa de consumo de oxigênio. 2013. 113f. (Dissertação) Mestrado em Engenharia Civil e Ambiental, Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Campina Grande - Paraíba - Brasil, 2013. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8131 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta