DSpace/Manakin Repository

Avaliação do uso de poliamida monofilamentar em trabalhos de instalações energizadas.

Mostrar registro simples

dc.creator.ID GOMES, A. M. M .B. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/9185786028228628 pt_BR
dc.contributor.advisor1 COSTA, Edson Guedes da.
dc.contributor.advisor1ID COSTA, E. G. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3930289115658143 pt_BR
dc.contributor.referee1 LIRA, George Rossany Soares de.
dc.contributor.referee2 FERREIRA, Tarso Vilela.
dc.contributor.referee3 NEVES, Washington Luiz Araujo.
dc.description.resumo Este trabalho apresenta os ensaios realizados em laboratório e os testes de campo de linha de mão isolante. Utilizou-se nos experimentos monofilamentos de 3 a 6 mm de poliamida com o objetivo de aplicá-las em trabalhos com instalações energizadas como, por exemplo, linha de transmissão de 500 kV e subestações de 230 kV. Originalmente, o monofilamento é usado em pescaria ou roçadeira. Com o uso da linha de mão isolante os trabalhos em instalações energizadas são facilitados, com diminuição de tempo e esforço, sem contar com aumento da segurança no processo, tanto do ponto de vista das instalações como da segurança do pessoal envolvido. Para avaliar o desempenho elétrico das linhas de mão foram realizados ensaios de suportabilidade elétrica, com medição da corrente de fuga. Amostras novas e envelhecidas foram ensaiadas. Para efeito comparativo, nos ensaios nas linhas de mão utilizou-se a mesma metodologia consagrada aplicada aos bastões isolantes. Os resultados se mostraram promissores para trabalhos com instalações energizadas, apresentando desempenho satisfatório do ponto de suportabilidade elétrica, mesmo quando comparada aos consagrados bastões isolantes. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica
dc.subject.cnpq Linhas de Transmissão
dc.subject.cnpq Manutenção em Instalação Energizada
dc.subject.cnpq Linha de Mão Isolante
dc.title Avaliação do uso de poliamida monofilamentar em trabalhos de instalações energizadas. pt_BR
dc.date.issued 2014-05-08
dc.description.abstract This paper presents the tests performed in insulated hand line, in laboratory and field. It was used in the experiments the monofilament 3-6 mm polyamide line, aiming to be applied in energized facilities, such as: 500 kV transmission lines and 230 kV substations. Originally, the monofilament is used in fishing or mowing .The application of the insulated hand line on energized facilities increases the productivity, due to reduction of time and effort of the linemen, not to mention the higher level of safety in the process. To evaluate the electrical performance of insulated hand lines withstand electrical testing, the measurement of the leakage current were performed. New and aged samples were tested. For comparative purpose, the methodology used for the tests in insulated hand lines were the same as used for live line tools, such as hot sticks. The results were promising to work on energized facilities, showing satisfactory performance concerning to the electrical withstand, even when compared with the established tests of hot sticks. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/8293
dc.date.accessioned 2019-10-21T21:18:47Z
dc.date.available 2019-10-21
dc.date.available 2019-10-21T21:18:47Z
dc.type Dissertação pt_BR
dc.subject Linhas de Transmissão
dc.subject Manutenção em Instalação Energizada
dc.subject Linha de Mão Isolante
dc.subject Instalações Energizadas
dc.subject Distância de Segurança
dc.subject Esfera de Sinalização
dc.subject Transmission lines
dc.subject Maintenance in Energized Installation
dc.subject Insulating Hand Line
dc.subject Energized Installations
dc.subject Safety Distance
dc.subject Signaling Sphere
dc.rights Acesso Aberto pt_BR
dc.creator GOMES, Alexandre Manoel de Medeiros Borja.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Evaluation of the use of monofilament polyamide in works of energized installations. pt_BR
dc.identifier.citation GOMES, Alexandre Manoel de Medeiros Borja. Avaliação do uso de poliamida monofilamentar em trabalhos de instalações energizadas. 2014. 149f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2014. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples