DSpace/Manakin Repository

Avaliação do desempenho de um sistema de irrigação localizada utilizando águas residuárias.

Mostrar registro simples

dc.creator.ID SANTOS, C. G. F. pt_BR
dc.creator.Lattes http://lattes.cnpq.br/2167500081124483 pt_BR
dc.contributor.advisor1 LIMA, Vera Lúcia Antunes de.
dc.contributor.advisor1 HAANDEL, Adrianus Cornelius Van.
dc.contributor.advisor1 MATOS, José de Arimatéia de.
dc.contributor.advisor1ID LIMA, V. L. A. pt_BR
dc.contributor.advisor1ID HAANDEL, A. C. V.
dc.contributor.advisor1ID MATOS, J. A.
dc.contributor.advisor1Lattes http://lattes.cnpq.br/5379077061489077 pt_BR
dc.contributor.advisor1Lattes http://lattes.cnpq.br/4982723988716062
dc.contributor.referee1 HAANDEL, Adrianus Cornelius Van.
dc.contributor.referee2 SOUZA, José Luis de.
dc.contributor.referee3 DANTAS NETO, José.
dc.description.resumo Neste trabalho, avaliou-se o desempenho de um sistema experimental de irrigação localizada do tipo micro aspersão utilizando quatro tratamentos: T l - água de abastecimento, T2- água residuária tratada proveniente de um reator anaeróbio UASB usando filtro de areia e filtro de tela, T3- água residuária tratada de uma lagoa de polimento usando filtro de areia e filtro de tela e T4- água residuária tratada de uma lagoa de polimento usando filtro de disco. O sistema experimental foi montado nas dependências do PROSAB (Programa de Saneamento Básico), localizado na cidade de Campina Grande- PB. Os testes visaram a determinação dos seguintes parâmetros: coeficiente de variação de fabricação, coeficiente de uso e equação de vazão versus pressão. Foram analisados os seguintes parâmetros físico-químicos e biológicos: p l i , demanda bioquímica de oxigênio (DBO), demanda quimica de oxigênio (DQO), sólidos totais, sólidos suspensos, condutividade elétrica, turbidez, alcalinidade, clorofila "a" e algas. O desempenho do sistema foi avaliado com base nas taxas de redução dos parâmetros sólidos totais, sólidos suspensos, DBO, DQO e quantificação e identificação de algas. A vazão media dos emissores para uma pressão nominal de ISOkPa com o tratamento T l foi de 57,5 Lh~l e apos os tratamentos T2, T3 e T4 a vazão media decresceu para 54,67 Lh"1. Os resultados mostraram que com o uso de águas residuárias houve uma pequena redução na vazão dos emissores e um aumento considerável no coeficiente de variação causando uma redução na uniformidade de emissão de água. Constatou-se que com o uso de filtros de areia, filtros de tela e filtros de disco a redução no teor de matéria orgânica e algas foi muito pequena. pt_BR
dc.publisher.country Brasil pt_BR
dc.publisher.department Centro de Tecnologia e Recursos Naturais - CTRN pt_BR
dc.publisher.program PÓS-GRADUAÇÃO EM ENGENHARIA AGRÍCOLA pt_BR
dc.publisher.initials UFCG pt_BR
dc.subject.cnpq Engenharia Agrícola
dc.title Avaliação do desempenho de um sistema de irrigação localizada utilizando águas residuárias. pt_BR
dc.date.issued 2002-04
dc.description.abstract In this research, the performance of the experimental system of irrigation located type microsprinkler using four treatments : T l - water supplies, T2 - wastewater treated from UASB anaerobic reactor using sand filter and screen filter, T3 - wastewater treated from polishing pond using sand filter and screen filter and T4- - wastewater treated from polishing pond using disk filter. The experimental system was built at PROSAB (Programa de Saneamento Basieo), in Campina Grande City, Stat of Paraiba. The tests sought the determination of the following parameters: manufacturer's coefficient of variation, coefficient of use and discharge pressure head equation. That were evaluated the following parameters physicochemieal and biological: pH, biochemical oxygen demand (BOD), chemical oxygem demand (COD), total solids (TS), suspended solids (SS), electrical conductivity (EC), turbidity, alcalinity, chlorophyll a and algae. Its performance system was evaluated upon the ratios of reduction from parameters: total solids, suspended solids, BOD, COD and quantification and identification of algae. The average emitter discharge for a working pressure of ISOkPa with the treatment T l was 57,5 Lh"1 and after the treatments T2, T3 and T4 the average emitter discharge decreased for 54,67 Lh"1. The results showed that the use of wastewater caused a small reduction in the emitter discharge rate and a increase in the coefficient of variation showed one reduction in the emission uniformity. It was verified that with the use of sand filter, screen filter and disk fillter caused small reduction in the content organic matter and algae. pt_BR
dc.identifier.uri http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9777
dc.date.accessioned 2019-12-03T12:00:58Z
dc.date.available 2019-12-03
dc.date.available 2019-12-03T12:00:58Z
dc.type Dissertação pt_BR
dc.subject Sistema de Irrigação
dc.subject Águas Residuárias
dc.subject Microaspersores
dc.subject Reator UASB
dc.subject Qualidade da Água
dc.subject Digestão Anaeróbia
dc.subject Hidráulica dos Emissores
dc.subject Irrigation System
dc.subject Wastewater
dc.subject Micro Sprinklers
dc.subject UASB Reactor
dc.subject Water Quality
dc.subject Anaerobic Digestion
dc.subject Emitter Hydraulics
dc.rights Acesso Aberto pt_BR
dc.creator SANTOS, Cláudia Germana da Fonseca.
dc.publisher Universidade Federal de Campina Grande pt_BR
dc.language por pt_BR
dc.title.alternative Performance evaluation of a localized irrigation system using wastewater. pt_BR
dc.identifier.citation SANTOS, Cláudia Germana da Fonseca. Avaliação do desempenho de um sistema de irrigação localizada utilizando águas residuárias. 2002. 90f. (Dissertação de Mestrado em Engenharia Agrícola), Programa de Pós-Graduação em Engenharia Agrícola, Centro de Ciências e Tecnologia, Universidade Federal da Paraíba - Campus II Campina Grande - Brasil, 2002. Disponível em: http://dspace.sti.ufcg.edu.br:8080/jspui/handle/riufcg/9777 pt_BR


Arquivos deste item

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples

Buscar DSpace


Busca avançada

Navegar

Minha conta