dc.description.resumo |
0 principio do funcionamento de sistemas aeróbios de tratamento de águas
residuárias consiste em manter uma população bacteriana no sistema e fornecer
oxigênio em quantidade suficiente para que esta massa bacteriana possa metabolizar o
material orgânico presente no afluente (Van Haandel e Marais, 1999). Na maioria dos
sistemas aeróbios o oxigênio e transferido da atmosfera para a fase liquida do sistema de
tratamento por meio de aeradores mecânicos que normalmente funcionam com motores
elétricos. Para manter a população bacteriana viva e com boa capacidade metabólica a
disponibilidade de oxigênio e necessária. Contudo, na pratica pode-se haver interrupção
da aeração, seja por problemas ocasionais no fornecimento da energia elétrica ou devido
a interrupções planejadas em horários de preço elevado de energia elétrica. Por outro
lado, e possível que durante determinados períodos não haja carga orgânica (p.e. no
caso de não haver efluentes industriais nos fins de semana), de modo que conviria em
principio desligar os aeradores para reduzir o consumo de energia. Por esta razão, e de
interesse avaliar a influencia exercida pela interrupção da aeração na sobrevivência de
lodo ativo e sobre a atividade deste logo apos a interrupção. No presente trabalho foi
realizado um estudo da atividade e viabilidade do lodo de um sistema Bardenfho apos
período sem aeração. Para tal, foi determinada a Taxa de Consumo de Oxigênio (TCO)
na fase de respiração endógena em batelada de lodo antes e depois de se aplicar
diferentes períodos sem aeração. Determinou-se ainda a influencia da duração da
interrupção da aeração sobre a atividade das bactérias heterotróficas (que metabolizam o
material orgânico) e das autotróficas (as nitrificadoras). Para isto, determinou-se o
aumento da TCO ao se adicionar acetato de sódio e cloreto de amônia em abundancia,
substratos utilizados pelas bactérias heterotróficas e autotróficas respectivamente. Os resultados experimentais indicam que períodos de ate uma semana de interrupção da
aeração tem pouco efeito sobre a sobrevivência e sobre a atividade do lodo ativado. Para
períodos entre duas e três semanas percebeu-se uma diminuição gradual da fração de
lodo ativo, bem como da atividade metabólica dos organismos que sobreviveram.
Determinou-se ainda que tanto as bactérias heterotróficas quanto as bactérias
autotróficas (nitrificantes) preservam sua capacidade metabólica por período de ate um
mês sem aeração. Conclui-se que a massa bacteriana que se desenvolve em sistemas de
lodo ativado e capaz de resistir a períodos prolongados sem aeração. |
pt_BR |
dc.publisher.country |
Brasil |
pt_BR |
dc.publisher.department |
Centro de Tecnologia e Recursos Naturais - CTRN |
pt_BR |
dc.publisher.program |
PÓS-GRADUAÇÃO EM ENGENHARIA CIVIL E AMBIENTAL |
pt_BR |
dc.publisher.initials |
UFCG |
pt_BR |
dc.title |
Respirometria aplicada ao sistema de lodo ativado: influência de interrupções da oxigenação sobre a viabilidade e atividade do lodo ativado. |
pt_BR |
dc.date.issued |
2002-02 |
|
dc.description.abstract |
The working principle of aerobic treatment systems consists of maintaining a
bacterial population in the system and supply sufficient oxygen for the bacterial mass to
metabolise the organic matter that is present in the influent. In most aerobic systems
oxygen is transferred from the atmosphere by mechanical aerators which normally are
driven by electrical motors. The availability of oxygen is necessary in order to maintain
the bacterial mass alive and with a high metabolic capacity however in practice there
may be interruptions of the aeration due to power failures or to planned interruptions
during hours of high tariff of electrical power. On the other hand it may be possible that
there is no organic load during certain periods (for example during weekends in the case
of industrial effluents, so that in principle it would be convenient to reduce oxygen
consumption. For these reasons there is an interest to evaluate the influence of
interruptions of the aeration on the survival of activated sludge and on its activity just
after such an interruption. In this thesis a study was carried out to evaluate the feasibility
of the sludge from a Bardenpho system after periods without aeration. For this the
oxygen uptake rate (OUR) of a sludge batch was determined during the phase of
endogenous respiration before and after applying different periods without aeration.
Also the influence of the duration of the aeration interruption on the activity of the
heterotrophic bacteria (those that metabolise the organic matter) and the autotrophic
bacteria (the nitrifiers of ammonium). For this purpose, OUR was determined after
adding excess sodium acetate (for the heterotrophs) and ammonium chloride (for the
autotrophs). The experimental results indicate that interruption periods of up to one
week have little effect on the survival and the activity of activated sludge. For periods of
two to three weeks there was a gradual decrease of the active sludge mass as well as of the sludge activity of the surviving organisms. It was also established that both the
heterotrophic and the autotrophic bacteria preserve their metabolic capacity for a period
of up to one month. It is concluded that the bacterial mass that develops in the activated
sludge system is capable of withstanding long periods without aeration. |
pt_BR |
dc.identifier.uri |
http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9688 |
|
dc.date.accessioned |
2019-11-29T13:51:40Z |
|
dc.date.available |
2019-11-29 |
|
dc.date.available |
2019-11-29T13:51:40Z |
|
dc.type |
Dissertação |
pt_BR |
dc.rights |
Acesso Aberto |
pt_BR |
dc.creator |
COSTA, Adriana Guimarães. |
|
dc.publisher |
Universidade Federal de Campina Grande |
pt_BR |
dc.language |
por |
pt_BR |
dc.title.alternative |
Respirometry applied to the activated sludge system: influence of oxygenation interruptions on activated sludge viability and activity. |
pt_BR |
dc.identifier.citation |
COSTA, Adriana Guimarães. Respirometria aplicada ao sistema de lodo ativado: influência de interrupções da oxigenação sobre a viabilidade e atividade do lodo ativado. 2002. 104f. (Dissertação de Mestrado em Engenharia Civil e Ambiental), Programa de Pós-Graduação em Engenharia Civil e Ambiental, Universidade Federal de Campina Grande - Paraíba - Brasil, 2002. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9688 |
pt_BR |