dc.description.resumo Para a medição de grandezas físicas, como radiação, H, velocidade de fluidos, v e temperatura, Ta, existem configurações que se baseiam em sensores termorresistivos, utilizando o princípio da equivalência elétrica. Dentre as arquiteturas clássicas, que apresentam melhor resposta em frequência e utilizam este princípio, a mais comum é a que utiliza um sensor termorresistivo aquecido à uma temperatura constante. O sensor é aquecido por efeito Joule, à uma temperatura previamente determinada, e a variação da radiação térmica incidente, velocidade do fluido ou temperatura do meio é compensada variando-se o aquecimento elétrico devido à realimentação negativa utilizada, mantendo o sensor à uma temperatura quase constante. Neste trabalho é proposta uma arquitetura alternativa em que se faz constante a diferença de temperatura entre o sensor e o ambiente. Para ambas as configurações neste trabalho desenvolveram-se expressões e realizaram-se simulações para o sinal de saída em função da grandeza de entrada e da sensibilidade de arquiteturas com saídas analógicas e pulsadas (moduladas em duração de pulso - PWM), para sensores dos tipos PTC e NTC. Foram feitas comparações entre as arquiteturas, verificando-se que as arquiteturas com diferença de temperatura constante, saída analógica e com sensor termorresistivo do tipo PTC tinham melhor desempenho em relação à sensibilidade relativa, menor influência da grandeza interferente e maior influência da grandeza de entrada. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Engenharia Elétrica e Informática - CEEI pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Elétrica
dc.title Radiômetro solar de equivalência elétrica com sensor aquecido à diferença de temperatura constante. pt_BR
dc.date.issued 2015-03
dc.description.abstract For the measurement of physical quantities, such as radiation, H, velocity fluids, v, and temperature, Ta, there are settings based on thermoresistive sensors, which use the principle of electrical equivalence. Among the classic architectures, which have better frequency response and use this principle, the most common is the one that uses a thermoresistive sensor heated to a constant temperature. The sensor is heated by Joule effect to a previously stipulated temperature, and the variation of thermal radiation, temperature or flow velocity of the medium is compensated by varying the electric heating due to the negative feedback used, maintaining the sensor at an almost constant temperature. In this work it is proposed an alternative architecture that makes constant the temperature difference between the sensor and the environment. For both configurations, in this work, were developed expressions and simulations held for the output signal as a function of the input and the sensitivity of architecture with analog outputs and pulsed (modulated pulse duration - PWM) for sensors types of PTC and NTC. Comparisons were made between the architectures, verifying that architectures with constant temperature difference, analog output and thermoresistive sensor PTC had better performance with respect to the sensitivity, the less influence of interfering variable and the greater influence of input variable. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9572
dc.date.accessioned 2019-11-27T10:09:08Z
dc.date.available 2019-11-27
dc.date.available 2019-11-27T10:09:08Z
dc.type Dissertação pt_BR
dc.subject Sensor Termorresistivo
dc.subject Sensibilidade
dc.subject Radiação Solar
dc.subject Termistor
dc.subject Radiômetro Solar
dc.subject Equivalência Elétrica
dc.subject Thermoresistive Sensor
dc.subject Sensitivity
dc.subject Solar Radiation
dc.subject Thermistor
dc.subject Solar Radiometer
dc.subject Electrical Equivalence
dc.rights Acesso Aberto pt_BR
dc.creator LOBO, Petrov Crescencio.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Solar equivalence solar radiometer with heated sensor at constant temperature difference. pt_BR
dc.identifier.citation LOBO, Petrov Crescencio. Radiômetro solar de equivalência elétrica com sensor aquecido à diferença de temperatura constante. 2015. 106f. (Dissertação) Mestrado em Engenharia Elétrica, Programa de Pós-Graduação em Engenharia Elétrica, Centro de Engenharia Elétrica e Informática, Universidade Federal de Campina Grande – Campina Grande - Paraíba - Brasil, 2015. pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta