DSpace/Manakin Repository

Análise da sensibilidade de acopladores direcionais microstrip na medição de descargas parciais em uma bobina de hidrogerador.

Mostrar registro simples

dc.creator.ID QUELEMES, P. V. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/7205334140057870 pt_BR
dc.contributor.advisor1 COSTA, Edson Guedes da.
dc.contributor.advisor1ID COSTA, E. G. pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/3930289115658143 pt_BR
dc.contributor.referee1 FREIRE, Raimundo Carlos Silvério.
dc.contributor.referee2 FERREIRA, Tarso Vilela.
dc.description.resumo Neste trabalho é realizado um estudo, com base em dados experimentais, para a análise da sensibilidade de acopladores direcionais microstrip como sensores para medição de descargas parciais em uma bobina de hidrogerador. Para isso, foram confeccionadoscquatro acopladores direcionais microstrip e, através de testes realizados em laboratório, avaliou-se a aplicabilidade dos acopladores na detecção de pulsos eletromagnéticos provenientes de descargas parciais. Como forma de validar as medições de descargas parciais obtidas pelo acoplador de melhor sensibilidade, utilizou-se outros dois sensores: um transformador de corrente de alta frequência (High Frequency Current Transformer - HFCT) e um capacitor de acoplamento de 1000 pF. A aquisição dos dados foi realizada com um osciloscópio digital de quatro canais e o processamento dos dados com o software Matlab®. A avaliação das medições obtidas nos experimentos foi feita por meio da relação sinal-ruído (RSR), pela contagem do número de pulsos detectados e a verificação dos padrões representados em função da tensão aplicada, método conhecido por PRPD (Phase Resolved Partial Discharge). Os resultados obtidos em laboratório demonstraram que o acoplador direcional microstrip proposto pode ser aplicado, como sensor, para a medição de descargas parciais em uma bobina de hidrogerador. O mesmo consiste em uma solução viável, de baixo custo de fabricação e com uma ótima sensibilidade. No entanto, para validar a aplicação do sensor proposto, ainda é necessário um estudo mais aprofundado, considerando todas as implicações decorrentes de sua instalação em um hidrogerador real, bem como o ambiente em que estará inserido. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica
dc.title Análise da sensibilidade de acopladores direcionais microstrip na medição de descargas parciais em uma bobina de hidrogerador. pt_BR
dc.date.issued 2016-03-21
dc.description.abstract In this work is realized a study based on experimental data, for analyzing the sensitivity microstrip directional couplers as sensors for measuring partial discharges in a hydro generator coil. To do so, four microstrip directional couplers were fabricated and through laboratory tests, we evaluated the applicability of these couplers for detecting electromagnetic pulses originating from partial discharges. In order to validate the measurements obtained by the partial discharges coupler better sensitivity, we used two sensors: a high frequency current transformer (HFCT) and a coupling capacitor 1000 pF. Data acquisition was performed with a digital oscilloscope four channels and data processing with the Matlab® software. The evaluation of the measurements obtained in the experiments was performed by the signal-to-noise ratio (SNR), the number of detected pulses counting and checking of the patterns plotted against the applied voltage, known method PRPD (Phase Resolved Partial Discharge). The results obtained in our laboratory demonstrated that the microstrip directional coupler proposed can be applied as a sensor for measuring partial discharges in a hydro generator coil. The same consists of a viable solution, with low manufacturing cost and a great sensitivity. However, to validate the application of the proposed sensor, a further study is still needed, considering all the implications of his installation in a real hydro generator, as well as the environment in which will be inserted. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9435
dc.date.accessioned 2019-11-22T20:41:12Z
dc.date.available 2019-11-22
dc.date.available 2019-11-22T20:41:12Z
dc.type Dissertação pt_BR
dc.rights Acesso Aberto pt_BR
dc.creator QUELEMES, Patrese Veras.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Sensitivity analysis of microstrip directional couplers in the measurement of partial discharges in a hydrogenerator coil. pt_BR
dc.identifier.citation QUELEMES, Patrese Veras. Análise da sensibilidade de acopladores direcionais microstrip na medição de descargas parciais em uma bobina de hidrogerador. 2016. 102f. (Dissertação) Mestrado em Engenharia Elétrica), Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática , Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2016. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta